Diffusion weighted hyperpolarized 129Xe MRI of the lung with 2D and 3D (FLORET) spiral. Issue 4 (9th November 2022)
- Record Type:
- Journal Article
- Title:
- Diffusion weighted hyperpolarized 129Xe MRI of the lung with 2D and 3D (FLORET) spiral. Issue 4 (9th November 2022)
- Main Title:
- Diffusion weighted hyperpolarized 129Xe MRI of the lung with 2D and 3D (FLORET) spiral
- Authors:
- Bdaiwi, Abdullah S.
Willmering, Matthew M.
Wang, Hui
Cleveland, Zackary I. - Abstract:
- Abstract : Purpose: To enable efficient hyperpolarized 129 Xe diffusion imaging using 2D and 3D (Fermat Looped, ORthogonally Encoded Trajectories, FLORET) spiral sequences and demonstrate that 129 Xe ADCs obtained using these sequences are comparable to those obtained using a conventional, 2D gradient‐recalled echo (GRE) sequence. Theory and Methods: Diffusion‐weighted 129 Xe MRI ( b ‐values = 0, 7.5, 15 s/cm 2 ) was performed in four healthy volunteers and one subject with lymphangioleiomyomatosis using slice‐selective 2D‐GRE (scan time = 15 s), slice‐selective 2D‐Spiral (4 s), and 3D‐FLORET (16 s) sequences. Experimental SNRs from b ‐value = 0 images ( SNR 0 EX $$ SNR{0}_{EX} $$ ) and mean ADC values were compared across sequences. In two healthy subjects, a second b = 0 image was acquired using the 2D‐Spiral sequence to map flip angle and correct RF‐induced, hyperpolarized signal decay at the voxel level, thus improving regional ADC estimates. Results: Diffusion‐weighted images from spiral sequences displayed image quality comparable to 2D‐GRE and produced sufficient SNR 0 EX $$ SNR{0}_{EX} $$ (16.8 ± 3.8 for 2D‐GRE, 21.2 ± 3.5 for 2D‐Spiral, 20.4 ± 3.5 for FLORET) to accurately calculate ADC. Whole‐lung means and SDs of ADC obtained via spiral were not significantly different ( P > 0.54) from those obtained via 2D‐GRE. Finally, 2D‐Spiral images were corrected for signal decay, which resulted in a whole‐lung mean ADC decrease of ˜15%, relative to uncorrected images.Abstract : Purpose: To enable efficient hyperpolarized 129 Xe diffusion imaging using 2D and 3D (Fermat Looped, ORthogonally Encoded Trajectories, FLORET) spiral sequences and demonstrate that 129 Xe ADCs obtained using these sequences are comparable to those obtained using a conventional, 2D gradient‐recalled echo (GRE) sequence. Theory and Methods: Diffusion‐weighted 129 Xe MRI ( b ‐values = 0, 7.5, 15 s/cm 2 ) was performed in four healthy volunteers and one subject with lymphangioleiomyomatosis using slice‐selective 2D‐GRE (scan time = 15 s), slice‐selective 2D‐Spiral (4 s), and 3D‐FLORET (16 s) sequences. Experimental SNRs from b ‐value = 0 images ( SNR 0 EX $$ SNR{0}_{EX} $$ ) and mean ADC values were compared across sequences. In two healthy subjects, a second b = 0 image was acquired using the 2D‐Spiral sequence to map flip angle and correct RF‐induced, hyperpolarized signal decay at the voxel level, thus improving regional ADC estimates. Results: Diffusion‐weighted images from spiral sequences displayed image quality comparable to 2D‐GRE and produced sufficient SNR 0 EX $$ SNR{0}_{EX} $$ (16.8 ± 3.8 for 2D‐GRE, 21.2 ± 3.5 for 2D‐Spiral, 20.4 ± 3.5 for FLORET) to accurately calculate ADC. Whole‐lung means and SDs of ADC obtained via spiral were not significantly different ( P > 0.54) from those obtained via 2D‐GRE. Finally, 2D‐Spiral images were corrected for signal decay, which resulted in a whole‐lung mean ADC decrease of ˜15%, relative to uncorrected images. Conclusions: Relative to GRE, efficient spiral sequences allow 129 Xe diffusion images to be acquired with isotropic lung coverage (3D), higher SNR $$ SNR $$ (2D and 3D), and three‐fold faster (2D) within a single breath‐hold. In turn, shortened breath‐holds enable flip‐angle mapping, and thus, allow RF‐induced signal decay to be corrected, increasing ADC accuracy. … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 89:Issue 4(2023)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 89:Issue 4(2023)
- Issue Display:
- Volume 89, Issue 4 (2023)
- Year:
- 2023
- Volume:
- 89
- Issue:
- 4
- Issue Sort Value:
- 2023-0089-0004-0000
- Page Start:
- 1342
- Page End:
- 1356
- Publication Date:
- 2022-11-09
- Subjects:
- ADC -- diffusion -- FLORET -- GRE -- hyperpolarized 129Xe -- spiral
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.29518 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 26630.xml