NCCT-CECT image synthesizers and their application to pulmonary vessel segmentation. (April 2023)
- Record Type:
- Journal Article
- Title:
- NCCT-CECT image synthesizers and their application to pulmonary vessel segmentation. (April 2023)
- Main Title:
- NCCT-CECT image synthesizers and their application to pulmonary vessel segmentation
- Authors:
- Pang, Haowen
Qi, Shouliang
Wu, Yanan
Wang, Meihuan
Li, Chen
Sun, Yu
Qian, Wei
Tang, Guoyan
Xu, Jiaxuan
Liang, Zhenyu
Chen, Rongchang - Abstract:
- Highlights: Two synthesizers are proposed for the mutual synthesis between NCCT and CECT. Self-supervised learning and dual-energy CT are used to pretrain the synthesizers. The synthesizers outperformed state-of-the-art methods. The proposed synthesizers can help segment pulmonary vessels from NCCT images. Abstract: Background and objectives: Non-contrast CT (NCCT) and contrast-enhanced CT (CECT) are important diagnostic tools with distinct features and applications for chest diseases. We developed two synthesizers for the mutual synthesis of NCCT and CECT and evaluated their applications. Methods: Two synthesizers (S1 and S2 ) were proposed based on a generative adversarial network. S1 generated synthetic CECT (SynCECT) from NCCT and S2 generated synthetic NCCT (SynNCCT) from CECT. A new training procedure for synthesizers was proposed. Initially, the synthesizers were pretrained using self-supervised learning (SSL) and dual-energy CT (DECT) and then fine-tuned using the registered NCCT and CECT images. Pulmonary vessel segmentation from NCCT was used as an example to demonstrate the effectiveness of the synthesizers. Two strategies (ST1 and ST2 ) were proposed for pulmonary vessel segmentation. In ST1, CECT images were used to train a segmentation model (Model-CECT), NCCT images were converted to SynCECT through S1, and SynCECT was input to Model-CECT for testing. In ST2, CECT data were converted to SynNCCT through S2 . SynNCCT and CECT-based annotations were used to trainHighlights: Two synthesizers are proposed for the mutual synthesis between NCCT and CECT. Self-supervised learning and dual-energy CT are used to pretrain the synthesizers. The synthesizers outperformed state-of-the-art methods. The proposed synthesizers can help segment pulmonary vessels from NCCT images. Abstract: Background and objectives: Non-contrast CT (NCCT) and contrast-enhanced CT (CECT) are important diagnostic tools with distinct features and applications for chest diseases. We developed two synthesizers for the mutual synthesis of NCCT and CECT and evaluated their applications. Methods: Two synthesizers (S1 and S2 ) were proposed based on a generative adversarial network. S1 generated synthetic CECT (SynCECT) from NCCT and S2 generated synthetic NCCT (SynNCCT) from CECT. A new training procedure for synthesizers was proposed. Initially, the synthesizers were pretrained using self-supervised learning (SSL) and dual-energy CT (DECT) and then fine-tuned using the registered NCCT and CECT images. Pulmonary vessel segmentation from NCCT was used as an example to demonstrate the effectiveness of the synthesizers. Two strategies (ST1 and ST2 ) were proposed for pulmonary vessel segmentation. In ST1, CECT images were used to train a segmentation model (Model-CECT), NCCT images were converted to SynCECT through S1, and SynCECT was input to Model-CECT for testing. In ST2, CECT data were converted to SynNCCT through S2 . SynNCCT and CECT-based annotations were used to train an additional model (Model-NCCT), and NCCT was input to Model-NCCT for testing. Three datasets, D1 (40 paired CTs), D2 (14 NCCTs and 14 CECTs), and D3 (49 paired DECTs), were used to evaluate the synthesizers and strategies. Results: For S1, the mean absolute error (MAE), mean squared error (MSE), peak signal-to-noise ratio (PSNR), and structural similarity index (SSIM) were 14.60± 2.19, 1644± 890, 34.34± 1.91, and 0.94± 0.02, respectively. For S2, they were 12.52± 2.59, 1460± 922, 35.08± 2.35, and 0.95± 0.02, respectively. Our synthesizers outperformed the counterparts of CycleGAN, Pix2Pix, and Pix2PixHD. The results of ablation studies on SSL pretraining, DECT pretraining, and fine-tuning showed that performance worsened (for example, for S1, MAE increased to 16.53± 3.10, 17.98± 3.10, and 20.57± 3.75, respectively). Model-NCCT and Model-CECT achieved dice similarity coefficients (DSC) of 0.77 and 0.86 on D1 and 0.77 and 0.72 on D2, respectively. Conclusions: The proposed synthesizers realized mutual and high-quality synthesis between NCCT and CECT images; the training procedures, including SSL pretraining, DECT pretraining, and fine-tuning, were critical to their effectiveness. The results demonstrated the usefulness of synthesizers for pulmonary vessel segmentation from NCCT images. … (more)
- Is Part Of:
- Computer methods and programs in biomedicine. Volume 231(2023)
- Journal:
- Computer methods and programs in biomedicine
- Issue:
- Volume 231(2023)
- Issue Display:
- Volume 231, Issue 2023 (2023)
- Year:
- 2023
- Volume:
- 231
- Issue:
- 2023
- Issue Sort Value:
- 2023-0231-2023-0000
- Page Start:
- Page End:
- Publication Date:
- 2023-04
- Subjects:
- Medical image synthesis -- Generative adversarial network -- Computed tomography -- Pulmonary vessel segmentation
Medicine -- Computer programs -- Periodicals
Biology -- Computer programs -- Periodicals
Computers -- Periodicals
Medicine -- Periodicals
Médecine -- Logiciels -- Périodiques
Biologie -- Logiciels -- Périodiques
Biology -- Computer programs
Medicine -- Computer programs
Periodicals
Electronic journals
610.28 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01692607 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.cmpb.2023.107389 ↗
- Languages:
- English
- ISSNs:
- 0169-2607
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3394.095000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 26140.xml