Accuracy of computer‐assisted, template‐guided implant placement compared with conventional implant placement by hand—An in vitro study. Issue 9 (28th June 2021)
- Record Type:
- Journal Article
- Title:
- Accuracy of computer‐assisted, template‐guided implant placement compared with conventional implant placement by hand—An in vitro study. Issue 9 (28th June 2021)
- Main Title:
- Accuracy of computer‐assisted, template‐guided implant placement compared with conventional implant placement by hand—An in vitro study
- Authors:
- Schneider, David
Sax, Caroline
Sancho‐Puchades, Manuel
Hämmerle, Christoph H.F.
Jung, Ronald Ernst - Abstract:
- Abstract: Objectives: To compare free‐hand to computer‐assisted implant planning and placement (CAIPP) regarding planned to achieved implant position. Material and methods: Forty‐eight cast/bone models were mounted in mannequin heads. On each side, a tooth gap of different sizes was created. In the test group (T), study implants were placed using a CAD‐CAM guide based on virtual planning. In the control (C), free‐hand implant placement was performed. After CBCT scanning, the implant position was compared with the planned position. Descriptive statistics were applied, and ANOVA was used to identify differences between groups and gaps. ( p < .05). Results: In C, mean lateral deviations at the implant base amounted to 0.7 mm (max. 1.8) (large gap) and 0.49 mm (1.22) (small gap). In T, 0.18 mm (0.49) and 0.24 mm (0.52) were recorded. At the apex, 0.77 mm (2.04) (large gap) and 0.51 mm (1.24) (small gap) were measured in C, and 0.31 mm (0.83)/0.34 mm (0.93) in T. Mean vertical deviations in C measured 0.46 mm (1.26) (large gap) and 0.45 mm (1.7) (small gap). In T, 0.14 mm (0.44) and 0.28 mm (0.78) were recorded. Mean angular deviations of 1.7° (3.2°) were observed in C (large gap) and 1.36° (2.1°) (small gap). In T, mean values were 1.57° (3.3°) and 1.32° (3.4°). Lateral and vertical deviations were significantly different between groups (not gaps), angular between gaps (not groups). Conclusions: CAIPP protocols showed smaller deviations irrespective of the size of the toothAbstract: Objectives: To compare free‐hand to computer‐assisted implant planning and placement (CAIPP) regarding planned to achieved implant position. Material and methods: Forty‐eight cast/bone models were mounted in mannequin heads. On each side, a tooth gap of different sizes was created. In the test group (T), study implants were placed using a CAD‐CAM guide based on virtual planning. In the control (C), free‐hand implant placement was performed. After CBCT scanning, the implant position was compared with the planned position. Descriptive statistics were applied, and ANOVA was used to identify differences between groups and gaps. ( p < .05). Results: In C, mean lateral deviations at the implant base amounted to 0.7 mm (max. 1.8) (large gap) and 0.49 mm (1.22) (small gap). In T, 0.18 mm (0.49) and 0.24 mm (0.52) were recorded. At the apex, 0.77 mm (2.04) (large gap) and 0.51 mm (1.24) (small gap) were measured in C, and 0.31 mm (0.83)/0.34 mm (0.93) in T. Mean vertical deviations in C measured 0.46 mm (1.26) (large gap) and 0.45 mm (1.7) (small gap). In T, 0.14 mm (0.44) and 0.28 mm (0.78) were recorded. Mean angular deviations of 1.7° (3.2°) were observed in C (large gap) and 1.36° (2.1°) (small gap). In T, mean values were 1.57° (3.3°) and 1.32° (3.4°). Lateral and vertical deviations were significantly different between groups (not gaps), angular between gaps (not groups). Conclusions: CAIPP protocols showed smaller deviations irrespective of the size of the tooth gap. In C, the gap size had an influence on the error in angulation only. … (more)
- Is Part Of:
- Clinical oral implants research. Volume 32:Issue 9(2021)
- Journal:
- Clinical oral implants research
- Issue:
- Volume 32:Issue 9(2021)
- Issue Display:
- Volume 32, Issue 9 (2021)
- Year:
- 2021
- Volume:
- 32
- Issue:
- 9
- Issue Sort Value:
- 2021-0032-0009-0000
- Page Start:
- 1052
- Page End:
- 1060
- Publication Date:
- 2021-06-28
- Subjects:
- computer‐assisted implantology -- digital dentistry -- guided surgery
Dental implants -- Research -- Periodicals
617.69 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1111/clr.13799 ↗
- Languages:
- English
- ISSNs:
- 0905-7161
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.318000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 26351.xml