Performance study of air-type BIPVT coupled water-cooled wall. (December 2022)
- Record Type:
- Journal Article
- Title:
- Performance study of air-type BIPVT coupled water-cooled wall. (December 2022)
- Main Title:
- Performance study of air-type BIPVT coupled water-cooled wall
- Authors:
- Zhao, Yulong
Diao, Hongmei
Zhang, Guoyin
Ge, Minghui - Abstract:
- Abstract: Building-integrated photovoltaic-thermal (BIPVT) systems can provide both electrical and thermal energy for building, realizing efficient use of solar power and decreasing the energy consumption of the building. In this study, water-cooled walls were installed on both sides of the air flow channel to improve the heat exchange between the photovoltaic (PV) panels and the air by cooling the air, thus realizing an improvement in the thermal/electrical performance of air-type BIPVT. An experimental system of coupled BIPVTs was conducted to study the influence of cooling water temperature on performance of the system. The results show that a 10 K reduction in cooling water temperature increases the heat efficiency by 26% and the electrical efficiency by approximately 2%. The results can be used for the optimized operation of BIPVT system.
- Is Part Of:
- Energy reports. Volume 8(2022)Supplement 16
- Journal:
- Energy reports
- Issue:
- Volume 8(2022)Supplement 16
- Issue Display:
- Volume 8, Issue 16 (2022)
- Year:
- 2022
- Volume:
- 8
- Issue:
- 16
- Issue Sort Value:
- 2022-0008-0016-0000
- Page Start:
- 265
- Page End:
- 270
- Publication Date:
- 2022-12
- Subjects:
- Building-integrated photovoltaic-thermal -- Thermal efficiency -- Relative power generation -- Superheat
Power resources -- Periodicals
Energy industries -- Periodicals
Power resources
Periodicals
Electronic journals
621.04205 - Journal URLs:
- http://www.sciencedirect.com/science/journal/23524847/ ↗
http://www.sciencedirect.com/ ↗ - DOI:
- 10.1016/j.egyr.2022.10.278 ↗
- Languages:
- English
- ISSNs:
- 2352-4847
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File: