Hemodynamic Study of Stanford Type B Aortic Dissection Based on Ex Vivo Porcine Aorta Models. (June 2023)
- Record Type:
- Journal Article
- Title:
- Hemodynamic Study of Stanford Type B Aortic Dissection Based on Ex Vivo Porcine Aorta Models. (June 2023)
- Main Title:
- Hemodynamic Study of Stanford Type B Aortic Dissection Based on Ex Vivo Porcine Aorta Models
- Authors:
- Liang, Shichao
Jia, Heyue
Dong, Huiwu
Li, Zhenfeng
Zhou, Guojing
Zhang, Xuehuan
Chen, Duanduan
Xiong, Jiang - Abstract:
- Background: In this study, we aimed to evaluate hemodynamic influence of the dissected aortic system via various ex vivo type B aortic dissection (AD) models. Methods: Twenty-four raw porcine aortas were harvested and randomly divided into 4 groups to create various aortic models. Model A was the control group, while models B to D indicated the AD group, where models B and C presented a proximal primary entry with the false lumen (FL) lengths of 15 and 20 cm, respectively, and model D presented a 20 cm FL with a proximal primary entry and a distal reentry. All the aortic models were connected to a mock circulation loop to attain the realistic flow and pressure status. The flow distribution rate (FDR) of the aortic branches was calculated. Doppler ultrasound was applied to visualize the AD structure and to attain the velocity of flow in both the true and false lumens. Several sections of the AD were stained with hematoxylin and eosin for histologic evaluation after the experiment. Results: This study demonstrated that higher pressures were found for the AD group compared with the control group. The mean systolic pressures at the inlet of models A to D were 113.34±0.81, 120.58±0.52, 117.76±0.82, and 115.87±0.42 mm Hg, respectively. The FDRs of the celiac artery in models A to D were 8.65%, 8.32%±0.15%, 7.87%±0.13%, and 8.03%±0.21%, respectively. By ultrasound visualization, the velocity of the flow at the entry to the FL in the AD group ranged in 10 to 92 cm/s. The dissectionBackground: In this study, we aimed to evaluate hemodynamic influence of the dissected aortic system via various ex vivo type B aortic dissection (AD) models. Methods: Twenty-four raw porcine aortas were harvested and randomly divided into 4 groups to create various aortic models. Model A was the control group, while models B to D indicated the AD group, where models B and C presented a proximal primary entry with the false lumen (FL) lengths of 15 and 20 cm, respectively, and model D presented a 20 cm FL with a proximal primary entry and a distal reentry. All the aortic models were connected to a mock circulation loop to attain the realistic flow and pressure status. The flow distribution rate (FDR) of the aortic branches was calculated. Doppler ultrasound was applied to visualize the AD structure and to attain the velocity of flow in both the true and false lumens. Several sections of the AD were stained with hematoxylin and eosin for histologic evaluation after the experiment. Results: This study demonstrated that higher pressures were found for the AD group compared with the control group. The mean systolic pressures at the inlet of models A to D were 113.34±0.81, 120.58±0.52, 117.76±0.82, and 115.87±0.42 mm Hg, respectively. The FDRs of the celiac artery in models A to D were 8.65%, 8.32%±0.15%, 7.87%±0.13%, and 8.03%±0.21%, respectively. By ultrasound visualization, the velocity of the flow at the entry to the FL in the AD group ranged in 10 to 92 cm/s. The dissection flap presented pulsatile movement, especially in the models B and C which contained 1 primary entry without distal reentries. Histological examinations indicated that AD was located between the intimal and medial layers. Conclusions: Our ex vivo models demonstrated that the configuration of the dissected aorta influenced the pressure distribution. Moreover, the dissection flap affected the FDR of the aortic branches that possibly inducing malperfusion syndrome. … (more)
- Is Part Of:
- Journal of endovascular therapy. Volume 30:Number 3(2023)
- Journal:
- Journal of endovascular therapy
- Issue:
- Volume 30:Number 3(2023)
- Issue Display:
- Volume 30, Issue 3 (2023)
- Year:
- 2023
- Volume:
- 30
- Issue:
- 3
- Issue Sort Value:
- 2023-0030-0003-0000
- Page Start:
- 441
- Page End:
- 448
- Publication Date:
- 2023-06
- Subjects:
- aorta -- aortic dissection -- ex vivo model -- mock circulation loop -- hemodynamic analysis
Blood-vessels -- Endoscopic surgery -- Periodicals
Angioscopy -- Periodicals
Intravenous catheterization -- Periodicals
Peripheral vascular diseases -- Treatment -- Periodicals
Vascular Surgical Procedures -- Periodicals
Angioscopy -- Periodicals
Catheterization, Peripheral -- Periodicals
Peripheral Vascular Diseases -- therapy -- Periodicals
Angioscopie
Maladies vasculaires périphériques
617.413 - Journal URLs:
- http://jet.sagepub.com/ ↗
http://www.jevt.org ↗
http://www.uk.sagepub.com ↗ - DOI:
- 10.1177/15266028221081089 ↗
- Languages:
- English
- ISSNs:
- 1526-6028
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 26610.xml