Energy, exergy, economic and environmental analysis of a running integrated anaerobic digester-combined heat and power system in a municipal wastewater treatment plant. (November 2022)
- Record Type:
- Journal Article
- Title:
- Energy, exergy, economic and environmental analysis of a running integrated anaerobic digester-combined heat and power system in a municipal wastewater treatment plant. (November 2022)
- Main Title:
- Energy, exergy, economic and environmental analysis of a running integrated anaerobic digester-combined heat and power system in a municipal wastewater treatment plant
- Authors:
- Sanaye, Sepehr
Yazdani, Mohsen - Abstract:
- Abstract: 4E (energy, exergy, economic, and environmental) analysis of a municipal wastewater treatment plant (WWTP) including an integrated system with anaerobic digesters and combined heat and power units (AD-CHP) is performed here. This type of analysis was required for AD-CHP system at Tehran WWTP to estimate the plant energy/exergy efficiency, to estimate annual profit and payback period, as well as to study these parameters with change in plant operating conditions. This necessary type of analysis was not found in literature and in previous studies. The results showed that the integrated system generated 4.6 MW el, net and 2.1 MW th, net with 3100 m 3 /day of total mixture of primary and secondary sludge (4.5% total solids and 81.2% volatile solids fraction). In this regard, the system energy efficiency was 24.3%. The flow exergy values throughout the plant were also estimated and demonstrated in two Sankey and Grassmann diagrams which showed the plant overall exergy efficiency of 17.3%. The integrated system also reduced CO2 emissions by 64% compared to that for a traditional energy supply system (buying electricity from the grid and producing hot water by burning biogas produced from anaerobic digesters). In economic analysis, a selling incentive scenario employed in which generated electricity was sold to the grid at price of 0.125 $/kWh while the price of electricity purchased was 0.081 $/kWh. The payback period was 2.4 years in this case which was significantlyAbstract: 4E (energy, exergy, economic, and environmental) analysis of a municipal wastewater treatment plant (WWTP) including an integrated system with anaerobic digesters and combined heat and power units (AD-CHP) is performed here. This type of analysis was required for AD-CHP system at Tehran WWTP to estimate the plant energy/exergy efficiency, to estimate annual profit and payback period, as well as to study these parameters with change in plant operating conditions. This necessary type of analysis was not found in literature and in previous studies. The results showed that the integrated system generated 4.6 MW el, net and 2.1 MW th, net with 3100 m 3 /day of total mixture of primary and secondary sludge (4.5% total solids and 81.2% volatile solids fraction). In this regard, the system energy efficiency was 24.3%. The flow exergy values throughout the plant were also estimated and demonstrated in two Sankey and Grassmann diagrams which showed the plant overall exergy efficiency of 17.3%. The integrated system also reduced CO2 emissions by 64% compared to that for a traditional energy supply system (buying electricity from the grid and producing hot water by burning biogas produced from anaerobic digesters). In economic analysis, a selling incentive scenario employed in which generated electricity was sold to the grid at price of 0.125 $/kWh while the price of electricity purchased was 0.081 $/kWh. The payback period was 2.4 years in this case which was significantly lower (57%) than that for the case with no-selling electricity to the grid (5.6 years). Moreover, the levelized cost of electricity (LCOE, which is the minimum selling price of electricity required by the integrated system or the point at which cost and revenue are equal) was 127 $/MWh, which was within the acceptable range reported by the International Renewable Energy Agency for the biomass-power generation technologies. Highlights: Comprehensive 4E analysis of a running sludge-fed anaerobic digestion plant was performed. Integrated system generated 4.6 MWel and 2.1 MWth power to meet Tehran WWTP needs. Energy and exergy efficiency values of the system were 24.3% and 17.3% respectively. Relative payback period was 2.4 years for selling scenario with emission cost. Levelized cost of electricity was found to be 127 $/MWh. … (more)
- Is Part Of:
- Energy reports. Volume 8(2022)
- Journal:
- Energy reports
- Issue:
- Volume 8(2022)
- Issue Display:
- Volume 8, Issue 2022 (2022)
- Year:
- 2022
- Volume:
- 8
- Issue:
- 2022
- Issue Sort Value:
- 2022-0008-2022-0000
- Page Start:
- 9724
- Page End:
- 9741
- Publication Date:
- 2022-11
- Subjects:
- Thermo-economic analysis -- Environmental analysis -- Wastewater treatment plant -- Anaerobic digestion -- Combined heat and power
Power resources -- Periodicals
Energy industries -- Periodicals
Power resources
Periodicals
Electronic journals
621.04205 - Journal URLs:
- http://www.sciencedirect.com/science/journal/23524847/ ↗
http://www.sciencedirect.com/ ↗ - DOI:
- 10.1016/j.egyr.2022.07.155 ↗
- Languages:
- English
- ISSNs:
- 2352-4847
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 26107.xml