Assessment of left ventricular filling pressure: left atrial reservoir strain is an excellent replacement for missing tricuspid regurgitation velocity. (25th November 2020)
- Record Type:
- Journal Article
- Title:
- Assessment of left ventricular filling pressure: left atrial reservoir strain is an excellent replacement for missing tricuspid regurgitation velocity. (25th November 2020)
- Main Title:
- Assessment of left ventricular filling pressure: left atrial reservoir strain is an excellent replacement for missing tricuspid regurgitation velocity
- Authors:
- Khan, F
Inoue, K
Remme, E.W
Andersen, O.S
Gude, E
Skulstad, H
Chetrit, M
Garcia-Izquierdo Jaen, E
Ha, J.W
Klein, A.L
Kikuchi, S
Ohte, N
Nagueh, S.F
Smiseth, O.A - Abstract:
- Abstract: Background: When evaluating left ventricular filling pressure (LVFP) according to current guidelines, tricuspid regurgitation (TR) velocity is often not available. Purpose: In the present study we investigate if left atrial (LA) reservoir strain may be used instead of TR velocity for evaluation of LVFP. Methods: We performed a prospective, multicenter, multinational and multivendor study in an all comer population of 322 patients with suspected heart failure or other cardiovascular disease where LVFP was measured by right- or left heart catheterization, as pulmonary capillary wedge pressure or pre-A LV diastolic pressure, respectively. Echocardiography was performed within 1 day of catheterization. 101 patients classified as special populations in the 2016 ASE/EACVI recommendations (i.e. non-cardiac pulmonary hypertension, atrial fibrillation, hypertrophic and restrictive cardiomyopathies) were excluded. Of the remaining 221 patients, 118 patients had EF ≥50% and 103 patients had EF <50%. Regression analysis was performed for LA reservoir strain and TR velocity against LVFP. LA reservoir strain at a cut-off value of <18% was applied instead of TR velocity in the 2016 ASE/EACVI algorithm and compared with the current algorithm. Results: LA reservoir strain correlated better with LVFP than TR velocity, r=0.62 vs 0.40 (p<0.01) (Figure 1). When replacing TR velocity with LA reservoir strain, the feasibility of the ASE/EACVI 2016 algorithm increased from 91.8% to 98.1%.Abstract: Background: When evaluating left ventricular filling pressure (LVFP) according to current guidelines, tricuspid regurgitation (TR) velocity is often not available. Purpose: In the present study we investigate if left atrial (LA) reservoir strain may be used instead of TR velocity for evaluation of LVFP. Methods: We performed a prospective, multicenter, multinational and multivendor study in an all comer population of 322 patients with suspected heart failure or other cardiovascular disease where LVFP was measured by right- or left heart catheterization, as pulmonary capillary wedge pressure or pre-A LV diastolic pressure, respectively. Echocardiography was performed within 1 day of catheterization. 101 patients classified as special populations in the 2016 ASE/EACVI recommendations (i.e. non-cardiac pulmonary hypertension, atrial fibrillation, hypertrophic and restrictive cardiomyopathies) were excluded. Of the remaining 221 patients, 118 patients had EF ≥50% and 103 patients had EF <50%. Regression analysis was performed for LA reservoir strain and TR velocity against LVFP. LA reservoir strain at a cut-off value of <18% was applied instead of TR velocity in the 2016 ASE/EACVI algorithm and compared with the current algorithm. Results: LA reservoir strain correlated better with LVFP than TR velocity, r=0.62 vs 0.40 (p<0.01) (Figure 1). When replacing TR velocity with LA reservoir strain, the feasibility of the ASE/EACVI 2016 algorithm increased from 91.8% to 98.1%. The accuracy of the algorithm was not significantly altered (80% vs 79%). An accuracy of 80% for the algorithm is lower than what has been reported in earlier publications, this may be due to inclusion of patients without suspected heart failure and no assessment of clinical data, which in turn may have influenced the accuracy of the algorithm. Conclusion: LA reservoir strain has better correlation to LVFP than TR velocity, and can be used in the ASE/EACVI 2016 algorithm for estimation of LVFP as a replacement when TR velocity is missing. Funding Acknowledgement: Type of funding source: Public Institution(s). Main funding source(s): South-Eastern Norway Regional Health Authority … (more)
- Is Part Of:
- European heart journal. Volume 41:(2020)Supplement 2
- Journal:
- European heart journal
- Issue:
- Volume 41:(2020)Supplement 2
- Issue Display:
- Volume 41, Issue 2 (2020)
- Year:
- 2020
- Volume:
- 41
- Issue:
- 2
- Issue Sort Value:
- 2020-0041-0002-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-11-25
- Subjects:
- Echocardiography: Systolic and Diastolic Function
Cardiology -- Periodicals
Heart -- Diseases -- Periodicals
616.12005 - Journal URLs:
- http://eurheartj.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/ehjci/ehaa946.0049 ↗
- Languages:
- English
- ISSNs:
- 0195-668X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.717500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 26678.xml