Clinical Evaluation of a Novel Laser-Ablated Titanium Implant System for Bone Anchored Hearing Systems in a Pediatric Population and the Relationship of Resonance Frequency Analysis With Implant Survival. Issue 2 (February 2022)
- Record Type:
- Journal Article
- Title:
- Clinical Evaluation of a Novel Laser-Ablated Titanium Implant System for Bone Anchored Hearing Systems in a Pediatric Population and the Relationship of Resonance Frequency Analysis With Implant Survival. Issue 2 (February 2022)
- Main Title:
- Clinical Evaluation of a Novel Laser-Ablated Titanium Implant System for Bone Anchored Hearing Systems in a Pediatric Population and the Relationship of Resonance Frequency Analysis With Implant Survival
- Authors:
- Osborne, Max Sallis
Child-Hymas, Anne
Holmberg, Marcus
Thomsen, Peter
Johansson, Martin L.
McDermott, Ann-Louise - Abstract:
- Abstract : Objective: To evaluate the clinical outcomes of pediatric patients implanted a novel 4.5 mm wide laser ablated titanium bone anchored implant system and to evaluate the implant stability over the first 12-month period. Study Design: A prospective, single-subject, repeated measure, cohort study. Participants served as their own controls. Setting: Community and tertiary referral hospital pediatric assessment center. Patients: A total of 115 consecutive pediatric patients aged 4 to 15 years were implanted with 176 laser ablated titanium bone anchored implants from January 2016 to January 2019. Main Outcome Measure: Clinical outcomes, implant failure rates, and post implantation implant stability quotient (ISQ) scores were studied over the first 12-month period. Data were analyzed for statistical significance through mixed effect modeling, with the significance level p = 0.01. Results: A median 12-month survival of 96.6% was observed. Six implants (3.5%) were lost in total, one of these (0.6%) was lost due to trauma. Adverse skin reactions (Holgers grade 2–4) were observed in 4.4% of all postoperative visits, occurring in 22 individuals (19.1%). Neither the ISQ high (ISQH) nor ISQ low (ISQL) values increased significantly between the stage 1 and 2 surgeries. In contrast, the ISQ results, irrespective of abutment size, demonstrated an increasing trend from 49.1 to 57 over the 12 months review period. A statistically significant change was only demonstrated from theAbstract : Objective: To evaluate the clinical outcomes of pediatric patients implanted a novel 4.5 mm wide laser ablated titanium bone anchored implant system and to evaluate the implant stability over the first 12-month period. Study Design: A prospective, single-subject, repeated measure, cohort study. Participants served as their own controls. Setting: Community and tertiary referral hospital pediatric assessment center. Patients: A total of 115 consecutive pediatric patients aged 4 to 15 years were implanted with 176 laser ablated titanium bone anchored implants from January 2016 to January 2019. Main Outcome Measure: Clinical outcomes, implant failure rates, and post implantation implant stability quotient (ISQ) scores were studied over the first 12-month period. Data were analyzed for statistical significance through mixed effect modeling, with the significance level p = 0.01. Results: A median 12-month survival of 96.6% was observed. Six implants (3.5%) were lost in total, one of these (0.6%) was lost due to trauma. Adverse skin reactions (Holgers grade 2–4) were observed in 4.4% of all postoperative visits, occurring in 22 individuals (19.1%). Neither the ISQ high (ISQH) nor ISQ low (ISQL) values increased significantly between the stage 1 and 2 surgeries. In contrast, the ISQ results, irrespective of abutment size, demonstrated an increasing trend from 49.1 to 57 over the 12 months review period. A statistically significant change was only demonstrated from the 3 months follow up onwards. Conclusion: The use of 4.5 mm wide laser-ablated titanium bone anchored hearing implants resulted in superior survival rates and excellent clinical outcomes compared with previous implant systems. … (more)
- Is Part Of:
- Otology & neurotology. Volume 43:Issue 2(2022)
- Journal:
- Otology & neurotology
- Issue:
- Volume 43:Issue 2(2022)
- Issue Display:
- Volume 43, Issue 2 (2022)
- Year:
- 2022
- Volume:
- 43
- Issue:
- 2
- Issue Sort Value:
- 2022-0043-0002-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-02
- Subjects:
- Bone conduction hearing -- Bone-anchored hearing aid -- Dental implants osseointegration -- Resonance frequency analysis
Otology -- Periodicals
Ear -- Diseases -- Periodicals
Skull base -- Surgery -- Periodicals
617.8005 - Journal URLs:
- http://www.otology-neurotology.com ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/MAO.0000000000003435 ↗
- Languages:
- English
- ISSNs:
- 1531-7129
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6313.528000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 26299.xml