A high‐density 256‐channel cap for dry electroencephalography. Issue 4 (19th November 2021)
- Record Type:
- Journal Article
- Title:
- A high‐density 256‐channel cap for dry electroencephalography. Issue 4 (19th November 2021)
- Main Title:
- A high‐density 256‐channel cap for dry electroencephalography
- Authors:
- Fiedler, Patrique
Fonseca, Carlos
Supriyanto, Eko
Zanow, Frank
Haueisen, Jens - Abstract:
- Abstract: High‐density electroencephalography (HD‐EEG) is currently limited to laboratory environments since state‐of‐the‐art electrode caps require skilled staff and extensive preparation. We propose and evaluate a 256‐channel cap with dry multipin electrodes for HD‐EEG. We describe the designs of the dry electrodes made from polyurethane and coated with Ag/AgCl. We compare in a study with 30 volunteers the novel dry HD‐EEG cap to a conventional gel‐based cap for electrode‐skin impedances, resting state EEG, and visual evoked potentials (VEP). We perform wearing tests with eight electrodes mimicking cap applications on real human and artificial skin. Average impedances below 900 kΩ for 252 out of 256 dry electrodes enables recording with state‐of‐the‐art EEG amplifiers. For the dry EEG cap, we obtained a channel reliability of 84% and a reduction of the preparation time of 69%. After exclusion of an average of 16% (dry) and 3% (gel‐based) bad channels, resting state EEG, alpha activity, and pattern reversal VEP can be recorded with less than 5% significant differences in all compared signal characteristics metrics. Volunteers reported wearing comfort of 3.6 ± 1.5 and 4.0 ± 1.8 for the dry and 2.5 ± 1.0 and 3.0 ± 1.1 for the gel‐based cap prior and after the EEG recordings, respectively (scale 1–10). Wearing tests indicated that up to 3, 200 applications are possible for the dry electrodes. The 256‐channel HD‐EEG dry electrode cap overcomes the principal limitations ofAbstract: High‐density electroencephalography (HD‐EEG) is currently limited to laboratory environments since state‐of‐the‐art electrode caps require skilled staff and extensive preparation. We propose and evaluate a 256‐channel cap with dry multipin electrodes for HD‐EEG. We describe the designs of the dry electrodes made from polyurethane and coated with Ag/AgCl. We compare in a study with 30 volunteers the novel dry HD‐EEG cap to a conventional gel‐based cap for electrode‐skin impedances, resting state EEG, and visual evoked potentials (VEP). We perform wearing tests with eight electrodes mimicking cap applications on real human and artificial skin. Average impedances below 900 kΩ for 252 out of 256 dry electrodes enables recording with state‐of‐the‐art EEG amplifiers. For the dry EEG cap, we obtained a channel reliability of 84% and a reduction of the preparation time of 69%. After exclusion of an average of 16% (dry) and 3% (gel‐based) bad channels, resting state EEG, alpha activity, and pattern reversal VEP can be recorded with less than 5% significant differences in all compared signal characteristics metrics. Volunteers reported wearing comfort of 3.6 ± 1.5 and 4.0 ± 1.8 for the dry and 2.5 ± 1.0 and 3.0 ± 1.1 for the gel‐based cap prior and after the EEG recordings, respectively (scale 1–10). Wearing tests indicated that up to 3, 200 applications are possible for the dry electrodes. The 256‐channel HD‐EEG dry electrode cap overcomes the principal limitations of HD‐EEG regarding preparation complexity and allows rapid application by not medically trained persons, enabling new use cases for HD‐EEG. Abstract : We describe the design and validation of a novel 256‐channel high‐density electroencephalography (HD‐EEG) cap comprising dry electrodes made from polyurethane and coated with Ag/AgCl. We compare in a study with 30 volunteers the novel dry HD‐EEG cap to a conventional gel‐based cap for electrode‐skin impedances, resting state EEG, visual evoked potentials, applicability, and wear. The 256‐channel HD‐EEG dry electrode cap overcomes the principal limitations of HD‐EEG regarding preparation complexity and allows rapid application by not medically trained persons, enabling new use cases for HD‐EEG. … (more)
- Is Part Of:
- Human brain mapping. Volume 43:Issue 4(2022)
- Journal:
- Human brain mapping
- Issue:
- Volume 43:Issue 4(2022)
- Issue Display:
- Volume 43, Issue 4 (2022)
- Year:
- 2022
- Volume:
- 43
- Issue:
- 4
- Issue Sort Value:
- 2022-0043-0004-0000
- Page Start:
- 1295
- Page End:
- 1308
- Publication Date:
- 2021-11-19
- Subjects:
- biopotential electrode -- dry electrode -- EEG -- EMG -- mobile EEG -- wearable biomedical sensors
Brain mapping -- Periodicals
611.81 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1097-0193 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/hbm.25721 ↗
- Languages:
- English
- ISSNs:
- 1065-9471
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4336.031000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 26188.xml