Kidney absorbed radiation doses for [177Lu]Lu-PSMA-617 and [177Lu]Lu-PSMA-I&T determined by 3D clinical dosimetry. Issue 4 (4th April 2023)
- Record Type:
- Journal Article
- Title:
- Kidney absorbed radiation doses for [177Lu]Lu-PSMA-617 and [177Lu]Lu-PSMA-I&T determined by 3D clinical dosimetry. Issue 4 (4th April 2023)
- Main Title:
- Kidney absorbed radiation doses for [177Lu]Lu-PSMA-617 and [177Lu]Lu-PSMA-I&T determined by 3D clinical dosimetry
- Authors:
- Uijen, Maike J.M.
Privé, Bastiaan M.
van Herpen, Carla M.L.
Westdorp, Harm
van Gemert, Willemijn A.
de Bakker, Maarten
Gotthardt, Martin
Konijnenberg, Mark W.
Peters, Steffie M.B.
Nagarajah, James - Abstract:
- Abstract : Purpose: For prostate-specific membrane antigen-directed radioligand therapy (PSMA-RLT), [ 177 Lu]Lu-PSMA-617 and [ 177 Lu]Lu-PSMA-I&T are the currently preferred compounds. Recent preclinical studies suggested ~30x higher kidney absorbed dose for [ 177 Lu]Lu-PSMA-I&T compared to [ 177 Lu]Lu-PSMA-617, which may lead to an increased risk of kidney toxicity. We performed two single-centre, prospective dosimetry studies with either [ 177 Lu]Lu-PSMA-617 or [ 177 Lu]Lu-PSMA-I&T, using an identical dosimetry protocol. We evaluated the absorbed doses of both 177 Lu-labelled radioligands in human kidneys. Methods: 3D SPECT/computed tomography (CT) imaging of the kidneys was performed after PSMA-RLT in cancer patients with PSMA-positive disease and an adequate glomerular filtration rate (≥50 mL/min). Ten metastatic hormone-sensitive prostate cancer patients (mHSPC) were treated with [ 177 Lu]Lu-PSMA-617 and 10 advanced salivary gland cancer (SGC) patients were treated with [ 177 Lu]Lu-PSMA-I&T. SPECT/CT imaging was performed at five timepoints (1 h, 24 h, 48 h, 72 h, and 168 h post-injection). In mHSPC patients, SPECT/CT imaging was performed after cycles 1 and 2 (cumulative activity: 9 GBq) and in SGC patients only after cycle 1 (activity: 7.4 GBq). Kidney absorbed dose was calculated using organ-based dosimetry. Results: The median kidney absorbed dose was 0.49 Gy/GBq (range: 0.34–0.66) and 0.73 Gy/GBq (range: 0.42–1.31) for [ 177 Lu]Lu-PSMA-617 and [ 177 Lu]Lu-PSMA-I&T,Abstract : Purpose: For prostate-specific membrane antigen-directed radioligand therapy (PSMA-RLT), [ 177 Lu]Lu-PSMA-617 and [ 177 Lu]Lu-PSMA-I&T are the currently preferred compounds. Recent preclinical studies suggested ~30x higher kidney absorbed dose for [ 177 Lu]Lu-PSMA-I&T compared to [ 177 Lu]Lu-PSMA-617, which may lead to an increased risk of kidney toxicity. We performed two single-centre, prospective dosimetry studies with either [ 177 Lu]Lu-PSMA-617 or [ 177 Lu]Lu-PSMA-I&T, using an identical dosimetry protocol. We evaluated the absorbed doses of both 177 Lu-labelled radioligands in human kidneys. Methods: 3D SPECT/computed tomography (CT) imaging of the kidneys was performed after PSMA-RLT in cancer patients with PSMA-positive disease and an adequate glomerular filtration rate (≥50 mL/min). Ten metastatic hormone-sensitive prostate cancer patients (mHSPC) were treated with [ 177 Lu]Lu-PSMA-617 and 10 advanced salivary gland cancer (SGC) patients were treated with [ 177 Lu]Lu-PSMA-I&T. SPECT/CT imaging was performed at five timepoints (1 h, 24 h, 48 h, 72 h, and 168 h post-injection). In mHSPC patients, SPECT/CT imaging was performed after cycles 1 and 2 (cumulative activity: 9 GBq) and in SGC patients only after cycle 1 (activity: 7.4 GBq). Kidney absorbed dose was calculated using organ-based dosimetry. Results: The median kidney absorbed dose was 0.49 Gy/GBq (range: 0.34–0.66) and 0.73 Gy/GBq (range: 0.42–1.31) for [ 177 Lu]Lu-PSMA-617 and [ 177 Lu]Lu-PSMA-I&T, respectively (independent samples t test; P = 0.010). Conclusion: This study shows that the kidney absorbed dose for [ 177 Lu]Lu-PSMA-617 and [ 177 Lu]Lu-PSMA-I&T differs, with a ~1.5x higher median kidney absorbed dose for [ 177 Lu]Lu-PSMA-I&T. This difference in the clinical setting is considerably smaller than observed in preclinical studies and may not hamper treatments with [ 177 Lu]Lu-PSMA-I&T. … (more)
- Is Part Of:
- Nuclear medicine communications. Volume 44:Issue 4(2023)
- Journal:
- Nuclear medicine communications
- Issue:
- Volume 44:Issue 4(2023)
- Issue Display:
- Volume 44, Issue 4 (2023)
- Year:
- 2023
- Volume:
- 44
- Issue:
- 4
- Issue Sort Value:
- 2023-0044-0004-0000
- Page Start:
- 270
- Page End:
- 275
- Publication Date:
- 2023-04-04
- Subjects:
- dosimetry -- [177Lu]Lu-PSMA -- prostate-specific membrane antigen (PSMA) -- radioligand therapy -- SPECT imaging
Nuclear medicine -- Periodicals
616.07575 - Journal URLs:
- http://journals.lww.com/nuclearmedicinecomm/pages/default.aspx ↗
http://journals.lww.com/pages/default.aspx ↗
http://www.lww.com/Product/0143-3636 ↗ - DOI:
- 10.1097/MNM.0000000000001658 ↗
- Languages:
- English
- ISSNs:
- 0143-3636
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6180.923000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 26095.xml