- Abstract: This work evaluates alternative four-point bending fatigue stress in 2 < pH < 4 corrosive media of AISI/SAE 1015 steel subjected to shot peening surface treatment. A tri factorial experimental design with replications was used. The intervening factors were: i) load levels, 0.96, 0.85, 0.73, 0.65; ii) corrosive media; pH2, pH4, ambient; iii) shot-peening surface treatment; without any shot peening, S230 shot peening and CW-41 shot peening, for which a total of 108 specimens were tested with a reliability level of 95% and a probability of failure of 3%. Tests were performed on a universal machine in a three-point bending assembly with an electro-pneumatic system. The cycle counting and control were performed by a programmable logic controller. The results of the stress-life method in each one of the scenarios show that the best condition was shown in the probes with shot peening S230 and CW-41 treatment under atmospheric conditions, where the material tends to increase its fatigue behavior; the number of cycles reached 36990 and 37773 respectively. The corrosive effect of pH2 and pH4 reduced on probes without shot peening treatment with a maximum of 9862 and 8670 cycles respectively; however, for S230 and CW-41 shots, an increase in cycle number in pH2 and pH4 was evidenced, with the best result for S230 shot at pH4 with a maximum range of 21568. Likewise, the fractography analysis shows mixed fractures with fatigue failure mechanism; the characteristics found wereAbstract: This work evaluates alternative four-point bending fatigue stress in 2 < pH < 4 corrosive media of AISI/SAE 1015 steel subjected to shot peening surface treatment. A tri factorial experimental design with replications was used. The intervening factors were: i) load levels, 0.96, 0.85, 0.73, 0.65; ii) corrosive media; pH2, pH4, ambient; iii) shot-peening surface treatment; without any shot peening, S230 shot peening and CW-41 shot peening, for which a total of 108 specimens were tested with a reliability level of 95% and a probability of failure of 3%. Tests were performed on a universal machine in a three-point bending assembly with an electro-pneumatic system. The cycle counting and control were performed by a programmable logic controller. The results of the stress-life method in each one of the scenarios show that the best condition was shown in the probes with shot peening S230 and CW-41 treatment under atmospheric conditions, where the material tends to increase its fatigue behavior; the number of cycles reached 36990 and 37773 respectively. The corrosive effect of pH2 and pH4 reduced on probes without shot peening treatment with a maximum of 9862 and 8670 cycles respectively; however, for S230 and CW-41 shots, an increase in cycle number in pH2 and pH4 was evidenced, with the best result for S230 shot at pH4 with a maximum range of 21568. Likewise, the fractography analysis shows mixed fractures with fatigue failure mechanism; the characteristics found were beach marks, secondary cracks, localized oxidation (filiform, plates, pitting, stress, and compression corrosion), nucleation, microvoids, cleavage facets, intergranular and transgranular cracks. … (more)
- Is Part Of:
- Journal of physics. Volume 1938:Issue 1(2021)
- Journal:
- Journal of physics
- Issue:
- Volume 1938:Issue 1(2021)
- Issue Display:
- Volume 1938, Issue 1 (2021)
- Year:
- 2021
- Volume:
- 1938
- Issue:
- 1
- Issue Sort Value:
- 2021-1938-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-05
- Subjects:
- Physics -- Congresses
530.5 - Journal URLs:
- http://www.iop.org/EJ/journal/1742-6596 ↗
http://ioppublishing.org/ ↗ - DOI:
- 10.1088/1742-6596/1938/1/012005 ↗
- Languages:
- English
- ISSNs:
- 1742-6588
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5036.223000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 26477.xml