Comparing the usefulness of a new algorithm to measure visual field using the variational Bayes linear regression in glaucoma patients, in comparison to the Swedish interactive thresholding algorithm. Issue 5 (13th January 2021)
- Record Type:
- Journal Article
- Title:
- Comparing the usefulness of a new algorithm to measure visual field using the variational Bayes linear regression in glaucoma patients, in comparison to the Swedish interactive thresholding algorithm. Issue 5 (13th January 2021)
- Main Title:
- Comparing the usefulness of a new algorithm to measure visual field using the variational Bayes linear regression in glaucoma patients, in comparison to the Swedish interactive thresholding algorithm
- Authors:
- Murata, Hiroshi
Asaoka, Ryo
Fujino, Yuri
Matsuura, Masato
Hirasawa, Kazunori
Shimada, Satoshi
Shoji, Nobuyuki - Abstract:
- Abstract : Background/aims: We previously reported that the visual field (VF) prediction model using the variational Bayes linear regression (VBLR) is useful for accurately predicting VF progression in glaucoma (Invest Ophthalmol Vis Sci. 2014, 2018). We constructed a VF measurement algorithm using VBLR, and the purpose of this study was to investigate its usefulness. Method: 122 eyes of 73 patients with open-angle glaucoma were included in the current study. VF measurement was performed using the currently proposed VBLR programme with AP-7700 perimetry (KOWA). VF measurements were also conducted using the Swedish interactive thresholding algorithm (SITA) standard programme with Humphrey field analyser. VF measurements were performed using the 24–2 test grid. Visual sensitivities, test–retest reproducibility and measurement duration were compared between the two algorithms. Result: Mean mean deviation (MD) values with SITA standard were −7.9 and −8.7 dB (first and second measurements), whereas those with VBLR-VF were −8.2 and −8.0 dB, respectively. There were no significant differences across these values. The correlation coefficient of MD values between the 2 algorithms was 0.97 or 0.98. Test–retest reproducibility did not differ between the two algorithms. Mean measurement duration with SITA standard was 6 min and 02 s or 6 min and 00 s (first or second measurement), whereas a significantly shorter duration was associated with VBLR-VF (5 min and 23 s or 5 min and 30 s).Abstract : Background/aims: We previously reported that the visual field (VF) prediction model using the variational Bayes linear regression (VBLR) is useful for accurately predicting VF progression in glaucoma (Invest Ophthalmol Vis Sci. 2014, 2018). We constructed a VF measurement algorithm using VBLR, and the purpose of this study was to investigate its usefulness. Method: 122 eyes of 73 patients with open-angle glaucoma were included in the current study. VF measurement was performed using the currently proposed VBLR programme with AP-7700 perimetry (KOWA). VF measurements were also conducted using the Swedish interactive thresholding algorithm (SITA) standard programme with Humphrey field analyser. VF measurements were performed using the 24–2 test grid. Visual sensitivities, test–retest reproducibility and measurement duration were compared between the two algorithms. Result: Mean mean deviation (MD) values with SITA standard were −7.9 and −8.7 dB (first and second measurements), whereas those with VBLR-VF were −8.2 and −8.0 dB, respectively. There were no significant differences across these values. The correlation coefficient of MD values between the 2 algorithms was 0.97 or 0.98. Test–retest reproducibility did not differ between the two algorithms. Mean measurement duration with SITA standard was 6 min and 02 s or 6 min and 00 s (first or second measurement), whereas a significantly shorter duration was associated with VBLR-VF (5 min and 23 s or 5 min and 30 s). Conclusion: VBLR-VF reduced test duration while maintaining the same accuracy as the SITA-standard. … (more)
- Is Part Of:
- British journal of ophthalmology. Volume 106:Issue 5(2022)
- Journal:
- British journal of ophthalmology
- Issue:
- Volume 106:Issue 5(2022)
- Issue Display:
- Volume 106, Issue 5 (2022)
- Year:
- 2022
- Volume:
- 106
- Issue:
- 5
- Issue Sort Value:
- 2022-0106-0005-0000
- Page Start:
- 660
- Page End:
- 666
- Publication Date:
- 2021-01-13
- Subjects:
- field of vision -- glaucoma
Ophthalmology -- Periodicals
617.7 - Journal URLs:
- http://bjo.bmj.com/ ↗
http://bjo.bmjjournals.com/ ↗
http://www.bmj.com/archive ↗ - DOI:
- 10.1136/bjophthalmol-2020-318304 ↗
- Languages:
- English
- ISSNs:
- 0007-1161
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 26370.xml