Hand-held dynamometry for assessment of muscle strength in patients with inflammatory myopathies. (7th October 2020)
- Record Type:
- Journal Article
- Title:
- Hand-held dynamometry for assessment of muscle strength in patients with inflammatory myopathies. (7th October 2020)
- Main Title:
- Hand-held dynamometry for assessment of muscle strength in patients with inflammatory myopathies
- Authors:
- Saygin, Didem
Oddis, Chester V
Moghadam-Kia, Siamak
Rockette-Wagner, Bonny
Neiman, Nicole
Koontz, Diane
Aggarwal, Rohit - Abstract:
- Abstract: Objectives: Muscle weakness in idiopathic inflammatory myopathies (IIMs) is conventionally assessed using manual muscle testing (MMT). However, more objective tools must be developed to accurately and reliably quantify muscle strength in myositis patients. Hand-held dynamometry (HHD) is a quantitative, portable device with reported reliability in neuromuscular disorders. Our aim was to assess the reliability, validity and responsiveness of HHD in myositis. Methods: Myositis patients [DM, necrotizing myopathy (NM), PM and anti-synthetase syndrome] evaluated at the University of Pittsburgh myositis centre were prospectively enrolled. Each patient was assessed at 0, 3 and 6 months for validated outcome measures of myositis disease activity and physical function. At each visit, muscle strength was assessed using both MMT and HHD (Micro FET2, Hoggan Health Industries, Draper, UT, USA). The reliability, validity and responsiveness of the HHD was assessed using standard statistical methods. Results: Fifty IIM patients (60% female; mean age 51.6 years; 6 PM, 9 NM, 24 DM and 11 anti-synthetase syndrome) were enrolled. HHD showed strong test–retest intrarater reliability ( r = 0.96) and interrater reliability ( r = 0.98). HHD correlated significantly with the MMT score ( r = 0.48, P = 0.0006) and myositis disease activity and functional measures. Longitudinal analysis showed a significant and strong association between the HHD and MMT as well as 2016 ACR/EULAR myositisAbstract: Objectives: Muscle weakness in idiopathic inflammatory myopathies (IIMs) is conventionally assessed using manual muscle testing (MMT). However, more objective tools must be developed to accurately and reliably quantify muscle strength in myositis patients. Hand-held dynamometry (HHD) is a quantitative, portable device with reported reliability in neuromuscular disorders. Our aim was to assess the reliability, validity and responsiveness of HHD in myositis. Methods: Myositis patients [DM, necrotizing myopathy (NM), PM and anti-synthetase syndrome] evaluated at the University of Pittsburgh myositis centre were prospectively enrolled. Each patient was assessed at 0, 3 and 6 months for validated outcome measures of myositis disease activity and physical function. At each visit, muscle strength was assessed using both MMT and HHD (Micro FET2, Hoggan Health Industries, Draper, UT, USA). The reliability, validity and responsiveness of the HHD was assessed using standard statistical methods. Results: Fifty IIM patients (60% female; mean age 51.6 years; 6 PM, 9 NM, 24 DM and 11 anti-synthetase syndrome) were enrolled. HHD showed strong test–retest intrarater reliability ( r = 0.96) and interrater reliability ( r = 0.98). HHD correlated significantly with the MMT score ( r = 0.48, P = 0.0006) and myositis disease activity and functional measures. Longitudinal analysis showed a significant and strong association between the HHD and MMT as well as 2016 ACR/EULAR myositis response criteria ( r = 0.8, P < 0.0001) demonstrating responsiveness. The mean effect size and standardized response mean of HHD was large: 0.95 and 1.03, respectively. MMT had a high ceiling effect compared with HHD. Conclusion: HHD demonstrated strong reliability, construct validity and responsiveness in myositis patients. External validation studies are required to confirm these findings. … (more)
- Is Part Of:
- Rheumatology. Volume 60:Number 5(2021)
- Journal:
- Rheumatology
- Issue:
- Volume 60:Number 5(2021)
- Issue Display:
- Volume 60, Issue 5 (2021)
- Year:
- 2021
- Volume:
- 60
- Issue:
- 5
- Issue Sort Value:
- 2021-0060-0005-0000
- Page Start:
- 2146
- Page End:
- 2156
- Publication Date:
- 2020-10-07
- Subjects:
- hand-held dynamometry -- myositis -- inflammatory myopathy -- muscle strength -- outcome measure
Rheumatism -- Periodicals
Rheumatology -- Periodicals
616.723005 - Journal URLs:
- http://rheumatology.oupjournals.org ↗
http://rheumatology.oxfordjournals.org ↗
http://ukcatalogue.oup.com/ ↗
http://firstsearch.oclc.org ↗ - DOI:
- 10.1093/rheumatology/keaa419 ↗
- Languages:
- English
- ISSNs:
- 1462-0324
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7960.731900
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 26133.xml