Time- and Dose-Dependent Effects of Hyaluronidase on the Degradation of Different Hyaluronan-Based Fillers In Vitro. Issue 3 (22nd November 2022)
- Record Type:
- Journal Article
- Title:
- Time- and Dose-Dependent Effects of Hyaluronidase on the Degradation of Different Hyaluronan-Based Fillers In Vitro. Issue 3 (22nd November 2022)
- Main Title:
- Time- and Dose-Dependent Effects of Hyaluronidase on the Degradation of Different Hyaluronan-Based Fillers In Vitro
- Authors:
- Gerber, Peter Arne
Buhren, Bettina A.
Bölke, Edwin
Philipp-Dormston, Wolfgang G.
Homey, Bernhard
Schrumpf, Holger - Abstract:
- Abstract : Background: Hyaluronidase (HYAL) is regarded as the standard for the management of complications associated with hyaluronan (HA)-based fillers. Therefore, the understanding of interactions of HA fillers and HYAL is essential. Methods: Nine different commercially available HA fillers (Belotero, Juvéderm, and Restylane) with varying degrees of cross-linking were used for the analysis. Fluorescently dyed HA fillers were individually incubated with varying doses of HYAL [bovine HYAL (Hylase "Dessau"; Riemser Pharma, Germany); 5, 10, and 20 U/mL] or sodium chloride and monitored by time-lapse microscopy. HA filler degradation was assessed as a decrease in fluorescence intensity of HA filler plus HYAL compared to HA filler plus control, quantified by computerized image analysis. Results: HA fillers show significant differences in their reaction to HYAL. Levels of degradation of HA fillers are positively correlated with increasing concentrations of HYAL. At the highest concentration of HYAL (20 U/mL), all fillers except one (Belotero Volume) reached a significant level of degradation at 5 to 9 hours. Conclusions: In this study, the authors show that most HA fillers can be dissolved by HYAL in a dose- and time-dependent manner. Of note, the fillers' technology and degree of cross-linking seem to exert stronger effects on the degradability by HYAL as compared to the concentration of HA. Clinical Relevance Statement: The authors' in vitro analyses support clinicalAbstract : Background: Hyaluronidase (HYAL) is regarded as the standard for the management of complications associated with hyaluronan (HA)-based fillers. Therefore, the understanding of interactions of HA fillers and HYAL is essential. Methods: Nine different commercially available HA fillers (Belotero, Juvéderm, and Restylane) with varying degrees of cross-linking were used for the analysis. Fluorescently dyed HA fillers were individually incubated with varying doses of HYAL [bovine HYAL (Hylase "Dessau"; Riemser Pharma, Germany); 5, 10, and 20 U/mL] or sodium chloride and monitored by time-lapse microscopy. HA filler degradation was assessed as a decrease in fluorescence intensity of HA filler plus HYAL compared to HA filler plus control, quantified by computerized image analysis. Results: HA fillers show significant differences in their reaction to HYAL. Levels of degradation of HA fillers are positively correlated with increasing concentrations of HYAL. At the highest concentration of HYAL (20 U/mL), all fillers except one (Belotero Volume) reached a significant level of degradation at 5 to 9 hours. Conclusions: In this study, the authors show that most HA fillers can be dissolved by HYAL in a dose- and time-dependent manner. Of note, the fillers' technology and degree of cross-linking seem to exert stronger effects on the degradability by HYAL as compared to the concentration of HA. Clinical Relevance Statement: The authors' in vitro analyses support clinical recommendations stating that in the case of a vascular filler incident, HYAL should be applied early and at significant doses ("Time is skin!"). CLINICAL QUESTION/LEVEL OF EVIDENCE: Therapeutic, V. … (more)
- Is Part Of:
- Plastic and reconstructive surgery. Volume 151:Issue 3(2023)
- Journal:
- Plastic and reconstructive surgery
- Issue:
- Volume 151:Issue 3(2023)
- Issue Display:
- Volume 151, Issue 3 (2023)
- Year:
- 2023
- Volume:
- 151
- Issue:
- 3
- Issue Sort Value:
- 2023-0151-0003-0000
- Page Start:
- 560
- Page End:
- 567
- Publication Date:
- 2022-11-22
- Subjects:
- Surgery, Plastic -- Periodicals
617.95205 - Journal URLs:
- http://journals.lww.com ↗
- DOI:
- 10.1097/PRS.0000000000009916 ↗
- Languages:
- English
- ISSNs:
- 0032-1052
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6528.924000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 26037.xml