An evaluation of mechanical and biophysical skin parameters at different body locations. Issue 2 (17th February 2023)
- Record Type:
- Journal Article
- Title:
- An evaluation of mechanical and biophysical skin parameters at different body locations. Issue 2 (17th February 2023)
- Main Title:
- An evaluation of mechanical and biophysical skin parameters at different body locations
- Authors:
- John, Anto J. U. K.
Galdo, Francesco Del
Gush, Rodney
Worsley, Peter R. - Abstract:
- Abstract: Background: Skin is the largest organ in the body, representing an important interface to monitor health and disease. However, there is significant variation in skin properties for different ages, genders and body regions due to the differences in the structure and morphology of the skin tissues. This study aimed to evaluate the use of non‐invasive tools to discriminate a range of mechanical and functional skin parameters from different skin sites. Materials and methods: A cohort of 15 healthy volunteers was recruited following appropriate informed consent. Four well‐established CE‐marked non‐invasive techniques were used to measure four anatomical regions: palm, forearm, sole and lower lumbar L3, using a repeated measures design. Skin parameters included trans‐epidermal water loss (TEWL), pH (acidity), erythema, stratum corneum hydration and stiffness and elasticity using Myoton Pro (skin and muscle probe). Differences between body locations for each parameter and the intra‐rater reliability between days were evaluated by the same operator. Results: The results indicate that parameters differed significantly between skin sites. For the Myoton skin probe, the sole recorded the highest stiffness value of 1006 N/m (SD ± 179), while the lower lumbar recorded the least value of 484 N/m (SD ± 160). The muscle indenter Myoton probe revealed the palm's highest value of 754 N/m (± 108), and the lower lumbar recorded the least value of 208 N/m (SD ± 44). TEWL values wereAbstract: Background: Skin is the largest organ in the body, representing an important interface to monitor health and disease. However, there is significant variation in skin properties for different ages, genders and body regions due to the differences in the structure and morphology of the skin tissues. This study aimed to evaluate the use of non‐invasive tools to discriminate a range of mechanical and functional skin parameters from different skin sites. Materials and methods: A cohort of 15 healthy volunteers was recruited following appropriate informed consent. Four well‐established CE‐marked non‐invasive techniques were used to measure four anatomical regions: palm, forearm, sole and lower lumbar L3, using a repeated measures design. Skin parameters included trans‐epidermal water loss (TEWL), pH (acidity), erythema, stratum corneum hydration and stiffness and elasticity using Myoton Pro (skin and muscle probe). Differences between body locations for each parameter and the intra‐rater reliability between days were evaluated by the same operator. Results: The results indicate that parameters differed significantly between skin sites. For the Myoton skin probe, the sole recorded the highest stiffness value of 1006 N/m (SD ± 179), while the lower lumbar recorded the least value of 484 N/m (SD ± 160). The muscle indenter Myoton probe revealed the palm's highest value of 754 N/m (± 108), and the lower lumbar recorded the least value of 208 N/m (SD ± 44). TEWL values were lowest on the forearm, averaging 11 g/m2/h, and highest on the palm, averaging 41 g/m2/h. Similar skin hydration levels were recorded in three of the four sites, with the main difference being observed in the sole averaging 13 arbitrary units. Erythema values were characterised by a high degree of inter‐subject variation, and no significant differences between sites or sides were observed. The Myoton Pro Skin showed excellent reliability (intra‐class correlation coefficients > 0.70) for all sites with exception of one site right lower back; the Myoton pro muscle probes showed good to poor reliability (0.90–017), the corneometer showed excellent reliability (>0.75) among all the sites tested, and the TEWL showed Good to poor reliability (0.74–0.4) among sites. Conclusion: The study revealed that using non‐invasive methods, the biophysical properties of skin can be mapped, and significant differences in the mechanical and functional properties of skin were observed. These parameters were reliably recorded between days, providing a basis for their use in assessing and monitoring changes in the skin during health and disease. … (more)
- Is Part Of:
- Skin research and technology. Volume 29:Issue 2(2023)
- Journal:
- Skin research and technology
- Issue:
- Volume 29:Issue 2(2023)
- Issue Display:
- Volume 29, Issue 2 (2023)
- Year:
- 2023
- Volume:
- 29
- Issue:
- 2
- Issue Sort Value:
- 2023-0029-0002-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2023-02-17
- Subjects:
- biophysical parameters -- functional properties -- hydration -- mechanical loading -- mechanical properties -- sensitivity analysis
Skin -- Research -- Periodicals
Skin -- Diseases -- Periodicals
Skin -- Physiology -- Periodicals
616.5 - Journal URLs:
- http://www.blackwellpublishing.com/journal.asp?ref=0909-752X&site=1 ↗
http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1600-0846 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/srt.13292 ↗
- Languages:
- English
- ISSNs:
- 0909-752X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8295.948000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 26062.xml