Real-time continuous measurement of lactate through a minimally invasive microneedle patch: a phase I clinical study. Issue 2 (28th February 2022)
- Record Type:
- Journal Article
- Title:
- Real-time continuous measurement of lactate through a minimally invasive microneedle patch: a phase I clinical study. Issue 2 (28th February 2022)
- Main Title:
- Real-time continuous measurement of lactate through a minimally invasive microneedle patch: a phase I clinical study
- Authors:
- Ming, Damien K
Jangam, Saylee
Gowers, Sally A N
Wilson, Richard
Freeman, David M E
Boutelle, Martyn G
Cass, Anthony E G
O'Hare, Danny
Holmes, Alison H - Abstract:
- Abstract : Introduction: Determination of blood lactate levels supports decision-making in a range of medical conditions. Invasive blood-sampling and laboratory access are often required, and measurements provide a static profile at each instance. We conducted a phase I clinical study validating performance of a microneedle patch for minimally invasive, continuous lactate measurement in healthy volunteers. Methods: Five healthy adult participants wore a solid microneedle biosensor patch on their forearms and undertook aerobic exercise for 30 min. The microneedle biosensor quantifies lactate concentrations in interstitial fluid within the dermis continuously and in real-time. Outputs were captured as sensor current and compared with lactate concentrations from venous blood and microdialysis. Results: The biosensor was well-tolerated. Participants generated a median peak venous lactate of 9.25 mmol/L (IQR 6.73–10.71). Microdialysate concentrations of lactate closely correlated with blood. Microneedle biosensor current followed venous lactate concentrations and dynamics, with good agreement seen in all participants. There was an estimated lag-time of 5 min (IQR −4 to 11 min) between microneedle and blood lactate measurements. Conclusion: This study provides first-in-human data on use of a minimally invasive microneedle patch for continuous lactate measurement, providing dynamic monitoring. This low-cost platform offers distinct advantages to frequent blood sampling in a wideAbstract : Introduction: Determination of blood lactate levels supports decision-making in a range of medical conditions. Invasive blood-sampling and laboratory access are often required, and measurements provide a static profile at each instance. We conducted a phase I clinical study validating performance of a microneedle patch for minimally invasive, continuous lactate measurement in healthy volunteers. Methods: Five healthy adult participants wore a solid microneedle biosensor patch on their forearms and undertook aerobic exercise for 30 min. The microneedle biosensor quantifies lactate concentrations in interstitial fluid within the dermis continuously and in real-time. Outputs were captured as sensor current and compared with lactate concentrations from venous blood and microdialysis. Results: The biosensor was well-tolerated. Participants generated a median peak venous lactate of 9.25 mmol/L (IQR 6.73–10.71). Microdialysate concentrations of lactate closely correlated with blood. Microneedle biosensor current followed venous lactate concentrations and dynamics, with good agreement seen in all participants. There was an estimated lag-time of 5 min (IQR −4 to 11 min) between microneedle and blood lactate measurements. Conclusion: This study provides first-in-human data on use of a minimally invasive microneedle patch for continuous lactate measurement, providing dynamic monitoring. This low-cost platform offers distinct advantages to frequent blood sampling in a wide range of clinical settings, especially where access to laboratory services is limited or blood sampling is infeasible. Implementation of this technology in healthcare settings could support personalised decision-making in a variety of hospital and community settings. Trial registration number: NCT04238611 . … (more)
- Is Part Of:
- BMJ innovations. Volume 8:Issue 2(2022)
- Journal:
- BMJ innovations
- Issue:
- Volume 8:Issue 2(2022)
- Issue Display:
- Volume 8, Issue 2 (2022)
- Year:
- 2022
- Volume:
- 8
- Issue:
- 2
- Issue Sort Value:
- 2022-0008-0002-0000
- Page Start:
- 87
- Page End:
- 94
- Publication Date:
- 2022-02-28
- Subjects:
- diagnosis -- clinical decision-making -- biomedical engineering -- patient care -- infectious disease medicine
Medicine -- Research -- Periodicals
610.72 - Journal URLs:
- http://www.bmj.com/archive ↗
http://innovations.bmj.com/ ↗ - DOI:
- 10.1136/bmjinnov-2021-000864 ↗
- Languages:
- English
- ISSNs:
- 2055-8074
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 26323.xml