18F-PSMA-1007 salivary gland dosimetry: comparison between different methods for dose calculation and assessment of inter- and intra-patient variability. (21st April 2023)
- Record Type:
- Journal Article
- Title:
- 18F-PSMA-1007 salivary gland dosimetry: comparison between different methods for dose calculation and assessment of inter- and intra-patient variability. (21st April 2023)
- Main Title:
- 18F-PSMA-1007 salivary gland dosimetry: comparison between different methods for dose calculation and assessment of inter- and intra-patient variability
- Authors:
- Pistone, Daniele
Gnesin, Silvano
Auditore, Lucrezia
Italiano, Antonio
Cascini, Giuseppe Lucio
Amato, Ernesto
Cicone, Francesco - Abstract:
- Abstract: Objective . Simplified calculation approaches and geometries are usually adopted for salivary glands (SGs) dosimetry. Our aims were (i) to compare different dosimetry methods to calculate SGs absorbed doses (ADs) following [ 18 F]-PSMA-1007 injection, and (ii) to assess the AD variation across patients and single SG components. Approach. Five patients with prostate cancer underwent sequential positron-emission tomography/computed tomography (PET/CT) acquisitions of the head and neck, 0.5, 2 and 4 h after [ 18 F]-PSMA-1007 injection. Parotid and submandibular glands were segmented on CT to derive SGs volumes and masses, while PET images were used to derive Time-Integrated Activity Coefficients. Average ADs to single SG components or total SG (tSG) were calculated with the following methods: (i) direct Monte Carlo simulation with GATE/GEANT4 considering radioactivity in the entire PET/CT field-of-view (MC) or in the SGs only (MCsgo); (ii) spherical model (SM) of OLINDA/EXM 2.1, adopting either patient-specific or standard ICRP89 organ masses (SMstd); (iii) ellipsoidal model (EM); (iv) MIRD approach with organ S -factors from OLINDA/EXM 2.1 and OpenDose collaboration, with or without contribution from cross irradiation originating outside the SGs. The maximum percent AD difference across SG components ( δ max ) and across patients (Δmax ) were calculated. Main results . Compared to MC, ADs to single SG components were significantly underestimated by all methodsAbstract: Objective . Simplified calculation approaches and geometries are usually adopted for salivary glands (SGs) dosimetry. Our aims were (i) to compare different dosimetry methods to calculate SGs absorbed doses (ADs) following [ 18 F]-PSMA-1007 injection, and (ii) to assess the AD variation across patients and single SG components. Approach. Five patients with prostate cancer underwent sequential positron-emission tomography/computed tomography (PET/CT) acquisitions of the head and neck, 0.5, 2 and 4 h after [ 18 F]-PSMA-1007 injection. Parotid and submandibular glands were segmented on CT to derive SGs volumes and masses, while PET images were used to derive Time-Integrated Activity Coefficients. Average ADs to single SG components or total SG (tSG) were calculated with the following methods: (i) direct Monte Carlo simulation with GATE/GEANT4 considering radioactivity in the entire PET/CT field-of-view (MC) or in the SGs only (MCsgo); (ii) spherical model (SM) of OLINDA/EXM 2.1, adopting either patient-specific or standard ICRP89 organ masses (SMstd); (iii) ellipsoidal model (EM); (iv) MIRD approach with organ S -factors from OLINDA/EXM 2.1 and OpenDose collaboration, with or without contribution from cross irradiation originating outside the SGs. The maximum percent AD difference across SG components ( δ max ) and across patients (Δmax ) were calculated. Main results . Compared to MC, ADs to single SG components were significantly underestimated by all methods (average relative differences ranging between −11.9% and −30.5%). δ max values were never below 25%. The highest δ max (=702%) was obtained with SMstd. Concerning tSG, results within 10% of the MC were obtained only if cross-irradiation from the remainder of the body or from the remainder of the head was accounted for. The Δmax ranged between 58% and 78% across patients. Significance . Simple geometrical models for SG dosimetry considerably underestimated ADs compared to MC, particularly if neglecting cross-irradiation from neighboring regions. Specific masses of single SG components should always be considered given their large intra- and inter-patient variability. … (more)
- Is Part Of:
- Physics in medicine & biology. Volume 68:Number 8(2023)
- Journal:
- Physics in medicine & biology
- Issue:
- Volume 68:Number 8(2023)
- Issue Display:
- Volume 68, Issue 8 (2023)
- Year:
- 2023
- Volume:
- 68
- Issue:
- 8
- Issue Sort Value:
- 2023-0068-0008-0000
- Page Start:
- Page End:
- Publication Date:
- 2023-04-21
- Subjects:
- PSMA -- salivary glands -- internal dosimetry -- parotids -- submandibular glands -- Monte Carlo -- GATE
Biophysics -- Periodicals
Medical physics -- Periodicals
610.153 - Journal URLs:
- http://ioppublishing.org/ ↗
http://iopscience.iop.org/0031-9155 ↗ - DOI:
- 10.1088/1361-6560/acc633 ↗
- Languages:
- English
- ISSNs:
- 0031-9155
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 26621.xml