Multicenter Experience Using Collagen Fleece for Plaque Incision with Grafting to Correct Residual Curvature at the Time of Inflatable Penile Prosthesis Placement in Patients with Peyronie's Disease. Issue 6 (18th March 2020)
- Record Type:
- Journal Article
- Title:
- Multicenter Experience Using Collagen Fleece for Plaque Incision with Grafting to Correct Residual Curvature at the Time of Inflatable Penile Prosthesis Placement in Patients with Peyronie's Disease. Issue 6 (18th March 2020)
- Main Title:
- Multicenter Experience Using Collagen Fleece for Plaque Incision with Grafting to Correct Residual Curvature at the Time of Inflatable Penile Prosthesis Placement in Patients with Peyronie's Disease
- Authors:
- Hatzichristodoulou, Georgios
Yang, David Y.
Ring, Joshua D.
Hebert, Kevin J.
Ziegelman, Matthew J.
Köhler, Tobias S. - Abstract:
- Abstract: Background: Adjuvant maneuvers are often necessary to correct residual curvature during inflatable penile prosthesis (IPP) placement in patients with Peyronie's disease (PD). Aim: We present our multicenter experience using collagen fleece as graft material for plaque incision and grafting (PIG) during IPP placement in patients with moderate to severe PD. Methods: We retrospectively reviewed 51 patients with IPP from 3 sites who underwent PIG with Tachosil (Baxter, IL) collagen fleece. Coloplast (Minneapolis, MN) IPP devices were used. Factors associated with residual curvature, revision, and patient satisfaction were performed using chi-squared analysis. Outcomes: We evaluated postoperative outcomes including factors associated with residual curvature, revision, and patient satisfaction. Results: The mean compound curvature was 69.6°. The mean follow-up was 10.6 (range 1–38) months. All patients reported erections sufficient for penetrative intercourse at the last follow-up. Residual curvature <15° was noted in 6 of 51 (12%) patients. 3 patients required device revision. 2 patients experienced temporary glanular paresthesia, and no patients experienced device infection. Clinical Implications: In our multicenter study, patients experienced substantial curve correction with minimal complications, and in the few patients who had persistent mild curvature, severe preoperative curvature (>60°) was found to be the only risk factor. Strengths & Limitations: Our studyAbstract: Background: Adjuvant maneuvers are often necessary to correct residual curvature during inflatable penile prosthesis (IPP) placement in patients with Peyronie's disease (PD). Aim: We present our multicenter experience using collagen fleece as graft material for plaque incision and grafting (PIG) during IPP placement in patients with moderate to severe PD. Methods: We retrospectively reviewed 51 patients with IPP from 3 sites who underwent PIG with Tachosil (Baxter, IL) collagen fleece. Coloplast (Minneapolis, MN) IPP devices were used. Factors associated with residual curvature, revision, and patient satisfaction were performed using chi-squared analysis. Outcomes: We evaluated postoperative outcomes including factors associated with residual curvature, revision, and patient satisfaction. Results: The mean compound curvature was 69.6°. The mean follow-up was 10.6 (range 1–38) months. All patients reported erections sufficient for penetrative intercourse at the last follow-up. Residual curvature <15° was noted in 6 of 51 (12%) patients. 3 patients required device revision. 2 patients experienced temporary glanular paresthesia, and no patients experienced device infection. Clinical Implications: In our multicenter study, patients experienced substantial curve correction with minimal complications, and in the few patients who had persistent mild curvature, severe preoperative curvature (>60°) was found to be the only risk factor. Strengths & Limitations: Our study represents the largest series of patients coming from multiple centers undergoing surgical correction of PD with IPP and collagen fleece grafting. Limitations of this study include the retrospective study design, lack of a comparison group, and modest follow-up. Conclusion: PIG using collagen fleece is a safe and effective means of correcting residual curvature after IPP placement in patients with moderate to severe PD. … (more)
- Is Part Of:
- Journal of sexual medicine. Volume 17:Issue 6(2020)
- Journal:
- Journal of sexual medicine
- Issue:
- Volume 17:Issue 6(2020)
- Issue Display:
- Volume 17, Issue 6 (2020)
- Year:
- 2020
- Volume:
- 17
- Issue:
- 6
- Issue Sort Value:
- 2020-0017-0006-0000
- Page Start:
- 1168
- Page End:
- 1174
- Publication Date:
- 2020-03-18
- Subjects:
- Peyronie's Disease -- Plaque Incision With Grafting -- Erectile Dysfunction -- Collagen Fleece -- Penile Prosthesis
Sexual disorders -- Periodicals
Sex -- Periodicals
Sexual health -- Periodicals
616.69005 - Journal URLs:
- http://firstsearch.oclc.org ↗
http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1743-6109 ↗
http://www.blackwell-synergy.com/openurl?genre=journal&eissn=1743-6109 ↗
http://www.blackwell-synergy.com/servlet/useragent?func=showIssues&code=jsm ↗
https://academic.oup.com/jsm ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1016/j.jsxm.2020.02.019 ↗
- Languages:
- English
- ISSNs:
- 1743-6095
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5064.060000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 26338.xml