Outcomes of enucleation and porous polyethylene orbital implant insertion in patients with paediatric retinoblastoma: a long-term follow-up study. Issue 4 (8th December 2020)
- Record Type:
- Journal Article
- Title:
- Outcomes of enucleation and porous polyethylene orbital implant insertion in patients with paediatric retinoblastoma: a long-term follow-up study. Issue 4 (8th December 2020)
- Main Title:
- Outcomes of enucleation and porous polyethylene orbital implant insertion in patients with paediatric retinoblastoma: a long-term follow-up study
- Authors:
- Yang, Min Kyu
Lee, Min Joung
Kim, Namju
Choung, Hokyung
Khwarg, Sang In - Abstract:
- Abstract : Background/Aims: To report the long-term outcomes of enucleation and insertion of porous polyethylene (PP) orbital implant according to the evolving surgical techniques and implant in patients with paediatric retinoblastoma . Methods: Patients with paediatric retinoblastoma who underwent enucleation and PP implant insertion from December 1998 to December 2014 were retrospectively reviewed and divided into four groups: group A, classic enucleation +PP implant; group B, enucleation +PP implant +anterior closure of the posterior Tenon's (ACPT) capsule; group C, enucleation +PP implant +free orbital fat graft +ACPT and group D, enucleation +smooth surface tunnel PP implant +ACPT. Survival analysis of implant exposure and eyelid malpositions was performed. Results: One hundred and ninety-eight eyes of 196 patients were included. The median follow-up period was 13.0 years (range, 5.0–21.1). A 20 mm implant was inserted for 149 eyes (75.3%). The 10-year exposure-free survival probabilities were 44.6% in group A, 96.4% in group B, 97.4% in group C and 97.7% in group D. ACPT was associated with significant reduction in implant exposure (p<0.001). The most common eyelid malposition was upper eyelid ptosis (24.2%). The eyelid malposition-free survival probability did not differ among the four groups. However, the insertion of a 20 mm implant was associated with significant reduction in upper eyelid ptosis and lower eyelid entropion (p=0.004 and 0.038, respectively).Abstract : Background/Aims: To report the long-term outcomes of enucleation and insertion of porous polyethylene (PP) orbital implant according to the evolving surgical techniques and implant in patients with paediatric retinoblastoma . Methods: Patients with paediatric retinoblastoma who underwent enucleation and PP implant insertion from December 1998 to December 2014 were retrospectively reviewed and divided into four groups: group A, classic enucleation +PP implant; group B, enucleation +PP implant +anterior closure of the posterior Tenon's (ACPT) capsule; group C, enucleation +PP implant +free orbital fat graft +ACPT and group D, enucleation +smooth surface tunnel PP implant +ACPT. Survival analysis of implant exposure and eyelid malpositions was performed. Results: One hundred and ninety-eight eyes of 196 patients were included. The median follow-up period was 13.0 years (range, 5.0–21.1). A 20 mm implant was inserted for 149 eyes (75.3%). The 10-year exposure-free survival probabilities were 44.6% in group A, 96.4% in group B, 97.4% in group C and 97.7% in group D. ACPT was associated with significant reduction in implant exposure (p<0.001). The most common eyelid malposition was upper eyelid ptosis (24.2%). The eyelid malposition-free survival probability did not differ among the four groups. However, the insertion of a 20 mm implant was associated with significant reduction in upper eyelid ptosis and lower eyelid entropion (p=0.004 and 0.038, respectively). Conclusions: The long-term postenucleation implant exposure was rare after PP implant insertion and ACPT, even with a 20 mm-diameter implant. A larger implant can be beneficial in long-term prevention of eyelid malposition. … (more)
- Is Part Of:
- British journal of ophthalmology. Volume 106:Issue 4(2022)
- Journal:
- British journal of ophthalmology
- Issue:
- Volume 106:Issue 4(2022)
- Issue Display:
- Volume 106, Issue 4 (2022)
- Year:
- 2022
- Volume:
- 106
- Issue:
- 4
- Issue Sort Value:
- 2022-0106-0004-0000
- Page Start:
- 502
- Page End:
- 509
- Publication Date:
- 2020-12-08
- Subjects:
- eye (globe) -- orbit -- neoplasia -- treatment surgery
Ophthalmology -- Periodicals
617.7 - Journal URLs:
- http://bjo.bmj.com/ ↗
http://bjo.bmjjournals.com/ ↗
http://www.bmj.com/archive ↗ - DOI:
- 10.1136/bjophthalmol-2020-317934 ↗
- Languages:
- English
- ISSNs:
- 0007-1161
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 26362.xml