Differences in image density adjustment parameters on the image matching accuracy of a floor‐mounted kV X‐ray image‐guided radiation therapy system. Issue 2 (20th December 2021)
- Record Type:
- Journal Article
- Title:
- Differences in image density adjustment parameters on the image matching accuracy of a floor‐mounted kV X‐ray image‐guided radiation therapy system. Issue 2 (20th December 2021)
- Main Title:
- Differences in image density adjustment parameters on the image matching accuracy of a floor‐mounted kV X‐ray image‐guided radiation therapy system
- Authors:
- Sakuragawa, Kanako
Sasaki, Motoharu
Kamomae, Takeshi
Yokoishi, Michihiro
Kasai, Ryosuke
Kajino, Akimi
Ikushima, Hitoshi - Abstract:
- Abstract: This study aimed to investigate the effect of two different image density adjustment parameters on the results of image matching at six degrees of freedom using radiographic images generated by the ExacTrac X‐ray system in brain stereotactic radiosurgery (SRS). This study comprised 32 patients who underwent brain SRS at our hospital from January 2020 to December 2020. In this study, (1) the default parameter (an image density parameter between "tissue" and "bone") was an image density parameter for digitally reconstructed radiograph (DRR) generation used at many facilities, and (2) the bone parameter was the steepest contrast parameter used at our hospital. Of the 32 patients, 24 (75%) had a couch angle of 0.5 mm or more in the translational direction or 0.5° or more in the rotational direction, and 10 (31%) had a couch angle of 1.0 mm or more in the translational direction or 1.0° or more in the rotational direction. Among the 131 cases of all couch angles, 46 (35%) cases had a translational direction of 0.5 mm or more or a rotational direction of 0.5° or more, and 15 (11%) had a translational direction of 1.0 mm or more or a rotational direction of 1.0° or more. The results of this study indicate the usefulness of using appropriate DRR parameters for each case, rather than using the default settings. The use of appropriate DRR parameters can lead to accurate position matching results, leading to fewer image‐guided radiation therapy shots and a lower imaging dose.
- Is Part Of:
- Journal of applied clinical medical physics. Volume 23:Issue 2(2022)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 23:Issue 2(2022)
- Issue Display:
- Volume 23, Issue 2 (2022)
- Year:
- 2022
- Volume:
- 23
- Issue:
- 2
- Issue Sort Value:
- 2022-0023-0002-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2021-12-20
- Subjects:
- brain metastasis -- digitally reconstructed radiograph -- ExacTrac -- stereotactic radiosurgery
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/acm2.13505 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File: