Optimization of magnetization transfer contrast for EPI FLAIR brain imaging. Issue 5 (5th January 2022)
- Record Type:
- Journal Article
- Title:
- Optimization of magnetization transfer contrast for EPI FLAIR brain imaging. Issue 5 (5th January 2022)
- Main Title:
- Optimization of magnetization transfer contrast for EPI FLAIR brain imaging
- Authors:
- Demir, Serdest
Clifford, Bryan
Lo, Wei‐Ching
Tabari, Azadeh
Goncalves Filho, Augusto Lio M.
Lang, Min
Cauley, Stephen F.
Setsompop, Kawin
Bilgic, Berkin
Lev, Michael H.
Schaefer, Pamela W.
Rapalino, Otto
Huang, Susie Y.
Hilbert, Tom
Feiweier, Thorsten
Conklin, John - Abstract:
- Abstract: Purpose: To evaluate the impact of magnetization transfer (MT) on brain tissue contrast in turbo‐spin‐echo (TSE) and EPI fluid‐attenuated inversion recovery (FLAIR) images, and to optimize an MT‐prepared EPI FLAIR pulse sequence to match the tissue contrast of a clinical reference TSE FLAIR protocol. Methods: Five healthy volunteers underwent 3T brain MRI, including single slice TSE FLAIR, multi‐slice TSE FLAIR, EPI FLAIR without MT‐preparation, and MT‐prepared EPI FLAIR with variations of the MT‐preparation parameters, including number of preparation pulses, pulse amplitude, and resonance offset. Automated co‐registration and gray matter (GM) versus white matter (WM) segmentation was performed using a T1‐MPRAGE acquisition, and the GM versus WM signal intensity ratio (contrast ratio) was calculated for each FLAIR acquisition. Results: Without MT preparation, EPI FLAIR showed poor tissue contrast (contrast ratio = 0.98), as did single slice TSE FLAIR. Multi‐slice TSE FLAIR provided high tissue contrast (contrast ratio = 1.14). MT‐prepared EPI FLAIR closely approximated the contrast of the multi‐slice TSE FLAIR images for two combinations of the MT‐preparation parameters (contrast ratio = 1.14). Optimized MT‐prepared EPI FLAIR provided a 50% reduction in scan time compared to the reference TSE FLAIR acquisition. Conclusion: Optimized MT‐prepared EPI FLAIR provides comparable brain tissue contrast to the multi‐slice TSE FLAIR images used in clinical practice.
- Is Part Of:
- Magnetic resonance in medicine. Volume 87:Issue 5(2022)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 87:Issue 5(2022)
- Issue Display:
- Volume 87, Issue 5 (2022)
- Year:
- 2022
- Volume:
- 87
- Issue:
- 5
- Issue Sort Value:
- 2022-0087-0005-0000
- Page Start:
- 2380
- Page End:
- 2387
- Publication Date:
- 2022-01-05
- Subjects:
- contrast -- echo planar imaging -- FLAIR -- magnetization transfer
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.29141 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 26193.xml