Analysis of implant stability changes in immediate loading using a laser displacement sensor in vivo and comparison of its sensitivity with that of resonance frequency analysis. Issue 11 (29th August 2021)
- Record Type:
- Journal Article
- Title:
- Analysis of implant stability changes in immediate loading using a laser displacement sensor in vivo and comparison of its sensitivity with that of resonance frequency analysis. Issue 11 (29th August 2021)
- Main Title:
- Analysis of implant stability changes in immediate loading using a laser displacement sensor in vivo and comparison of its sensitivity with that of resonance frequency analysis
- Authors:
- Murakami, Kazuhiro
Yamamoto, Kazuhiko
Ishida, Junichi
Tsutsumi, Sadami
Kirita, Tadaaki - Abstract:
- Abstract: Objective: The aim of this study was to analyze the stability changes in immediately loaded implants by using an in vivo quantitative measurement of micromotion under functional dynamic loading and to verify the sensitivity of Resonance Frequency Analysis (RFA) as compared to that of actual micromotion. Materials and methods: The micromotions of immediately loaded implants placed in the tibia of 11 rabbits were monitored using a laser displacement sensor. Functional dynamic loading forces were applied 5 days a week for 6 weeks. The implant stability quotient (ISQ) was monitored using RFA. Results: The micromotion of the almost‐loaded implants increased to peak values the day after loading was started and subsequently reached a plateau gradually. The ISQ changes in the loaded implants closely correlated with the alterations of the actual micromotion ( r = −0.98, p < .01). Although the ISQ value itself correlated with the measured micromotion at the time of initial fixation ( r = 0.73, p < .05), it did not correlate with the micromotion of the implant that acquired integration. No close correlation was observed between the ISQ and the histomorphometrical data. Conclusion: The immediately loaded implants showed the lowest stability immediately after the start of loading, which gradually increased thereafter. RFA is considered a useful method for examining stability changes and initial stability; however, it cannot determine the absolute magnitude of the stabilityAbstract: Objective: The aim of this study was to analyze the stability changes in immediately loaded implants by using an in vivo quantitative measurement of micromotion under functional dynamic loading and to verify the sensitivity of Resonance Frequency Analysis (RFA) as compared to that of actual micromotion. Materials and methods: The micromotions of immediately loaded implants placed in the tibia of 11 rabbits were monitored using a laser displacement sensor. Functional dynamic loading forces were applied 5 days a week for 6 weeks. The implant stability quotient (ISQ) was monitored using RFA. Results: The micromotion of the almost‐loaded implants increased to peak values the day after loading was started and subsequently reached a plateau gradually. The ISQ changes in the loaded implants closely correlated with the alterations of the actual micromotion ( r = −0.98, p < .01). Although the ISQ value itself correlated with the measured micromotion at the time of initial fixation ( r = 0.73, p < .05), it did not correlate with the micromotion of the implant that acquired integration. No close correlation was observed between the ISQ and the histomorphometrical data. Conclusion: The immediately loaded implants showed the lowest stability immediately after the start of loading, which gradually increased thereafter. RFA is considered a useful method for examining stability changes and initial stability; however, it cannot determine the absolute magnitude of the stability after integration. … (more)
- Is Part Of:
- Clinical oral implants research. Volume 32:Issue 11(2021)
- Journal:
- Clinical oral implants research
- Issue:
- Volume 32:Issue 11(2021)
- Issue Display:
- Volume 32, Issue 11 (2021)
- Year:
- 2021
- Volume:
- 32
- Issue:
- 11
- Issue Sort Value:
- 2021-0032-0011-0000
- Page Start:
- 1341
- Page End:
- 1356
- Publication Date:
- 2021-08-29
- Subjects:
- bone histomorphometrical analysis -- dental implants -- immediate loading -- laser displacement sensor -- micromotion -- osseointegration -- rabbit -- resonance frequency analysis
Dental implants -- Research -- Periodicals
617.69 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1111/clr.13835 ↗
- Languages:
- English
- ISSNs:
- 0905-7161
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.318000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 26270.xml