Patient‐specific effects on sonication heating efficiency during magnetic resonance‐guided focused ultrasound thalamotomy. Issue 11 (29th September 2021)
- Record Type:
- Journal Article
- Title:
- Patient‐specific effects on sonication heating efficiency during magnetic resonance‐guided focused ultrasound thalamotomy. Issue 11 (29th September 2021)
- Main Title:
- Patient‐specific effects on sonication heating efficiency during magnetic resonance‐guided focused ultrasound thalamotomy
- Authors:
- Yang, Andrew I.
Hitti, Frederick L.
Alabi, Opeyemi O.
Joshi, Disha
Chaibainou, Hanane
Henry, Lenora
Clanton, Ryan
Baltuch, Gordon H. - Abstract:
- Abstract: Purpose: During magnetic resonance‐guided focused ultrasound (MRgFUS) thalamotomy for refractory tremor, high temperatures must be achieved and sustained for tissue necrosis. We assessed the impact of both patient‐specific as well as procedure‐related factors on the efficiency of acoustic energy transfer, or heating efficiency (HE). Methods: Retrospective analysis of 92 consecutive patients (857 sonications) with essential tremor or tremor‐dominant Parkinson's disease treated at a single institution. Temperature elevations at the target were measured for each sonication with MR thermometry. HE of each sonication was defined as the ratio of peak temperature elevation and the delivered energy. HE was analyzed with respect to patient skull features (area, thickness, skull density ratio [SDR]), computed from CT scans, as well as demographic and clinical variables (age, sex, diagnosis, and duration of symptoms). Results: Across the full range of sonication energies that can be delivered with current devices (up to 36 kJ), average sonication HE was diminished in patients with lower SDR. In individual subjects, there was a progressive loss in HE as sonication energy was titrated up throughout the course of treatment, with a more rapid decline in patients with higher SDR. This energy‐dependent loss in HE was not related to procedural factors, namely, the number of previous sonications, or the cumulative energy deposited during previous sonications. In contrast to SDR,Abstract: Purpose: During magnetic resonance‐guided focused ultrasound (MRgFUS) thalamotomy for refractory tremor, high temperatures must be achieved and sustained for tissue necrosis. We assessed the impact of both patient‐specific as well as procedure‐related factors on the efficiency of acoustic energy transfer, or heating efficiency (HE). Methods: Retrospective analysis of 92 consecutive patients (857 sonications) with essential tremor or tremor‐dominant Parkinson's disease treated at a single institution. Temperature elevations at the target were measured for each sonication with MR thermometry. HE of each sonication was defined as the ratio of peak temperature elevation and the delivered energy. HE was analyzed with respect to patient skull features (area, thickness, skull density ratio [SDR]), computed from CT scans, as well as demographic and clinical variables (age, sex, diagnosis, and duration of symptoms). Results: Across the full range of sonication energies that can be delivered with current devices (up to 36 kJ), average sonication HE was diminished in patients with lower SDR. In individual subjects, there was a progressive loss in HE as sonication energy was titrated up throughout the course of treatment, with a more rapid decline in patients with higher SDR. This energy‐dependent loss in HE was not related to procedural factors, namely, the number of previous sonications, or the cumulative energy deposited during previous sonications. In contrast to SDR, neither skull area nor thickness was an independent predictor of average HE or the rate of its decline with increasing energies. In 11% of patients, all of whom with SDR < 0.45, sonication HE fell below the threshold to reach 54°C even with delivery of maximum energy. In contrast, temperatures ≥ 50°C could be obtained in all but one patient. Conclusions: SDR is predictive of sonication HE, and determines patient‐specific limits on the magnitude of temperature elevation that can be achieved with current devices. These data inform strategies for predictable lesioning in MRgFUS thalamotomy. … (more)
- Is Part Of:
- Medical physics. Volume 48:Issue 11(2021)
- Journal:
- Medical physics
- Issue:
- Volume 48:Issue 11(2021)
- Issue Display:
- Volume 48, Issue 11 (2021)
- Year:
- 2021
- Volume:
- 48
- Issue:
- 11
- Issue Sort Value:
- 2021-0048-0011-0000
- Page Start:
- 6588
- Page End:
- 6596
- Publication Date:
- 2021-09-29
- Subjects:
- essential tremor -- magnetic resonance‐guided focused ultrasound -- MRgFUS -- skull density ratio -- thalamotomy
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1002/mp.15239 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 26360.xml