A novel algorithm to assess the quality of 12-lead ECG recordings: validation in a real telecardiology application. (1st March 2023)
- Record Type:
- Journal Article
- Title:
- A novel algorithm to assess the quality of 12-lead ECG recordings: validation in a real telecardiology application. (1st March 2023)
- Main Title:
- A novel algorithm to assess the quality of 12-lead ECG recordings: validation in a real telecardiology application
- Authors:
- de Moraes, Jermana L
Paixão, Gabriela M M
Gomes, Paulo R
Mendes, Eduardo M A M
Ribeiro, Antônio Luiz P
Beda, Alessandro - Abstract:
- Abstract: Objective . Automatic detection of Electrocardiograms (ECG) quality is fundamental to minimize costs and risks related to delayed diagnosis due to low ECG quality. Most algorithms to assess ECG quality include non-intuitive parameters. Also, they were developed using data non-representative of a real-world scenario, in terms of pathological ECGs and overrepresentation of low-quality ECG. Therefore, we introduce an algorithm to assess 12-lead ECG quality, Noise Automatic Classification Algorithm (NACA) developed in Telehealth Network of Minas Gerais (TNMG). Approach . NACA estimates a signal-to-noise ratio (SNR) for each ECG lead, where 'signal' is an estimated heartbeat template, and 'noise' is the discrepancy between the template and the ECG heartbeat. Then, clinically-inspired rules based on SNR are used to classify the ECG as acceptable or unacceptable. NACA was compared with Quality Measurement Algorithm (QMA), the winner of Computing in Cardiology Challenge 2011 (ChallengeCinC) by using five metrics: sensitivity (Se), specificity (Sp), positive predictive value (PPV), F 2, and cost reduction resulting from adoption of the algorithm. Two datasets were used for validation: TestTNMG, consisting of 34 310 ECGs received by TNMG (1% unacceptable and 50% pathological); ChallengeCinC, consisting of 1000 ECGs (23% unacceptable, higher than real-world scenario). Main results . Both algorithms reached a similar performance on ChallengeCinC, although NACA performedAbstract: Objective . Automatic detection of Electrocardiograms (ECG) quality is fundamental to minimize costs and risks related to delayed diagnosis due to low ECG quality. Most algorithms to assess ECG quality include non-intuitive parameters. Also, they were developed using data non-representative of a real-world scenario, in terms of pathological ECGs and overrepresentation of low-quality ECG. Therefore, we introduce an algorithm to assess 12-lead ECG quality, Noise Automatic Classification Algorithm (NACA) developed in Telehealth Network of Minas Gerais (TNMG). Approach . NACA estimates a signal-to-noise ratio (SNR) for each ECG lead, where 'signal' is an estimated heartbeat template, and 'noise' is the discrepancy between the template and the ECG heartbeat. Then, clinically-inspired rules based on SNR are used to classify the ECG as acceptable or unacceptable. NACA was compared with Quality Measurement Algorithm (QMA), the winner of Computing in Cardiology Challenge 2011 (ChallengeCinC) by using five metrics: sensitivity (Se), specificity (Sp), positive predictive value (PPV), F 2, and cost reduction resulting from adoption of the algorithm. Two datasets were used for validation: TestTNMG, consisting of 34 310 ECGs received by TNMG (1% unacceptable and 50% pathological); ChallengeCinC, consisting of 1000 ECGs (23% unacceptable, higher than real-world scenario). Main results . Both algorithms reached a similar performance on ChallengeCinC, although NACA performed considerably better than QMA in TestTNMG (Se = 0.89 versus 0.21; Sp = 0.99 versus 0.98; PPV = 0.59 versus 0.08; F 2 = 0.76 versus 0.16 and cost reduction 2.3 ± 1.8% versus 0.3 ± 0.3%, respectively). Significance . Implementing of NACA in a telecardiology service results in evident health and financial benefits for the patients and the healthcare system. … (more)
- Is Part Of:
- Physiological measurement. Volume 44:Number 3(2023)
- Journal:
- Physiological measurement
- Issue:
- Volume 44:Number 3(2023)
- Issue Display:
- Volume 44, Issue 3 (2023)
- Year:
- 2023
- Volume:
- 44
- Issue:
- 3
- Issue Sort Value:
- 2023-0044-0003-0000
- Page Start:
- Page End:
- Publication Date:
- 2023-03-01
- Subjects:
- electrocardiogram -- beat template -- signal quality assessment -- class imbalance -- real-world application
Physiology -- Measurement -- Periodicals
Patient monitoring -- Periodicals
612 - Journal URLs:
- http://ioppublishing.org/ ↗
http://iopscience.iop.org/0967-3334 ↗ - DOI:
- 10.1088/1361-6579/acbc09 ↗
- Languages:
- English
- ISSNs:
- 0967-3334
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 26177.xml