Diagnosing Pathologic Complete Response in the Breast After Neoadjuvant Systemic Treatment of Breast Cancer Patients by Minimal Invasive Biopsy: Oral Presentation at the San Antonio Breast Cancer Symposium on Friday, December 13, 2019, Program Number GS5-03. Issue 3 (March 2022)
- Record Type:
- Journal Article
- Title:
- Diagnosing Pathologic Complete Response in the Breast After Neoadjuvant Systemic Treatment of Breast Cancer Patients by Minimal Invasive Biopsy: Oral Presentation at the San Antonio Breast Cancer Symposium on Friday, December 13, 2019, Program Number GS5-03. Issue 3 (March 2022)
- Main Title:
- Diagnosing Pathologic Complete Response in the Breast After Neoadjuvant Systemic Treatment of Breast Cancer Patients by Minimal Invasive Biopsy
- Authors:
- Heil, Joerg
Pfob, André
Sinn, Hans-Peter
Rauch, Geraldine
Bach, Paul
Thomas, Bettina
Schaefgen, Benedikt
Kuemmel, Sherko
Reimer, Toralf
Hahn, Markus
Thill, Marc
Blohmer, Jens-Uwe
Hackmann, John
Malter, Wolfram
Bekes, Inga
Friedrichs, Kay
Wojcinski, Sebastian
Joos, Sylvie
Paepke, Stefan
Ditsch, Nina
Rody, Achim
Große, Regina
van Mackelenbergh, Marion
Reinisch, Mattea
Karsten, Maria
Golatta, Michael - Abstract:
- Abstract : Objective: We evaluated the ability of minimally invasive, image-guided vacuum-assisted biopsy (VAB) to reliably diagnose a pathologic complete response in the breast (pCR-B). Summary Background Data: Neoadjuvant systemic treatment (NST) elicits a pathologic complete response in up to 80% of women with breast cancer. In such cases, breast surgery, the gold standard for confirming pCR-B, may be considered overtreatment. Methods: This multicenter, prospective trial enrolled 452 women presenting with initial stage 1-3 breast cancer of all biological subtypes. Fifty-four women dropped out; 398 were included in the full analysis. All participants had an imaging-confirmed partial or complete response to NST and underwent study-specific image-guided VAB before guideline-adherent breast surgery. The primary endpoint was the false-negative rate (FNR) of VAB-confirmed pCR-B. Results: Image-guided VAB alone did not detect surgically confirmed residual tumor in 37 of 208 women [FNR, 17.8%; 95% confidence interval (CI), 12.8–23.7%]. Of these 37 women, 12 (32.4%) had residual DCIS only, 20 (54.1%) had minimal residual tumor (<5 mm), and 19 of 25 (76.0%) exhibited invasive cancer cellularity of ⩽10%. In 19 of the 37 cases (51.4%), the false-negative result was potentially avoidable. Exploratory analysis showed that performing VAB with the largest needle by volume (7-gauge) resulted in no false-negative results and that combining imaging and image-guided VAB into a singleAbstract : Objective: We evaluated the ability of minimally invasive, image-guided vacuum-assisted biopsy (VAB) to reliably diagnose a pathologic complete response in the breast (pCR-B). Summary Background Data: Neoadjuvant systemic treatment (NST) elicits a pathologic complete response in up to 80% of women with breast cancer. In such cases, breast surgery, the gold standard for confirming pCR-B, may be considered overtreatment. Methods: This multicenter, prospective trial enrolled 452 women presenting with initial stage 1-3 breast cancer of all biological subtypes. Fifty-four women dropped out; 398 were included in the full analysis. All participants had an imaging-confirmed partial or complete response to NST and underwent study-specific image-guided VAB before guideline-adherent breast surgery. The primary endpoint was the false-negative rate (FNR) of VAB-confirmed pCR-B. Results: Image-guided VAB alone did not detect surgically confirmed residual tumor in 37 of 208 women [FNR, 17.8%; 95% confidence interval (CI), 12.8–23.7%]. Of these 37 women, 12 (32.4%) had residual DCIS only, 20 (54.1%) had minimal residual tumor (<5 mm), and 19 of 25 (76.0%) exhibited invasive cancer cellularity of ⩽10%. In 19 of the 37 cases (51.4%), the false-negative result was potentially avoidable. Exploratory analysis showed that performing VAB with the largest needle by volume (7-gauge) resulted in no false-negative results and that combining imaging and image-guided VAB into a single diagnostic test lowered the FNR to 6.2% (95% CI, 3.4%–10.5%). Conclusions: Image-guided VAB missed residual disease more often than expected. Refinements in procedure and patient selection seem possible and necessary before omitting breast surgery. Abstract : Supplemental Digital Content is available in the text … (more)
- Is Part Of:
- Annals of surgery. Volume 275:Issue 3(2022)
- Journal:
- Annals of surgery
- Issue:
- Volume 275:Issue 3(2022)
- Issue Display:
- Volume 275, Issue 3 (2022)
- Year:
- 2022
- Volume:
- 275
- Issue:
- 3
- Issue Sort Value:
- 2022-0275-0003-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-03
- Subjects:
- breast cancer surgery -- complete response -- individualized treatment -- neoadjuvant systemic treatment -- surgical de-escalation -- vacuum-assisted biopsy
Surgery -- Periodicals
617.005 - Journal URLs:
- http://www.annalsofsurgery.com ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/SLA.0000000000004246 ↗
- Languages:
- English
- ISSNs:
- 0003-4932
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1044.500000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 26584.xml