PS-BPC03-7: ARE OSCILLOMETRIC WAVEFORMS DIFFERENT IN PREGNANCY?. (January 2023)
- Record Type:
- Journal Article
- Title:
- PS-BPC03-7: ARE OSCILLOMETRIC WAVEFORMS DIFFERENT IN PREGNANCY?. (January 2023)
- Main Title:
- PS-BPC03-7: ARE OSCILLOMETRIC WAVEFORMS DIFFERENT IN PREGNANCY?
- Authors:
- Ringrose, Jennifer
Araneta, Patricia
Chan, Lillian
Kassam, Jalisa
Wirzba, Mira
Greef, Kate
Ramsay, Gillian
Sia, Winnie
Khurana, Rshmi
Bader, Erin
Sridar, Sangita
Padwal, Raj - Abstract:
- Abstract : Objective: Hypertensive disorders of pregnancy are leading causes of maternal and perinatal morbidity and mortality. Automated blood pressure (BP) measurements are being used in clinical practice; however, understanding of how oscillometric waveform vary between pregnant and non-pregnant individuals remains low. Design and Methods: Pregnant individuals over 20 weeks gestational age and healthy, non-pregnant women were recruited. Healthy, non-pregnant women (HNP) were matched to healthy pregnant women (HP), and pregnant women with a hypertensive disorder of pregnancy (HDP) by age (± 10 years), arm circumference (± 6 cm), and BMI at the time of BP measurement (± 13 kg/m2). There were seven individuals in each group for a total of 21 participants. BP measurements were done per the International Organization for Standardization (ISO) protocol using a custom-built oscillometric device as the test device and 2-observer mercury auscultation as the reference measurement. Four pairs of auscultatory measurements and four oscillometric measurements were obtained for each participant. Baseline demographics, auscultatory BP and BP derived from slope-based and fixed ratio algorithms were determined. Oscillometric waveform and envelope features were compared among groups. Results: In HNP, HP, and HDP groups respectively: mean age was 31.3 ± 4.8; 32.1 ± 3.6; 32.0 ± 4.4 years; arm circumference 31.9 ± 3.3; 32.3 ± 4.9; 34.0 ± 3.3 cm; BMI 26.8 ± 3.8; 32.0 ± 7.2; 32.4 ± 3.7 kg/m2;Abstract : Objective: Hypertensive disorders of pregnancy are leading causes of maternal and perinatal morbidity and mortality. Automated blood pressure (BP) measurements are being used in clinical practice; however, understanding of how oscillometric waveform vary between pregnant and non-pregnant individuals remains low. Design and Methods: Pregnant individuals over 20 weeks gestational age and healthy, non-pregnant women were recruited. Healthy, non-pregnant women (HNP) were matched to healthy pregnant women (HP), and pregnant women with a hypertensive disorder of pregnancy (HDP) by age (± 10 years), arm circumference (± 6 cm), and BMI at the time of BP measurement (± 13 kg/m2). There were seven individuals in each group for a total of 21 participants. BP measurements were done per the International Organization for Standardization (ISO) protocol using a custom-built oscillometric device as the test device and 2-observer mercury auscultation as the reference measurement. Four pairs of auscultatory measurements and four oscillometric measurements were obtained for each participant. Baseline demographics, auscultatory BP and BP derived from slope-based and fixed ratio algorithms were determined. Oscillometric waveform and envelope features were compared among groups. Results: In HNP, HP, and HDP groups respectively: mean age was 31.3 ± 4.8; 32.1 ± 3.6; 32.0 ± 4.4 years; arm circumference 31.9 ± 3.3; 32.3 ± 4.9; 34.0 ± 3.3 cm; BMI 26.8 ± 3.8; 32.0 ± 7.2; 32.4 ± 3.7 kg/m2; mean auscultatory BP (systolic/diastolic) 103.3 ± 11.1/66.5 ± 7.4; 110.6 ± 4.0/56.9 ± 6.5; 132.6 ± 19.0/83.9 ± 13.3 mmHg. HDP had significantly higher auscultatory systolic (P < 0.05) and diastolic (p < 0.01) BP than the other groups. The pregnant groups (HP, HDP) had significantly higher heart rate (p < 0.01); higher pulses (p < 0.05) in the oscillometric waveform (OMV); lower average width in the pulses (p < 0.01); higher pressure amplitude at which the OMW peaks (p < 0.05) with longer time to reach this maximum pressure amplitude (p < 0.05); greater area under the curve (p < 0.01). Compared to HNP, the HDP showed significantly skewed OMW to the right (p < 0.01); greater spread in the OMW envelope (p < 0.05) and lesser random variation in the OMW envelope (p < 0.01). A typical OMV with the 3 groups superimposed is demonstrated in Figure 1. Conclusion: Significant differences in the oscillometric waveform morphology and parameters were found in pregnancy and in hypertensive disorders of pregnancy compared to healthy controls. These results suggest that pregnancy-specific algorithms may be required to optimize accuracy for oscillometric BP measurement. … (more)
- Is Part Of:
- Journal of hypertension. Volume 41(2023)Supplement 1
- Journal:
- Journal of hypertension
- Issue:
- Volume 41(2023)Supplement 1
- Issue Display:
- Volume 41, Issue 1 (2023)
- Year:
- 2023
- Volume:
- 41
- Issue:
- 1
- Issue Sort Value:
- 2023-0041-0001-0000
- Page Start:
- e298
- Page End:
- Publication Date:
- 2023-01
- Subjects:
- Hypertension -- Periodicals
Hypertension -- Periodicals
616.132005 - Journal URLs:
- http://firstsearch.oclc.org ↗
http://journals.lww.com/jhypertension/pages/default.aspx ↗
http://ovidsp.ovid.com/ovidweb.cgi?T=JS&NEWS=n&CSC=Y&PAGE=toc&D=yrovft&AN=00004872-000000000-00000 ↗
http://www.jhypertension.com/ ↗
http://journals.lww.com/pages/default.aspx ↗ - DOI:
- 10.1097/01.hjh.0000915776.18974.97 ↗
- Languages:
- English
- ISSNs:
- 1473-5598
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5004.510000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 26437.xml