Can differences in linear energy transfer and thus relative biological effectiveness compromise the dosimetric advantage of intensity-modulated proton therapy as compared to passively scattered proton therapy?. (2nd September 2018)
- Record Type:
- Journal Article
- Title:
- Can differences in linear energy transfer and thus relative biological effectiveness compromise the dosimetric advantage of intensity-modulated proton therapy as compared to passively scattered proton therapy?. (2nd September 2018)
- Main Title:
- Can differences in linear energy transfer and thus relative biological effectiveness compromise the dosimetric advantage of intensity-modulated proton therapy as compared to passively scattered proton therapy?
- Authors:
- Giantsoudi, Drosoula
Adams, Judith
MacDonald, Shannon
Paganetti, Harald - Abstract:
- Abstract: Purpose: To investigate the effect of differences in linear energy transfer (LET) and thus the relative biological effectiveness (RBE) between passively scattered proton therapy (PS) and pencil-beam scanning intensity-modulated proton therapy (IMPT). Methods: IMPT treatment plans were generated for six ependymoma patients, originally treated with PS, using the original plan's computed tomography image sets and beam directions, and its dose-volume values as optimization constraints. Two beam spot sizes and both single-field optimization (SFO) and multi-field optimization (MFO) techniques were used for each patient. Three-dimensional variable-RBE-weighted dose distributions were computed, using Monte Carlo calculated dose and LET distributions, and a linear dose and LET-based RBE model, and were compared between the two delivery methods. Results: Increased target dose coverage and decreased mean and maximum dose to the OARs was achieved with IMPT compared to PS, for constant RBE value of 1.1. Nevertheless, the maximum variable-RBE-weighted dose to the brainstem, was increased up to 6% for the IMPT plans compared to the corresponding PS plans. Conclusions: IMPT can be dosimetrically superior to PS for ependymoma patients. However, caution should be exercised so that the increased dose conformity is not counteracted by an increase in radiobiological effect in adjacent critical structures.
- Is Part Of:
- Acta oncologica. Volume 57:Number 9(2018)
- Journal:
- Acta oncologica
- Issue:
- Volume 57:Number 9(2018)
- Issue Display:
- Volume 57, Issue 9 (2018)
- Year:
- 2018
- Volume:
- 57
- Issue:
- 9
- Issue Sort Value:
- 2018-0057-0009-0000
- Page Start:
- 1259
- Page End:
- 1264
- Publication Date:
- 2018-09-02
- Subjects:
- Oncology -- Periodicals
Cancer -- Treatment -- Periodicals
616.992 - Journal URLs:
- http://informahealthcare.com/loi/onc ↗
http://informahealthcare.com ↗ - DOI:
- 10.1080/0284186X.2018.1468090 ↗
- Languages:
- English
- ISSNs:
- 0284-186X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0641.705000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 26247.xml