UHPLC-APCI-TQ-MS analytical method to quantify nitrosamine impurities in the commercial formulation of metformin and glipizide. Issue 5 (9th May 2022)
- Record Type:
- Journal Article
- Title:
- UHPLC-APCI-TQ-MS analytical method to quantify nitrosamine impurities in the commercial formulation of metformin and glipizide. Issue 5 (9th May 2022)
- Main Title:
- UHPLC-APCI-TQ-MS analytical method to quantify nitrosamine impurities in the commercial formulation of metformin and glipizide
- Authors:
- Solanki, Ravisinh
Patel, Chhaganbhai
Patel, Ravi
Maradiya, Anujkumar
Parikh, Shalin
Gayakvad, Bhavinkumar - Abstract:
- Abstract: As per the ICH M7 guideline nitrosamine impurities are referred to as cohort of concern which are having a potential significant carcinogenic risk and for the safe human consumption of drug products, the levels of nitrosamine impurities need to be controlled as per respective permissible daily exposures (PDE). An accurate, precise, sensitive, and robust UPLC-APCI-TQ-MS/MS method has been developed for the quantification of eight nitrosamine impurities in the marketed formulation of metformin and glipizide Tablets. Chromatographic separation was achieved using Kinetex ® 150 × 3.0 mm Biphenyl 100 Å, 2.6 µm column with mobile phase A (0.1% w/v formic acid dissolved in water) and mobile phase B (0.1% w/v formic acid dissolved in methanol) with a flow rate of 0.4 mL per minute having run time of 20 min with gradient mode of elution. As per ICH Q2(R1) guideline the method had been validated which demonstrates the sensitivity of the developed method with a good linearity range of 1–5 ng/mL for all eight nitrosamine impurities. The validation parameters suggest that the developed method for the simultaneous quantification of eight nitrosamine impurities in the marketed formulation of metformin hydrochloride and glipizide can be routinely applied in the quality control laboratory. Graphical Abstract: UF0001
- Is Part Of:
- Journal of liquid chromatography & related technologies. Volume 45:Issue 5/8(2023)
- Journal:
- Journal of liquid chromatography & related technologies
- Issue:
- Volume 45:Issue 5/8(2023)
- Issue Display:
- Volume 45, Issue 5 (2023)
- Year:
- 2023
- Volume:
- 45
- Issue:
- 5
- Issue Sort Value:
- 2023-0045-0005-0000
- Page Start:
- 84
- Page End:
- 93
- Publication Date:
- 2022-05-09
- Subjects:
- Carcinogenic -- nitrosamine impurities -- N-nitrosodimethylamine (NDMA) -- N-nitroso-N-methyl-4-aminobutyric acid (NMBA) -- validation
Liquid chromatography -- Periodicals
Chromatographic analysis -- Periodicals
Separation (Technology) -- Periodicals
Biotechnology -- Periodicals
Chromatography, Liquid -- Periodicals
543.8405 - Journal URLs:
- http://www.tandfonline.com/toc/ljlc20/current ↗
http://www.tandfonline.com/ ↗ - DOI:
- 10.1080/10826076.2022.2126856 ↗
- Languages:
- English
- ISSNs:
- 1082-6076
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5010.510500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 26561.xml