New technique and application of truncated CBCT processing in adaptive radiotherapy for breast cancer. (April 2023)
- Record Type:
- Journal Article
- Title:
- New technique and application of truncated CBCT processing in adaptive radiotherapy for breast cancer. (April 2023)
- Main Title:
- New technique and application of truncated CBCT processing in adaptive radiotherapy for breast cancer
- Authors:
- Xie, Kai
Gao, Liugang
Xi, Qianyi
Zhang, Heng
Zhang, Sai
Zhang, Fan
Sun, Jiawei
Lin, Tao
Sui, Jianfeng
Ni, Xinye - Abstract:
- Highlights: Propose a CycleGAN-based network to synthesize sCT from low-dose truncated low-dose cone beam computed tomography (CBCT). The content loss was added to the loss function to make the anatomical structure of sCT close to CBCT. Truncated CBCT simulated by complete thoracic CBCT was used for training and then applied to breast cancer patients. Abstract: Objective: A generative adversarial network (TCBCTNet) was proposed to generate synthetic computed tomography (sCT) from truncated low-dose cone-beam computed tomography (CBCT) and planning CT (pCT). The sCT was applied to the dose calculation of radiotherapy for patients with breast cancer. Methods: The low-dose CBCT and pCT images of 80 female thoracic patients were used for training. The CBCT, pCT, and replanning CT (rCT) images of 20 thoracic patients and 20 patients with breast cancer were used for testing. All patients were fixed in the same posture with a vacuum pad. The CBCT images were scanned under the Fast Chest M20 protocol with a 50% reduction in projection frames compared with the standard Chest M20 protocol. Rigid registration was performed between pCT and CBCT, and deformation registration was performed between rCT and CBCT. In the training stage of the TCBCTNet, truncated CBCT images obtained from complete CBCT images by simulation were used. The input of the CBCT→CT generator was truncated CBCT and pCT, and TCBCTNet was applied to patients with breast cancer after training. The accuracy of the sCTHighlights: Propose a CycleGAN-based network to synthesize sCT from low-dose truncated low-dose cone beam computed tomography (CBCT). The content loss was added to the loss function to make the anatomical structure of sCT close to CBCT. Truncated CBCT simulated by complete thoracic CBCT was used for training and then applied to breast cancer patients. Abstract: Objective: A generative adversarial network (TCBCTNet) was proposed to generate synthetic computed tomography (sCT) from truncated low-dose cone-beam computed tomography (CBCT) and planning CT (pCT). The sCT was applied to the dose calculation of radiotherapy for patients with breast cancer. Methods: The low-dose CBCT and pCT images of 80 female thoracic patients were used for training. The CBCT, pCT, and replanning CT (rCT) images of 20 thoracic patients and 20 patients with breast cancer were used for testing. All patients were fixed in the same posture with a vacuum pad. The CBCT images were scanned under the Fast Chest M20 protocol with a 50% reduction in projection frames compared with the standard Chest M20 protocol. Rigid registration was performed between pCT and CBCT, and deformation registration was performed between rCT and CBCT. In the training stage of the TCBCTNet, truncated CBCT images obtained from complete CBCT images by simulation were used. The input of the CBCT→CT generator was truncated CBCT and pCT, and TCBCTNet was applied to patients with breast cancer after training. The accuracy of the sCT was evaluated by anatomy and dosimetry and compared with the generative adversarial network with UNet and ResNet as the generators (named as UnetGAN, ResGAN). Results: The three models could improve the image quality of CBCT and reduce the scattering artifacts while preserving the anatomical geometry of CBCT. For the chest test set, TCBCTNet achieved the best mean absolute error (MAE, 21.18±3.76 HU), better than 23.06±3.90 HU in UnetGAN and 22.47±3.57 HU in ResGAN. When applied to patients with breast cancer, TCBCTNet performance decreased, and MAE was 25.34±6.09 HU. Compared with rCT, sCT by TCBCTNet showed consistent dose distribution and subtle absolute dose differences between the target and the organ at risk. The 3D gamma pass rates were 98.98%±0.64% and 99.69%±0.22% at 2 mm/2% and 3 mm/3%, respectively. Ablation experiments confirmed that pCT and content loss played important roles in TCBCTNet. Conclusions: High-quality sCT images could be synthesized from truncated low-dose CBCT and pCT by using the proposed TCBCTNet model. In addition, sCT could be used to accurately calculate the dose distribution for patients with breast cancer. … (more)
- Is Part Of:
- Computer methods and programs in biomedicine. Volume 231(2023)
- Journal:
- Computer methods and programs in biomedicine
- Issue:
- Volume 231(2023)
- Issue Display:
- Volume 231, Issue 2023 (2023)
- Year:
- 2023
- Volume:
- 231
- Issue:
- 2023
- Issue Sort Value:
- 2023-0231-2023-0000
- Page Start:
- Page End:
- Publication Date:
- 2023-04
- Subjects:
- Truncated low-dose CBCT -- Synthesized CT -- Unsupervised deep learning -- Breast cancer radiotherapy
Medicine -- Computer programs -- Periodicals
Biology -- Computer programs -- Periodicals
Computers -- Periodicals
Medicine -- Periodicals
Médecine -- Logiciels -- Périodiques
Biologie -- Logiciels -- Périodiques
Biology -- Computer programs
Medicine -- Computer programs
Periodicals
Electronic journals
610.28 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01692607 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.cmpb.2023.107393 ↗
- Languages:
- English
- ISSNs:
- 0169-2607
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3394.095000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 26140.xml