Bedside ultrasound assessments of jugular venous compliance to track central venous pressure change during the treatment of decompensated heart failure. (25th November 2020)
- Record Type:
- Journal Article
- Title:
- Bedside ultrasound assessments of jugular venous compliance to track central venous pressure change during the treatment of decompensated heart failure. (25th November 2020)
- Main Title:
- Bedside ultrasound assessments of jugular venous compliance to track central venous pressure change during the treatment of decompensated heart failure
- Authors:
- Fatima, S
Lambert, W
Nouraie, S
Simon, M
Pacella, J - Abstract:
- Abstract: Background: Accurate volume status assessment is crucial for the treatment of acute decompensated heart failure (ADHF). Volume status assessment by physical exam is inaccurate, necessitating invasive measurement with right heart catheterization (RHC), which carries safety, pragmatic (scheduling, holding anticoagulants, etc) and financial burdens. Therefore, a reliable, non-invasive, cost-effective alternative is desired. Previously, we developed an ultrasound (US) based technique to measure internal jugular vein (IJV) compliance during RHC which was used for single time point central venous pressure (CVP) predictions. We now aim to apply this technique to track acute changes in CVP during diuresis for ADHF in patients with an in-dwelling pulmonary artery catheter. Purpose: The objective of our study was to devise a rapid, portable and reliable alternative to RHC to track acute volume changes during treatment of ADHF. Methods: We used an observational, prospective study design and recruited 15 patients from the CCU between 7/19–12/19 being treated for ADHF (systolic or diastolic) with IV diuretics +/−inotropic agents who underwent PA catheter insertion for continuous CVP monitoring. 13 of 15 patients received milrinone infusions. US images of the IJV were obtained at end expiration and during the strain phase of Valsalva at multiple 2–3 hr intervals. Change in IJV cross sectional area (ImageJ) was used as a measure of IJV compliance. Patients unable to perform theAbstract: Background: Accurate volume status assessment is crucial for the treatment of acute decompensated heart failure (ADHF). Volume status assessment by physical exam is inaccurate, necessitating invasive measurement with right heart catheterization (RHC), which carries safety, pragmatic (scheduling, holding anticoagulants, etc) and financial burdens. Therefore, a reliable, non-invasive, cost-effective alternative is desired. Previously, we developed an ultrasound (US) based technique to measure internal jugular vein (IJV) compliance during RHC which was used for single time point central venous pressure (CVP) predictions. We now aim to apply this technique to track acute changes in CVP during diuresis for ADHF in patients with an in-dwelling pulmonary artery catheter. Purpose: The objective of our study was to devise a rapid, portable and reliable alternative to RHC to track acute volume changes during treatment of ADHF. Methods: We used an observational, prospective study design and recruited 15 patients from the CCU between 7/19–12/19 being treated for ADHF (systolic or diastolic) with IV diuretics +/−inotropic agents who underwent PA catheter insertion for continuous CVP monitoring. 13 of 15 patients received milrinone infusions. US images of the IJV were obtained at end expiration and during the strain phase of Valsalva at multiple 2–3 hr intervals. Change in IJV cross sectional area (ImageJ) was used as a measure of IJV compliance. Patients unable to perform the Valsalva maneuver and on mechanical circulatory support were excluded. Results: Calculated % change in CSA of IJV was plotted against CVP. An inverse relationship was observed between CVP and % change in CSA of IJV. The data was fit with an inverse exponential regression shown in Figure 1 (R2=0.36, root mean square error = 3.19). Fivefold cross validation showed a stable model for predicting CVP based CSA (R2=0.34, root mean square error = 3.26) Conclusion: Serial portable US assessment of IJV compliance can act a surrogate measure of CVP and, therefore, can provide reliable information on acute hemodynamic changes in ADHF. Funding Acknowledgement: Type of funding source: None … (more)
- Is Part Of:
- European heart journal. Volume 41:(2020)Supplement 2
- Journal:
- European heart journal
- Issue:
- Volume 41:(2020)Supplement 2
- Issue Display:
- Volume 41, Issue 2 (2020)
- Year:
- 2020
- Volume:
- 41
- Issue:
- 2
- Issue Sort Value:
- 2020-0041-0002-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-11-25
- Subjects:
- Acute Heart Failure: Imaging
Cardiology -- Periodicals
Heart -- Diseases -- Periodicals
616.12005 - Journal URLs:
- http://eurheartj.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/ehjci/ehaa946.1220 ↗
- Languages:
- English
- ISSNs:
- 0195-668X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.717500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 26679.xml