PS-C08-3: TOO-LARGE AND TOO-SMALL CUFF SIZES RESULTS RESULTS IN SUBSTANTIAL BLOOD PRESSURE MEASUREMENT ERROR: RESULTS FROM THE CUFF(SZ) RANDOMIZED TRIAL. (January 2023)
- Record Type:
- Journal Article
- Title:
- PS-C08-3: TOO-LARGE AND TOO-SMALL CUFF SIZES RESULTS RESULTS IN SUBSTANTIAL BLOOD PRESSURE MEASUREMENT ERROR: RESULTS FROM THE CUFF(SZ) RANDOMIZED TRIAL. (January 2023)
- Main Title:
- PS-C08-3: TOO-LARGE AND TOO-SMALL CUFF SIZES RESULTS RESULTS IN SUBSTANTIAL BLOOD PRESSURE MEASUREMENT ERROR: RESULTS FROM THE CUFF(SZ) RANDOMIZED TRIAL
- Authors:
- Brady, Tammy Mcloughlin
Charleston, Jeanne
Ishigami, Junichi
Prokopowicz, Greg
Miller, Edgar
Matsushita, Kunihiro
Appel, Lawrence - Abstract:
- Abstract : Objective: Proper cuff-size based on measured mid-arm circumference is recommended for accurate blood pressure (BP) determination. The impact of mis-cuffing (using a too-small or too-large cuff) on BP when using an automated BP device has not been rigorously tested. We aimed to determine the effects of mis-cuffing on automated BP. Design and Methods: We conducted a randomized cross-over trial of 195 community-dwelling adults [mean age 54 yrs, 34% male (n = 67), 68% Black (n = 132)]. Participants had 3 sets of triplicate BP measurements (WelchAllyn ProB 2000) using an appropriately sized cuff and two additional cuff sizes (too-small and/or too-large), in random order. Results: 31% (n = 60) of the study participants had systolic BP (SBP) > = 130 mmHg, and 36% (n = 71) had a body mass index > = 30 kg/m2. As shown in the Figure, among persons in whom a small adult cuff was appropriately sized, too-large cuffs resulted in significantly lower SBP readings [regular adult cuff: -3.6 (-1.7 to -5.6) and large adult cuff: -7.5 (-5.5 to -9.6)]. In contrast, among persons in whom an extra-large adult cuff was appropriately sized, too-small cuffs resulted in significantly higher SBP readings [large adult cuff: + 9.6 (+7.3 to + 11.9) and regular adult cuff: + 19.5 (+16.1 to + 22.9)]. Similar effects were seen for mis-cuffing when an appropriate cuff was either a regular adult cuff or large adult cuff. We also observed similar patterns for diastolic BP. Conclusions: AppropriateAbstract : Objective: Proper cuff-size based on measured mid-arm circumference is recommended for accurate blood pressure (BP) determination. The impact of mis-cuffing (using a too-small or too-large cuff) on BP when using an automated BP device has not been rigorously tested. We aimed to determine the effects of mis-cuffing on automated BP. Design and Methods: We conducted a randomized cross-over trial of 195 community-dwelling adults [mean age 54 yrs, 34% male (n = 67), 68% Black (n = 132)]. Participants had 3 sets of triplicate BP measurements (WelchAllyn ProB 2000) using an appropriately sized cuff and two additional cuff sizes (too-small and/or too-large), in random order. Results: 31% (n = 60) of the study participants had systolic BP (SBP) > = 130 mmHg, and 36% (n = 71) had a body mass index > = 30 kg/m2. As shown in the Figure, among persons in whom a small adult cuff was appropriately sized, too-large cuffs resulted in significantly lower SBP readings [regular adult cuff: -3.6 (-1.7 to -5.6) and large adult cuff: -7.5 (-5.5 to -9.6)]. In contrast, among persons in whom an extra-large adult cuff was appropriately sized, too-small cuffs resulted in significantly higher SBP readings [large adult cuff: + 9.6 (+7.3 to + 11.9) and regular adult cuff: + 19.5 (+16.1 to + 22.9)]. Similar effects were seen for mis-cuffing when an appropriate cuff was either a regular adult cuff or large adult cuff. We also observed similar patterns for diastolic BP. Conclusions: Appropriate cuff selection is essential for accurate BP measurement. Choosing a too-large or too-small cuff can result in clinically meaningful errors in BP reading which could lead to under- or over-treatment of hypertension. … (more)
- Is Part Of:
- Journal of hypertension. Volume 41(2023)Supplement 1
- Journal:
- Journal of hypertension
- Issue:
- Volume 41(2023)Supplement 1
- Issue Display:
- Volume 41, Issue 1 (2023)
- Year:
- 2023
- Volume:
- 41
- Issue:
- 1
- Issue Sort Value:
- 2023-0041-0001-0000
- Page Start:
- e203
- Page End:
- e204
- Publication Date:
- 2023-01
- Subjects:
- Hypertension -- Periodicals
Hypertension -- Periodicals
616.132005 - Journal URLs:
- http://firstsearch.oclc.org ↗
http://journals.lww.com/jhypertension/pages/default.aspx ↗
http://ovidsp.ovid.com/ovidweb.cgi?T=JS&NEWS=n&CSC=Y&PAGE=toc&D=yrovft&AN=00004872-000000000-00000 ↗
http://www.jhypertension.com/ ↗
http://journals.lww.com/pages/default.aspx ↗ - DOI:
- 10.1097/01.hjh.0000914760.89745.36 ↗
- Languages:
- English
- ISSNs:
- 1473-5598
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5004.510000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 26436.xml