Electro‐immunosensor for ultra‐sensitive determination of cardiac troponin I based on reduced graphene oxide and polytyramine. Issue 2 (24th November 2022)
- Record Type:
- Journal Article
- Title:
- Electro‐immunosensor for ultra‐sensitive determination of cardiac troponin I based on reduced graphene oxide and polytyramine. Issue 2 (24th November 2022)
- Main Title:
- Electro‐immunosensor for ultra‐sensitive determination of cardiac troponin I based on reduced graphene oxide and polytyramine
- Authors:
- Brussasco, Jéssica G.
Guedes, Pedro H. G.
Moço, Anna C. R.
Moraes, Dayane D.
Flauzino, José M. R.
Silva, Heliane S.
Silva, Atair C.
Silva, Jonathan P.
Madurro, João M.
Brito‐Madurro, Ana G. - Abstract:
- Abstract: This work reports the construction of a novel nanostructured immunosensor for detection of the troponin I biomarker (cTnI). Anti‐troponin I antibody was anchored on the modified graphite electrode with reduced graphene oxide and polytyramine for detection of troponin I in serum samples. The performance of the electro‐immunosensor was evaluated by differential pulse voltammetry. The immunosensor presented a wide work range, from 4 ng mL −1 to 4 pg mL −1, whose detection limit (4 pg mL −1 ) is significantly lower than the basal level in human serum, and maintained 100% of response after 30 days of storage. Moreover, the immunosensor showed good selectivity for detection of cTnI in real sample containing interfering substances and specificity of response to cTnI in the serum of healthy and sick patients, and demonstrated the possibility of reuse for two consecutive analyses, in addition to using a simplified and inexpensive platform when compared to other devices, demonstrating them excellent potential for application in diagnosis in the early stages of acute myocardial infarction. Abstract : Scheme of construction steps of the immunosensor where a platform containing GE/rGO/pTyr/anti‐cTnI/cTnI is indirectly detected using differential pulse voltammetry.
- Is Part Of:
- Journal of molecular recognition. Volume 36:Issue 2(2023)
- Journal:
- Journal of molecular recognition
- Issue:
- Volume 36:Issue 2(2023)
- Issue Display:
- Volume 36, Issue 2 (2023)
- Year:
- 2023
- Volume:
- 36
- Issue:
- 2
- Issue Sort Value:
- 2023-0036-0002-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2022-11-24
- Subjects:
- acute myocardial infarction -- bioelectrode -- biosensor -- cardiac troponin I -- nanocomposite -- polytyramine -- reduced graphene oxide
Molecular recognition -- Periodicals
Models, Molecular -- Periodicals
Molecular Conformation -- Periodicals
Molecular Sequence Data -- Periodicals
Molecular Structure -- Periodicals
Carrier Proteins -- Periodicals
572.8 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/jmr.2995 ↗
- Languages:
- English
- ISSNs:
- 0952-3499
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5020.725000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 26129.xml