Comparison of two devices for automated oxygen control in preterm infants: a randomised crossover trial. Issue 1 (10th June 2021)
- Record Type:
- Journal Article
- Title:
- Comparison of two devices for automated oxygen control in preterm infants: a randomised crossover trial. Issue 1 (10th June 2021)
- Main Title:
- Comparison of two devices for automated oxygen control in preterm infants: a randomised crossover trial
- Authors:
- Salverda, Hylke H
Cramer, Sophie J E
Witlox, Ruben S G M
Gale, Timothy J
Dargaville, Peter A
Pauws, Steffen C
te Pas, Arjan B - Abstract:
- Abstract : Objective: To compare the effect of two different automated oxygen control devices on target range (TR) time and occurrence of hypoxaemic and hyperoxaemic episodes. Design: Randomised cross-over study. Setting: Tertiary level neonatal unit in the Netherlands. Patients: Preterm infants (n=15) born between 24+0 and 29+6 days of gestation, receiving invasive or non-invasive respiratory support with oxygen saturation (SpO2 ) TR of 91%–95%. Median gestational age 26 weeks and 4 days (IQR 25 weeks 3 days–27 weeks 6 days) and postnatal age 19 (IQR 17–24) days. Interventions: Inspired oxygen concentration was titrated by the OxyGenie controller (SLE6000 ventilator) and the CLiO2 controller (AVEA ventilator) for 24 hours each, in a random sequence, with the respiratory support mode kept constant. Main outcome measures: Time spent within set SpO2 TR (91%–95% with supplemental oxygen and 91%–100% without supplemental oxygen). Results: Time spent within the SpO2 TR was higher during OxyGenie control (80.2 (72.6–82.4)% vs 68.5 (56.7–79.3)%, p<0.005). Less time was spent above TR while in supplemental oxygen (6.3 (5.1–9.9)% vs 15.9 (11.5–30.7)%, p<0.005) but more time spent below TR during OxyGenie control (14.7 (11.8%–17.2%) vs 9.3 (8.2–12.6)%, p<0.05). There was no significant difference in time with SpO2 <80% (0.5 (0.1–1.0)% vs 0.2 (0.1–0.4)%, p=0.061). Long-lasting SpO2 deviations occurred less frequently during OxyGenie control. Conclusions: The OxyGenie control algorithmAbstract : Objective: To compare the effect of two different automated oxygen control devices on target range (TR) time and occurrence of hypoxaemic and hyperoxaemic episodes. Design: Randomised cross-over study. Setting: Tertiary level neonatal unit in the Netherlands. Patients: Preterm infants (n=15) born between 24+0 and 29+6 days of gestation, receiving invasive or non-invasive respiratory support with oxygen saturation (SpO2 ) TR of 91%–95%. Median gestational age 26 weeks and 4 days (IQR 25 weeks 3 days–27 weeks 6 days) and postnatal age 19 (IQR 17–24) days. Interventions: Inspired oxygen concentration was titrated by the OxyGenie controller (SLE6000 ventilator) and the CLiO2 controller (AVEA ventilator) for 24 hours each, in a random sequence, with the respiratory support mode kept constant. Main outcome measures: Time spent within set SpO2 TR (91%–95% with supplemental oxygen and 91%–100% without supplemental oxygen). Results: Time spent within the SpO2 TR was higher during OxyGenie control (80.2 (72.6–82.4)% vs 68.5 (56.7–79.3)%, p<0.005). Less time was spent above TR while in supplemental oxygen (6.3 (5.1–9.9)% vs 15.9 (11.5–30.7)%, p<0.005) but more time spent below TR during OxyGenie control (14.7 (11.8%–17.2%) vs 9.3 (8.2–12.6)%, p<0.05). There was no significant difference in time with SpO2 <80% (0.5 (0.1–1.0)% vs 0.2 (0.1–0.4)%, p=0.061). Long-lasting SpO2 deviations occurred less frequently during OxyGenie control. Conclusions: The OxyGenie control algorithm was more effective in keeping the oxygen saturation within TR and preventing hyperoxaemia and equally effective in preventing hypoxaemia (SpO2 <80%), although at the cost of a small increase in mild hypoxaemia. Trial registry number: NCT03877198 … (more)
- Is Part Of:
- Archives of disease in childhood. Volume 107:Issue 1(2022)
- Journal:
- Archives of disease in childhood
- Issue:
- Volume 107:Issue 1(2022)
- Issue Display:
- Volume 107, Issue 1 (2022)
- Year:
- 2022
- Volume:
- 107
- Issue:
- 1
- Issue Sort Value:
- 2022-0107-0001-0000
- Page Start:
- 20
- Page End:
- 25
- Publication Date:
- 2021-06-10
- Subjects:
- neonatology -- technology
Infants -- Diseases -- Periodicals
Newborn infants -- Diseases -- Periodicals
Fetus -- Diseases -- Periodicals
618.920105 - Journal URLs:
- http://fn.bmjjournals.com ↗
http://www.bmj.com/archive ↗ - DOI:
- 10.1136/archdischild-2020-321387 ↗
- Languages:
- English
- ISSNs:
- 1359-2998
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 26350.xml