Automatic segmentation of high‐risk clinical target volume for tandem‐and‐ovoids brachytherapy patients using an asymmetric dual‐path convolutional neural network. Issue 3 (4th February 2022)
- Record Type:
- Journal Article
- Title:
- Automatic segmentation of high‐risk clinical target volume for tandem‐and‐ovoids brachytherapy patients using an asymmetric dual‐path convolutional neural network. Issue 3 (4th February 2022)
- Main Title:
- Automatic segmentation of high‐risk clinical target volume for tandem‐and‐ovoids brachytherapy patients using an asymmetric dual‐path convolutional neural network
- Authors:
- Cao, Yufeng
Vassantachart, April
Ragab, Omar
Bian, Shelly
Mitra, Priya
Xu, Zhengzheng
Gallogly, Audrey Zhuang
Cui, Jing
Shen, Zhilei Liu
Balik, Salim
Gribble, Michael
Chang, Eric L.
Fan, Zhaoyang
Yang, Wensha - Abstract:
- Abstract: Purposes: Preimplant diagnostic magnetic resonance imaging is the gold standard for image‐guided tandem‐and‐ovoids (T&O) brachytherapy for cervical cancer. However, high dose rate brachytherapy planning is typically done on postimplant CT‐based high‐risk clinical target volume (HR‐CTVCT ) because the transfer of preimplant Magnetic resonance (MR)‐based HR‐CTV (HR‐CTVMR ) to the postimplant planning CT is difficult due to anatomical changes caused by applicator insertion, vaginal packing, and the filling status of the bladder and rectum. This study aims to train a dual‐path convolutional neural network (CNN) for automatic segmentation of HR‐CTVCT on postimplant planning CT with guidance from preimplant diagnostic MR. Methods: Preimplant T2‐weighted MR and postimplant CT images for 65 (48 for training, eight for validation, and nine for testing) patients were retrospectively solicited from our institutional database. MR was aligned to the corresponding CT using rigid registration. HR‐CTVCT and HR‐CTVMR were manually contoured on CT and MR by an experienced radiation oncologist. All images were then resampled to a spatial resolution of 0.5 × 0.5 × 1.25 mm. A dual‐path 3D asymmetric CNN architecture with two encoding paths was built to extract CT and MR image features. The MR was masked by HR‐CTVMR contour while the entire CT volume was included. The network put an asymmetric weighting of 18:6 for CT: MR. Voxel‐based dice similarity coefficient (DSCV ), sensitivity,Abstract: Purposes: Preimplant diagnostic magnetic resonance imaging is the gold standard for image‐guided tandem‐and‐ovoids (T&O) brachytherapy for cervical cancer. However, high dose rate brachytherapy planning is typically done on postimplant CT‐based high‐risk clinical target volume (HR‐CTVCT ) because the transfer of preimplant Magnetic resonance (MR)‐based HR‐CTV (HR‐CTVMR ) to the postimplant planning CT is difficult due to anatomical changes caused by applicator insertion, vaginal packing, and the filling status of the bladder and rectum. This study aims to train a dual‐path convolutional neural network (CNN) for automatic segmentation of HR‐CTVCT on postimplant planning CT with guidance from preimplant diagnostic MR. Methods: Preimplant T2‐weighted MR and postimplant CT images for 65 (48 for training, eight for validation, and nine for testing) patients were retrospectively solicited from our institutional database. MR was aligned to the corresponding CT using rigid registration. HR‐CTVCT and HR‐CTVMR were manually contoured on CT and MR by an experienced radiation oncologist. All images were then resampled to a spatial resolution of 0.5 × 0.5 × 1.25 mm. A dual‐path 3D asymmetric CNN architecture with two encoding paths was built to extract CT and MR image features. The MR was masked by HR‐CTVMR contour while the entire CT volume was included. The network put an asymmetric weighting of 18:6 for CT: MR. Voxel‐based dice similarity coefficient (DSCV ), sensitivity, precision, and 95% Hausdorff distance (95‐HD) were used to evaluate model performance. Cross‐validation was performed to assess model stability. The study cohort was divided into a small tumor group (<20 cc), medium tumor group (20–40 cc), and large tumor group (>40 cc) based on the HR‐CTVCT for model evaluation. Single‐path CNN models were trained with the same parameters as those in dual‐path models. Results: For this patient cohort, the dual‐path CNN model improved each of our objective findings, including DSCV, sensitivity, and precision, with an average improvement of 8%, 7%, and 12%, respectively. The 95‐HD was improved by an average of 1.65 mm compared to the single‐path model with only CT images as input. In addition, the area under the curve for different networks was 0.86 (dual‐path with CT and MR) and 0.80 (single‐path with CT), respectively. The dual‐path CNN model with asymmetric weighting achieved the best performance with DSCV of 0.65 ± 0.03 (0.61–0.70), 0.79 ± 0.02 (0.74–0.85), and 0.75 ± 0.04 (0.68–0.79) for small, medium, and large group. 95‐HD were 7.34 (5.35–10.45) mm, 5.48 (3.21–8.43) mm, and 6.21 (5.34–9.32) mm for the three size groups, respectively. Conclusions: An asymmetric CNN model with two encoding paths from preimplant MR (masked by HR‐CTVMR ) and postimplant CT images was successfully developed for automatic segmentation of HR‐CTVCT for T&O brachytherapy patients. … (more)
- Is Part Of:
- Medical physics. Volume 49:Issue 3(2022)
- Journal:
- Medical physics
- Issue:
- Volume 49:Issue 3(2022)
- Issue Display:
- Volume 49, Issue 3 (2022)
- Year:
- 2022
- Volume:
- 49
- Issue:
- 3
- Issue Sort Value:
- 2022-0049-0003-0000
- Page Start:
- 1712
- Page End:
- 1722
- Publication Date:
- 2022-02-04
- Subjects:
- CNN -- Deep learning -- HDR -- high‐risk CTV -- segmentation -- Tandem and Ovoids
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1002/mp.15490 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 26174.xml