Healthcare Provider Characteristics and Cardiopulmonary Resuscitation Quality During Infant Resuscitation: A Simulation Study. Issue 2 (1st April 2022)
- Record Type:
- Journal Article
- Title:
- Healthcare Provider Characteristics and Cardiopulmonary Resuscitation Quality During Infant Resuscitation: A Simulation Study. Issue 2 (1st April 2022)
- Main Title:
- Healthcare Provider Characteristics and Cardiopulmonary Resuscitation Quality During Infant Resuscitation
- Authors:
- Khattab, Mona
Frisell, Karin
MacKinnon, Ralph
Chang, Todd
Raymond, Tia
Lofton, Lydia
Tofil, Nancy
Forrester, Katherine
Gohel, Charmin
Aitken, Deborah
Scalzo, Anthony
Moore-Clingenpeel, Melissa
Auerbach, Marc - Abstract:
- Abstract : Introduction: Healthcare providers' anthropometric characteristics can adversely affect adult cardiopulmonary resuscitation (CPR) performance quality. However, their effects on infant CPR are unknown. We aimed to determine any relationships between healthcare provider characteristics (anthropomorphic, demographics, training, occupational data) and simulated infant CPR performance at multiple international sites. Our secondary aim was to examine provider's CPR performance degradation. Methods: Providers from 4 international hospitals performed 2 minutes of single-rescuer simulated infant CPR using 2015 American Heart Association Basic Life Support criteria with guidance from a real-time visual performance feedback device. Providers' characteristics were collected, and the simulator collected compression and ventilation data. Multivariate analyses examined the entire 2 minutes and performance degradation. Results: Data from 127 participants were analyzed. Although median values for all compression variables (depth, rate, lean) and ventilation volume were within guideline target ranges, when looking at individuals, only 52% chest compressions and 20% ventilations adhered to the American Heart Association guidelines. Age was found to be independently associated with ventilation volume (direct-relationship), and height was associated with chest compression lean (shorter participant-deeper lean). No significant differences were noted based on sex or body mass index.Abstract : Introduction: Healthcare providers' anthropometric characteristics can adversely affect adult cardiopulmonary resuscitation (CPR) performance quality. However, their effects on infant CPR are unknown. We aimed to determine any relationships between healthcare provider characteristics (anthropomorphic, demographics, training, occupational data) and simulated infant CPR performance at multiple international sites. Our secondary aim was to examine provider's CPR performance degradation. Methods: Providers from 4 international hospitals performed 2 minutes of single-rescuer simulated infant CPR using 2015 American Heart Association Basic Life Support criteria with guidance from a real-time visual performance feedback device. Providers' characteristics were collected, and the simulator collected compression and ventilation data. Multivariate analyses examined the entire 2 minutes and performance degradation. Results: Data from 127 participants were analyzed. Although median values for all compression variables (depth, rate, lean) and ventilation volume were within guideline target ranges, when looking at individuals, only 52% chest compressions and 20% ventilations adhered to the American Heart Association guidelines. Age was found to be independently associated with ventilation volume (direct-relationship), and height was associated with chest compression lean (shorter participant-deeper lean). No significant differences were noted based on sex or body mass index. Neonatal intensive care unit participants were noted to perform shallower chest compressions ( P < 0.001). Overall, there was minimal evidence of performance degradation over 2 minutes. Conclusions: Isolated provider characteristics were noted among a diverse cohort of healthcare providers that may affect the CPR quality on a simulated infant. Understanding the relationships between provider characteristics and CPR quality could inform future infant CPR guidelines customized for the provider and not just the patient. … (more)
- Is Part Of:
- Simulation in healthcare. Volume 17:Issue 2(2022)
- Journal:
- Simulation in healthcare
- Issue:
- Volume 17:Issue 2(2022)
- Issue Display:
- Volume 17, Issue 2 (2022)
- Year:
- 2022
- Volume:
- 17
- Issue:
- 2
- Issue Sort Value:
- 2022-0017-0002-0000
- Page Start:
- 88
- Page End:
- 95
- Publication Date:
- 2022-04-01
- Subjects:
- CPR quality -- neonatal CPR -- resuscitation
Simulated patients -- Periodicals
362.1 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&NEWS=n&PAGE=toc&D=ovft&AN=01253104-000000000-00000 ↗
http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&NEWS=n&PAGE=toc&D=ovft&AN=01266021-000000000-00000 ↗
http://journals.lww.com/simulationinhealthcare/pages/default.aspx ↗
http://www.simulationinhealthcare.com ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/SIH.0000000000000599 ↗
- Languages:
- English
- ISSNs:
- 1559-2332
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8285.164020
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 26180.xml