Deformability of ascending thoracic aorta aneurysms assessed using ultrafast ultrasound and a principal strain estimator: In vitro evaluation and in vivo feasibility. Issue 3 (28th January 2022)
- Record Type:
- Journal Article
- Title:
- Deformability of ascending thoracic aorta aneurysms assessed using ultrafast ultrasound and a principal strain estimator: In vitro evaluation and in vivo feasibility. Issue 3 (28th January 2022)
- Main Title:
- Deformability of ascending thoracic aorta aneurysms assessed using ultrafast ultrasound and a principal strain estimator: In vitro evaluation and in vivo feasibility
- Authors:
- Wang, Diya
Chayer, Boris
Destrempes, François
Gesnik, Marc
Tournoux, François
Cloutier, Guy - Abstract:
- Abstract: Background: Noninvasive vascular strain imaging under conventional line‐by‐line scanning has a low frame rate and lateral resolution and depends on the coordinate system. It is thus affected by high deformations due to image decorrelation between frames. Purpose: To develop an ultrafast time‐ensemble regularized tissue‐Doppler optical‐flow principal strain estimator for aorta deformability assessment in a long‐axis view. Methods: This approach alleviated the impact of lateral resolution using image compounding and that of the coordinate system dependency using principal strain. Accuracy and feasibility were evaluated in two aorta‐mimicking phantoms first, and then in four age‐matched individuals with either a normal aorta or a pathological ascending thoracic aorta aneurysm (TAA). Results: Instantaneous aortic maximum and minimum principal strain maps and regional accumulated strains during each cardiac cycle were estimated at systolic and diastolic phases to characterize the normal aorta and TAA. In vitro, principal strain results matched sonomicrometry measurements. In vivo, a significant decrease in maximum and minimum principal strains was observed in TAA cases, whose range was respectively 7.9 ± 6.4% and 8.2 ± 2.6% smaller than in normal aortas. Conclusions: The proposed principal strain estimator showed an ability to potentially assess TAA deformability, which may provide an individualized and reliable evaluation method for TAA rupture risk assessment.
- Is Part Of:
- Medical physics. Volume 49:Issue 3(2022)
- Journal:
- Medical physics
- Issue:
- Volume 49:Issue 3(2022)
- Issue Display:
- Volume 49, Issue 3 (2022)
- Year:
- 2022
- Volume:
- 49
- Issue:
- 3
- Issue Sort Value:
- 2022-0049-0003-0000
- Page Start:
- 1759
- Page End:
- 1775
- Publication Date:
- 2022-01-28
- Subjects:
- aorta deformability -- principal strain -- ultrafast imaging
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1002/mp.15464 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 26174.xml