Assessment of log‐based fingerprinting system of Mobius3D with Elekta linear accelerators. Issue 2 (27th November 2021)
- Record Type:
- Journal Article
- Title:
- Assessment of log‐based fingerprinting system of Mobius3D with Elekta linear accelerators. Issue 2 (27th November 2021)
- Main Title:
- Assessment of log‐based fingerprinting system of Mobius3D with Elekta linear accelerators
- Authors:
- Noh, Yu‐Yun
Kim, Jihun
Kim, Jin Sung
Shin, Han‐Back
Han, Min Cheol
Suh, Tae Suk - Abstract:
- Abstract: Purpose: The purpose of this study was to investigate the matching error that occurs when the Mobius3D fingerprinting system is applied in conjunction with an Elekta linear accelerator (LINAC) and to offer an acceptable and alternative method for circumventing this problem. Material and methods: To avoid the multileaf collimator (MLC) conflicting error in the Mobius3D fingerprinting system, we developed an in‐house program to move the MLC in the Digital Imaging and Communications in Medicine (DICOM) radiotherapy (RT)‐Plan to pertinent positions, considering the relationship between log data and planned data. The re‐delivered log files were calculated in the Mobius3D system, and the results were compared with those of corrected data (i.e., we analyzed a pair of re‐collected log data and the previous DICOM RT‐Plan data). The results were then evaluated by comparing several items, such as point dose errors, gamma index (GI) passing rates, and MLC root‐mean‐square (RMS) values. Results: For the point dose error, the maximum difference found was below 2.0%. In the case of GI analysis of all plans, the maximum difference in the passing rates was below 1.4%. The statistical results obtained using a paired Student's t ‐test showed that there were no significant differences within the uncertainty. In the case of the RMS test, the maximum difference found was approximately 0.08 mm. Conclusions: Our results showed that all the mismatched log files were sufficiently acceptableAbstract: Purpose: The purpose of this study was to investigate the matching error that occurs when the Mobius3D fingerprinting system is applied in conjunction with an Elekta linear accelerator (LINAC) and to offer an acceptable and alternative method for circumventing this problem. Material and methods: To avoid the multileaf collimator (MLC) conflicting error in the Mobius3D fingerprinting system, we developed an in‐house program to move the MLC in the Digital Imaging and Communications in Medicine (DICOM) radiotherapy (RT)‐Plan to pertinent positions, considering the relationship between log data and planned data. The re‐delivered log files were calculated in the Mobius3D system, and the results were compared with those of corrected data (i.e., we analyzed a pair of re‐collected log data and the previous DICOM RT‐Plan data). The results were then evaluated by comparing several items, such as point dose errors, gamma index (GI) passing rates, and MLC root‐mean‐square (RMS) values. Results: For the point dose error, the maximum difference found was below 2.0%. In the case of GI analysis of all plans, the maximum difference in the passing rates was below 1.4%. The statistical results obtained using a paired Student's t ‐test showed that there were no significant differences within the uncertainty. In the case of the RMS test, the maximum difference found was approximately 0.08 mm. Conclusions: Our results showed that all the mismatched log files were sufficiently acceptable within the uncertainty. We conclude that the matching error obtained when applying Mobius3D to an Elekta LINAC may be addressed using a simple modification of the fingerprinting system, and we expect that our study findings will help vendors resolve this issue in the near future. … (more)
- Is Part Of:
- Journal of applied clinical medical physics. Volume 23:Issue 2(2022)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 23:Issue 2(2022)
- Issue Display:
- Volume 23, Issue 2 (2022)
- Year:
- 2022
- Volume:
- 23
- Issue:
- 2
- Issue Sort Value:
- 2022-0023-0002-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2021-11-27
- Subjects:
- Elekta LINAC -- matching error -- Mobius3D -- patient‐specific QA
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/acm2.13480 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 26587.xml