Thrombus formation on bioprosthetic aortic valves. (25th November 2020)
- Record Type:
- Journal Article
- Title:
- Thrombus formation on bioprosthetic aortic valves. (25th November 2020)
- Main Title:
- Thrombus formation on bioprosthetic aortic valves
- Authors:
- Bing, R
Andrews, J
Williams, M
Clark, T
Semple, S
Van Beek, E
Lucatelli, C
Sellers, S
Leipsic, J
Tavares, A
Stephens, A
Koglin, N
Dweck, M
Newby, D - Abstract:
- Abstract: Background: 18F-GP1 is a novel radiotracer with a high affinity for the platelet glycoprotein IIb/IIIa receptor. Subclinical bioprosthetic valve thrombus has been postulated as a trigger for accelerated valve degeneration. Purpose: To determine the feasibility of 18F-GP1 positron-emission tomography-computed tomography (PET-CT) for the detection of subclinical bioprosthetic aortic valve thrombus. Methods: (i) Explanted degenerated aortic valve prostheses underwent histology and imaging. (ii) In a prospective observational study, patients with bioprosthetic aortic valve replacement (AVR) underwent echocardiography and 18F-GP1 PET-CT. Valves were assessed for hypoattenuating leaflet thickening (HALT), hypo-attenuation affection leaflet motion (HAM) and GP1 uptake. Results: (i) GP1 correlated with thrombus on explanted valves (Figure). (ii) The first 6 patients (Table) were asymptomatic and had normally functioning surgical bioprostheses on echocardiography. At a median of 166 (range 122–189) days post-AVR, no patients had HALT or HAM on CT. There was avid focal GP1 uptake on the leaflets of all 6 patients which appeared most prominent along the leaflet edges (Figure). Only one patient had focal uptake in the valve frame, remote from the leaflets. In a separate cohort undergoing 18F-GP1 PET-CT for other conditions, there was no uptake on normal, native aortic valves (n=8). Conclusion: For the first time, we demonstrate that 18F-GP1 PET-CT is a highly sensitive methodAbstract: Background: 18F-GP1 is a novel radiotracer with a high affinity for the platelet glycoprotein IIb/IIIa receptor. Subclinical bioprosthetic valve thrombus has been postulated as a trigger for accelerated valve degeneration. Purpose: To determine the feasibility of 18F-GP1 positron-emission tomography-computed tomography (PET-CT) for the detection of subclinical bioprosthetic aortic valve thrombus. Methods: (i) Explanted degenerated aortic valve prostheses underwent histology and imaging. (ii) In a prospective observational study, patients with bioprosthetic aortic valve replacement (AVR) underwent echocardiography and 18F-GP1 PET-CT. Valves were assessed for hypoattenuating leaflet thickening (HALT), hypo-attenuation affection leaflet motion (HAM) and GP1 uptake. Results: (i) GP1 correlated with thrombus on explanted valves (Figure). (ii) The first 6 patients (Table) were asymptomatic and had normally functioning surgical bioprostheses on echocardiography. At a median of 166 (range 122–189) days post-AVR, no patients had HALT or HAM on CT. There was avid focal GP1 uptake on the leaflets of all 6 patients which appeared most prominent along the leaflet edges (Figure). Only one patient had focal uptake in the valve frame, remote from the leaflets. In a separate cohort undergoing 18F-GP1 PET-CT for other conditions, there was no uptake on normal, native aortic valves (n=8). Conclusion: For the first time, we demonstrate that 18F-GP1 PET-CT is a highly sensitive method of assessing platelet activation on bioprosthetic aortic valves. Despite the absence of CT evidence, early thrombus appeared to be a universal finding on recently implanted valve prostheses. The biological and clinical implications of subclinical bioprosthetic aortic valve thrombus have yet to be established. Funding Acknowledgement: Type of funding source: Foundation. Main funding source(s): British Heart Foundation … (more)
- Is Part Of:
- European heart journal. Volume 41:(2020)Supplement 2
- Journal:
- European heart journal
- Issue:
- Volume 41:(2020)Supplement 2
- Issue Display:
- Volume 41, Issue 2 (2020)
- Year:
- 2020
- Volume:
- 41
- Issue:
- 2
- Issue Sort Value:
- 2020-0041-0002-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-11-25
- Subjects:
- Positron Emission Tomography (PET)
Cardiology -- Periodicals
Heart -- Diseases -- Periodicals
616.12005 - Journal URLs:
- http://eurheartj.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/ehjci/ehaa946.0290 ↗
- Languages:
- English
- ISSNs:
- 0195-668X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.717500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 26678.xml