Does Cardiac Catheterization Facilitate Hemodynamic Optimization of Pediatric Patients on Continuous-Flow Ventricular Assist Devices?. Issue 4 (7th July 2021)
- Record Type:
- Journal Article
- Title:
- Does Cardiac Catheterization Facilitate Hemodynamic Optimization of Pediatric Patients on Continuous-Flow Ventricular Assist Devices?. Issue 4 (7th July 2021)
- Main Title:
- Does Cardiac Catheterization Facilitate Hemodynamic Optimization of Pediatric Patients on Continuous-Flow Ventricular Assist Devices?
- Authors:
- Lahiri, Subhrajit
Choudhry, Swati
Denfield, Susan W.
Price, Jack F.
Cabrera, Antonio G.
Dreyer, William J.
Spinner, Joseph A.
Loar, Robert W.
Elias, Barb
McMullen, Jason
Qureshi, Athar M.
Adachi, Iki
Tunuguntla, Hari Priya - Abstract:
- Abstract : Understanding optimal ventricular assist device (VAD) parameters for pediatric patients is valuable given the inherent issue of patient-device size mismatch and heterogeneous cardiac anatomy in children. We evaluated our center's experience of continuous-flow VAD (CF-VAD) optimization using cardiac catheterization. We performed a retrospective analysis of all patients on CF-VAD support who underwent hemodynamic heart catheterization from 2013 to 2018. Fifteen patients had 16 hemodynamic catheterizations performed. The indications for hemodynamic optimization by catheterization included clinical signs of heart failure while on CF-VAD (9 of 16, 56%), pretransplant evaluation of pulmonary hypertension (2 of 16, 13%), or assessment of myocardial recovery (5 of 16, 31%). The median age at catheterization was 12 years (interquartile range: 8–16). Median baseline speed of device was 2333 ± 253 rotations per minute. The goal was to find the speed at which optimal hemodynamics were achieved, defined by low wedge pressure with an acceptable central venous pressure. Of the 16 catheterizations, there were 9 (56%) speed increases to achieve optimal hemodynamics and 5 (33%) speed decreases for hemodynamic optimization or for potential explant. The speed was not changed in 2 (13%) catheterizations as the patients were determined to be at an optimal hemodynamic state. Overall, VAD settings were optimized in 75% (14 of 16) of hemodynamic catheterizations. There were no adverseAbstract : Understanding optimal ventricular assist device (VAD) parameters for pediatric patients is valuable given the inherent issue of patient-device size mismatch and heterogeneous cardiac anatomy in children. We evaluated our center's experience of continuous-flow VAD (CF-VAD) optimization using cardiac catheterization. We performed a retrospective analysis of all patients on CF-VAD support who underwent hemodynamic heart catheterization from 2013 to 2018. Fifteen patients had 16 hemodynamic catheterizations performed. The indications for hemodynamic optimization by catheterization included clinical signs of heart failure while on CF-VAD (9 of 16, 56%), pretransplant evaluation of pulmonary hypertension (2 of 16, 13%), or assessment of myocardial recovery (5 of 16, 31%). The median age at catheterization was 12 years (interquartile range: 8–16). Median baseline speed of device was 2333 ± 253 rotations per minute. The goal was to find the speed at which optimal hemodynamics were achieved, defined by low wedge pressure with an acceptable central venous pressure. Of the 16 catheterizations, there were 9 (56%) speed increases to achieve optimal hemodynamics and 5 (33%) speed decreases for hemodynamic optimization or for potential explant. The speed was not changed in 2 (13%) catheterizations as the patients were determined to be at an optimal hemodynamic state. Overall, VAD settings were optimized in 75% (14 of 16) of hemodynamic catheterizations. There were no adverse events related to catheterization. Thus, we conclude that catheterization-based hemodynamic assessment is safe and effective for optimizing VAD speed and provides guidance on medical management in children supported on CF-VAD. … (more)
- Is Part Of:
- ASAIO journal. Volume 68:Issue 4(2022)
- Journal:
- ASAIO journal
- Issue:
- Volume 68:Issue 4(2022)
- Issue Display:
- Volume 68, Issue 4 (2022)
- Year:
- 2022
- Volume:
- 68
- Issue:
- 4
- Issue Sort Value:
- 2022-0068-0004-0000
- Page Start:
- 584
- Page End:
- 591
- Publication Date:
- 2021-07-07
- Subjects:
- VAD -- pediatric -- optimization -- hemodynamic -- speed -- RAMP
Artificial organs -- Periodicals
617 - Journal URLs:
- http://journals.lww.com/asaiojournal/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/MAT.0000000000001504 ↗
- Languages:
- English
- ISSNs:
- 1058-2916
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1738.840500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 26155.xml