The influence of the fire temperature on the condition of steel roof structure. (April 2023)
- Record Type:
- Journal Article
- Title:
- The influence of the fire temperature on the condition of steel roof structure. (April 2023)
- Main Title:
- The influence of the fire temperature on the condition of steel roof structure
- Authors:
- Mackiewicz, M.
Krentowski, J.R.
Knyziak, P.
Kowalski, R. - Abstract:
- Highlights: Assessment of structure damages caused by accidental fire load is a complex process. Determining temperature range decides of reusing the structural elements after repair. Assumption of the fire scenario and temperature range is crucial. Decisions of reusing undamaged components should be justified by in-depth analysis. Designing and reconstruction of facilities should take into account fire protection. Abstract: Contemporary process of structure designing takes into account the requirements for the structural load-bearing capacity, parameters in terms of serviceability, as well as safety and resistance in the case of fire occurrence. The fire protection required by law does not guarantee full resistance, but only the safety of the integrity of the structure subjected to fire over a certain period of time. Structures after a fire are assessed in terms of their further use. A special case is the partial damage to the structure of some load-bearing elements, including their separate elements. The research issue is the assessment of the structure both as a whole and as individual components. Usually some elements have to be replaced and some can be used directly or after strengthening. This issue has been discussed in the article. Fire in the sports hall building developed as a result of improper use of the ventilation system. The range and effects of fire affected some of the structural elements. An assessment of the fire consequences was carried out, numericalHighlights: Assessment of structure damages caused by accidental fire load is a complex process. Determining temperature range decides of reusing the structural elements after repair. Assumption of the fire scenario and temperature range is crucial. Decisions of reusing undamaged components should be justified by in-depth analysis. Designing and reconstruction of facilities should take into account fire protection. Abstract: Contemporary process of structure designing takes into account the requirements for the structural load-bearing capacity, parameters in terms of serviceability, as well as safety and resistance in the case of fire occurrence. The fire protection required by law does not guarantee full resistance, but only the safety of the integrity of the structure subjected to fire over a certain period of time. Structures after a fire are assessed in terms of their further use. A special case is the partial damage to the structure of some load-bearing elements, including their separate elements. The research issue is the assessment of the structure both as a whole and as individual components. Usually some elements have to be replaced and some can be used directly or after strengthening. This issue has been discussed in the article. Fire in the sports hall building developed as a result of improper use of the ventilation system. The range and effects of fire affected some of the structural elements. An assessment of the fire consequences was carried out, numerical analyzes were performed and the results were compared with accurate measurements of the structure deformation. The obtained conclusions allowed to determine the impact of the fire on the structural elements and the procedure for the repair of the damaged facility. Some elements, mainly the roof covering, had to be replaced, and the main elements of the structure were strengthened to ensure the required level of safety. … (more)
- Is Part Of:
- Engineering failure analysis. Volume 146(2023)
- Journal:
- Engineering failure analysis
- Issue:
- Volume 146(2023)
- Issue Display:
- Volume 146, Issue 2023 (2023)
- Year:
- 2023
- Volume:
- 146
- Issue:
- 2023
- Issue Sort Value:
- 2023-0146-2023-0000
- Page Start:
- Page End:
- Publication Date:
- 2023-04
- Subjects:
- Accidental temperature load -- Fire -- Steel roof structure -- Damage -- Failure -- Strengthening
System failures (Engineering) -- Periodicals
Fracture mechanics -- Periodicals
Reliability (Engineering) -- Periodicals
Pannes -- Périodiques
Rupture, Mécanique de la -- Périodiques
Fiabilité -- Périodiques
Fracture mechanics
Reliability (Engineering)
System failures (Engineering)
Periodicals
Electronic journals
620.112 - Journal URLs:
- http://www.sciencedirect.com/science/journal/13506307 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.engfailanal.2023.107080 ↗
- Languages:
- English
- ISSNs:
- 1350-6307
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3760.991000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 26146.xml