Development of a plan complexity mitigation algorithm based on gamma passing rate predictions for volumetric‐modulated arc therapy. Issue 3 (28th January 2022)
- Record Type:
- Journal Article
- Title:
- Development of a plan complexity mitigation algorithm based on gamma passing rate predictions for volumetric‐modulated arc therapy. Issue 3 (28th January 2022)
- Main Title:
- Development of a plan complexity mitigation algorithm based on gamma passing rate predictions for volumetric‐modulated arc therapy
- Authors:
- Ono, Tomohiro
Nakamura, Mitsuhiro
Ono, Yuka
Nakamura, Kiyonao
Mizowaki, Takashi - Abstract:
- Abstract: Background and purpose: Volumetric‐modulated arc therapy (VMAT) is a complex rotational therapy technique in which highly conformal dose distribution can be realized by varying the speed of gantry rotation, multileaf collimator (MLC) shape, and dose rate. However, the complexity of the technique creates a discrepancy between the calculated and measured doses. Thus, to mitigate the plan complexity in VMAT, this study aimed to develop an algorithm and evaluate its usefulness by conducting a feasibility study. Materials and methods: A total of 50 patients who underwent VMAT between September 2015 and December 2020 were arbitrarily selected for this study. Specifically, patients with less than 85% gamma passing rate (GPR) at 5%/1 mm or 3%/2 mm criterion were selected randomly. Using the GPR prediction model, problematic MLC positions that contribute to a decrease in GPR were identified. Those problematic MLC positions were optimized using a limited nonlinear algorithm under mechanical limitations. Additionally, the dose prescription for the target was re‐normalized. The VMAT modulated complexity score (MCSv ), averaged aperture area (AA), and monitor unit per gray (MU/Gy) were evaluated as plan complexity parameters. Calculated doses in patient geometry were evaluated for the target and its surrounding region. In addition, an ArcCHECK cylindrical diode array was used to measure the dose, and GPRs at 5%/1 mm and 3%/2 mm criteria were evaluated to analyze the differenceAbstract: Background and purpose: Volumetric‐modulated arc therapy (VMAT) is a complex rotational therapy technique in which highly conformal dose distribution can be realized by varying the speed of gantry rotation, multileaf collimator (MLC) shape, and dose rate. However, the complexity of the technique creates a discrepancy between the calculated and measured doses. Thus, to mitigate the plan complexity in VMAT, this study aimed to develop an algorithm and evaluate its usefulness by conducting a feasibility study. Materials and methods: A total of 50 patients who underwent VMAT between September 2015 and December 2020 were arbitrarily selected for this study. Specifically, patients with less than 85% gamma passing rate (GPR) at 5%/1 mm or 3%/2 mm criterion were selected randomly. Using the GPR prediction model, problematic MLC positions that contribute to a decrease in GPR were identified. Those problematic MLC positions were optimized using a limited nonlinear algorithm under mechanical limitations. Additionally, the dose prescription for the target was re‐normalized. The VMAT modulated complexity score (MCSv ), averaged aperture area (AA), and monitor unit per gray (MU/Gy) were evaluated as plan complexity parameters. Calculated doses in patient geometry were evaluated for the target and its surrounding region. In addition, an ArcCHECK cylindrical diode array was used to measure the dose, and GPRs at 5%/1 mm and 3%/2 mm criteria were evaluated to analyze the difference between the mitigated and original plans. The difference was calculated using the mean ± standard deviation. Results: The differences between the MCSv, AA, and MU/cGy values for the mitigated and original plans were 0.8 ± 1.7 (×10 –2 ), 42.7 ± 57.9, and ‐5.6 ± 8.5, respectively. Regarding the calculated dose, the dose volume parameters were consistent within 1% for the target and the surrounding region. The differences between the mitigated and original plans were 1.8 ± 2.9% and 1.3 ± 1.8% for GPRs at 5%/1 mm and 3%/2 mm, respectively. Conclusions: This feasibility study resulted in the development of an algorithm with the potential to mitigate plan complexity and improve the GPR for VMAT under minor leaf position modifications. … (more)
- Is Part Of:
- Medical physics. Volume 49:Issue 3(2022)
- Journal:
- Medical physics
- Issue:
- Volume 49:Issue 3(2022)
- Issue Display:
- Volume 49, Issue 3 (2022)
- Year:
- 2022
- Volume:
- 49
- Issue:
- 3
- Issue Sort Value:
- 2022-0049-0003-0000
- Page Start:
- 1793
- Page End:
- 1802
- Publication Date:
- 2022-01-28
- Subjects:
- gamma passing rate -- plan complexity -- prediction model -- quality assurance -- volumetric‐modulated arc therapy
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1002/mp.15466 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 26156.xml