Circle of Willis variants and their association with outcome in patients with middle cerebral artery‐M1‐occlusion stroke. (6th August 2021)
- Record Type:
- Journal Article
- Title:
- Circle of Willis variants and their association with outcome in patients with middle cerebral artery‐M1‐occlusion stroke. (6th August 2021)
- Main Title:
- Circle of Willis variants and their association with outcome in patients with middle cerebral artery‐M1‐occlusion stroke
- Authors:
- Westphal, Laura P.
Lohaus, Niklas
Winklhofer, Sebastian
Manzolini, Christian
Held, Ulrike
Steigmiller, Klaus
Hamann, Janne M.
El Amki, Mohamad
Dobrocky, Tomas
Panos, Leonidas D.
Kaesmacher, Johannes
Fischer, Urs
Heldner, Mirjam R.
Luft, Andreas R.
Gralla, Jan
Arnold, Marcel
Wiest, Roland
Wegener, Susanne - Abstract:
- Abstract: Background: An incomplete circle of Willis (CoW) has been associated with a higher risk of stroke and might affect collateral flow in large vessel occlusion (LVO) stroke. We aimed to investigate the distribution of CoW variants in a LVO stroke and transient ischemic attack (TIA) cohort and analyze their impact on 3‐month functional outcome. Methods: CoW anatomy was assessed with time‐of‐flight magnetic resonance angiography (TOF‐MRA) in 193 stroke patients with acute middle cerebral artery (MCA)‐M1‐occlusion receiving endovascular treatment (EVT) and 73 TIA patients without LVO. The main CoW variants were categorized into four vascular models of presumed collateral flow via the CoW. Results: 82.4% ( n = 159) of stroke and 72.6% ( n = 53) of TIA patients had an incomplete CoW. Most variants affected the posterior circulation (stroke: 77.2%, n = 149; TIA: 58.9%, n = 43; p = 0.004). Initial stroke severity defined by the National Institutes of Health Stroke Scale (NIHSS) on admission was similar for patients with and without CoW variants. CoW integrity did not differ between groups with favorable (modified Rankin Scale [mRS]): 0–2) and unfavorable (mRS: 3–6) 3‐month outcome. However, we found trends towards a higher mortality in patients with any type of CoW variant ( p = 0.08) and a higher frequency of incomplete CoW among patients dying within 3 months after stroke onset ( p = 0.119). In a logistic regression analysis adjusted for the potential confoundersAbstract: Background: An incomplete circle of Willis (CoW) has been associated with a higher risk of stroke and might affect collateral flow in large vessel occlusion (LVO) stroke. We aimed to investigate the distribution of CoW variants in a LVO stroke and transient ischemic attack (TIA) cohort and analyze their impact on 3‐month functional outcome. Methods: CoW anatomy was assessed with time‐of‐flight magnetic resonance angiography (TOF‐MRA) in 193 stroke patients with acute middle cerebral artery (MCA)‐M1‐occlusion receiving endovascular treatment (EVT) and 73 TIA patients without LVO. The main CoW variants were categorized into four vascular models of presumed collateral flow via the CoW. Results: 82.4% ( n = 159) of stroke and 72.6% ( n = 53) of TIA patients had an incomplete CoW. Most variants affected the posterior circulation (stroke: 77.2%, n = 149; TIA: 58.9%, n = 43; p = 0.004). Initial stroke severity defined by the National Institutes of Health Stroke Scale (NIHSS) on admission was similar for patients with and without CoW variants. CoW integrity did not differ between groups with favorable (modified Rankin Scale [mRS]): 0–2) and unfavorable (mRS: 3–6) 3‐month outcome. However, we found trends towards a higher mortality in patients with any type of CoW variant ( p = 0.08) and a higher frequency of incomplete CoW among patients dying within 3 months after stroke onset ( p = 0.119). In a logistic regression analysis adjusted for the potential confounders age, sex and atrial fibrillation, neither the vascular models nor anterior or posterior variants were independently associated with outcome. Conclusion: Our data provide no evidence for an association of CoW variants with clinical outcome in LVO stroke patients receiving EVT. Abstract : An incomplete circle of Willis (CoW) has been associated with a higher risk of stroke and might affect collateral flow in large vessel occlusion (LVO) stroke. We aimed to investigate the distribution of CoW variants in a LVO stroke and transient ischemic attack cohort and analyze their impact on 3‐month functional outcome … (more)
- Is Part Of:
- European journal of neurology. Volume 28:Number 11(2021)
- Journal:
- European journal of neurology
- Issue:
- Volume 28:Number 11(2021)
- Issue Display:
- Volume 28, Issue 11 (2021)
- Year:
- 2021
- Volume:
- 28
- Issue:
- 11
- Issue Sort Value:
- 2021-0028-0011-0000
- Page Start:
- 3682
- Page End:
- 3691
- Publication Date:
- 2021-08-06
- Subjects:
- anatomical variants -- circle of Willis -- collaterals -- stroke -- TOF‐MRA
Neurology -- Periodicals
Nervous system -- Diseases -- Periodicals
616.8 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1468-1331 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/ene.15013 ↗
- Languages:
- English
- ISSNs:
- 1351-5101
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.731680
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 26288.xml