Corossion failure analysis on cotter pins used for fittings of 500kV transmission tower. Issue 1 (May 2021)
- Record Type:
- Journal Article
- Title:
- Corossion failure analysis on cotter pins used for fittings of 500kV transmission tower. Issue 1 (May 2021)
- Main Title:
- Corossion failure analysis on cotter pins used for fittings of 500kV transmission tower
- Authors:
- Hao, Chen
Xin, Du
Wei, Sun
Xin, Qiao
Xinai, Guo - Abstract:
- Abstract: Transmission line is an important part of power system and plays a key role in the process of power transmission and distribution. As the skeleton of the transmission line, the reliability of the transmission tower is an important guarantee for the safe and stable operation of the power grid. In this paper, the corroded cotter pins of fittings used for 500kV transmission tower was investigated by means of macro-morphology inspection, chemical composition analysis, scanning electron micrograph analysis, microstructure analysis and energy spectrum analysis. The result showed that the misuse of material for cotter pins and sulfide discharged from industrial production were the main causes of corrosion of the cotter pins.
- Is Part Of:
- Journal of physics. Volume 1939:Issue 1(2021)
- Journal:
- Journal of physics
- Issue:
- Volume 1939:Issue 1(2021)
- Issue Display:
- Volume 1939, Issue 1 (2021)
- Year:
- 2021
- Volume:
- 1939
- Issue:
- 1
- Issue Sort Value:
- 2021-1939-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-05
- Subjects:
- Physics -- Congresses
530.5 - Journal URLs:
- http://www.iop.org/EJ/journal/1742-6596 ↗
http://ioppublishing.org/ ↗ - DOI:
- 10.1088/1742-6596/1939/1/012028 ↗
- Languages:
- English
- ISSNs:
- 1742-6588
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5036.223000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 26474.xml