Early clinical and haemodynamic matched comparison of balloon-expandable valves. Issue 9 (20th July 2021)
- Record Type:
- Journal Article
- Title:
- Early clinical and haemodynamic matched comparison of balloon-expandable valves. Issue 9 (20th July 2021)
- Main Title:
- Early clinical and haemodynamic matched comparison of balloon-expandable valves
- Authors:
- Delgado-Arana, Jose R
Gordillo-Monge, María X
Halim, Jonathan
De Marco, Federico
Trani, Carlo
Martin, Pedro
Infusino, Fabio
Ancona, Marco
den Heijer, Peter
Bedogni, Francesco
Nombela Franco, Luis
Moreno, Raul
Sargella, Gennaro
Montorfano, Matteo
Aristizabal-Duque, Cristhian
Romero-Delgado, Teresa
Santos, Sandra
Barrero, Alejandro
Gomez Salvador, Itziar
IJsselmuiden, Sander
Redondo Diéguez, Alfredo
San Román Calvar, José Alberto
Amat-Santos, Ignacio J - Abstract:
- Abstract : Objectives: The balloon-expandable Sapien-3 valve demonstrated superior results in terms of residual aortic regurgitation when compared with self-expandable devices. We aimed to compare for the first-time early outcomes of Sapien-3 transcatheter heart valve (THV) with the balloon-expandable Myval device. Methods: Consecutive real-world patients from nine European institutions with symptomatic severe aortic stenosis treated either with Sapien-3 or Myval THV devices after June 2018 were compared. Early clinical outcomes were prospectively gathered and blinded analysis of 30-day echocardiography was conducted. Matching for the following variables was performed: age, body surface area, Society of Thoracic Surgeons risk score, left ventricular function, mean gradient, transfemoral approach, aortic valvular calcium, aortic annulus mean diameter, area and eccentricity index. Results: A total of 416 patients treated either with the Sapien-3 (n=286, 68.7%) or with Myval THV (n=130, 31.3%) were included and 103 pairs compared after matching. Baseline characteristics were similar. Procedural success rate (Sapien-3: 94.2%; Myval: 93.2%, p=0.219), 30-day mortality (Sapien-3: 2.9%; Myval: 0.97%, p=0.625), clinical efficacy (12.6 vs 4.9%, p=0.057) and early safety (12.6 vs 4.9%, p=0.096) were comparable. There was a lower need for new permanent pacemaker (15.5 vs 5.8% p=0.020) with Myval. No significant differences were found in terms of ≥moderate aortic regurgitation (1% forAbstract : Objectives: The balloon-expandable Sapien-3 valve demonstrated superior results in terms of residual aortic regurgitation when compared with self-expandable devices. We aimed to compare for the first-time early outcomes of Sapien-3 transcatheter heart valve (THV) with the balloon-expandable Myval device. Methods: Consecutive real-world patients from nine European institutions with symptomatic severe aortic stenosis treated either with Sapien-3 or Myval THV devices after June 2018 were compared. Early clinical outcomes were prospectively gathered and blinded analysis of 30-day echocardiography was conducted. Matching for the following variables was performed: age, body surface area, Society of Thoracic Surgeons risk score, left ventricular function, mean gradient, transfemoral approach, aortic valvular calcium, aortic annulus mean diameter, area and eccentricity index. Results: A total of 416 patients treated either with the Sapien-3 (n=286, 68.7%) or with Myval THV (n=130, 31.3%) were included and 103 pairs compared after matching. Baseline characteristics were similar. Procedural success rate (Sapien-3: 94.2%; Myval: 93.2%, p=0.219), 30-day mortality (Sapien-3: 2.9%; Myval: 0.97%, p=0.625), clinical efficacy (12.6 vs 4.9%, p=0.057) and early safety (12.6 vs 4.9%, p=0.096) were comparable. There was a lower need for new permanent pacemaker (15.5 vs 5.8% p=0.020) with Myval. No significant differences were found in terms of ≥moderate aortic regurgitation (1% for Sapien-3, 0% for Myval, p=0.314), but mean gradients were higher following Sapien-3 than after Myval (p<0.001). Conclusions: The new Myval balloon-expandable THV was favourable in terms of safety, with low rate of permanent pacemaker and with favourable residual gradients and paravalvular leak rate according to blinded echocardiographic analysis. … (more)
- Is Part Of:
- Heart. Volume 108:Issue 9(2022)
- Journal:
- Heart
- Issue:
- Volume 108:Issue 9(2022)
- Issue Display:
- Volume 108, Issue 9 (2022)
- Year:
- 2022
- Volume:
- 108
- Issue:
- 9
- Issue Sort Value:
- 2022-0108-0009-0000
- Page Start:
- 725
- Page End:
- 732
- Publication Date:
- 2021-07-20
- Subjects:
- transcatheter aortic valve replacement -- aortic valve stenosis
Heart -- Diseases -- Treatment -- Periodicals
Cardiology -- Periodicals
616.12 - Journal URLs:
- http://www.bmj.com/archive ↗
http://heart.bmj.com ↗
http://www.heartjnl.com ↗ - DOI:
- 10.1136/heartjnl-2021-319349 ↗
- Languages:
- English
- ISSNs:
- 1355-6037
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 26393.xml