Evaluating the Differences Between Fluorescein Tear Break-up Time and Noninvasive Measurement Techniques. Issue 3 (20th March 2023)
- Record Type:
- Journal Article
- Title:
- Evaluating the Differences Between Fluorescein Tear Break-up Time and Noninvasive Measurement Techniques. Issue 3 (20th March 2023)
- Main Title:
- Evaluating the Differences Between Fluorescein Tear Break-up Time and Noninvasive Measurement Techniques
- Authors:
- Itokawa, Takashi
Suzuki, Takashi
Koh, Shizuka
Hori, Yuichi - Abstract:
- Abstract : Objectives: To compare fluorescein tear break-up time (BUT) and noninvasive BUT measured using interferometry and corneal topography. Methods: We investigated 34 eyes of 34 patients with dry eye (mean age 39.2±8.3 years) and 16 eyes of 16 non–dry eye subjects (33.5±6.5 years). Tear film stability was measured using fluorescein BUT, noninvasive BUT (NIBUT)-DR1 with an interferometer, and noninvasive keratographic BUT (NIKBUT)-first and average using corneal topography. Correlations between fluorescein BUT and noninvasive BUT parameters were determined statistically. The noninvasive BUTs were compared between the dry eye and non–dry eye groups. The agreement between fluorescein and noninvasive BUTs was described using Bland–Altman analysis. Results: Fluorescein BUT was significantly correlated with NIBUT-DR1, NIKBUT-first, and NIKBUT-average. The Bland–Altman analysis revealed bias and 95% limits of agreement between fluorescein BUT and noninvasive BUTs as follows: NIBUT-DR1: 2.07 s, −5.33 to 9.46 s; NIKBUT-first: 3.39 s, −5.46 to 12.24 s; NIKBUT-average: 6.61 s, −1.58 to 14.79 s. The noninvasive BUTs were significantly different between the two groups. When NIBUT-DR1, NIKBUT-first, and NIKBUT-average with Bland–Altman correction were used as an index for dry eye, the cut-off values were 7.1, 8.4, and 11.6 s, respectively. The sensitivities were 0.735, 0.818, and 0.727 and specificities were 0.500, 0.437, and 0.562, respectively. Conclusion: Fluorescein BUT andAbstract : Objectives: To compare fluorescein tear break-up time (BUT) and noninvasive BUT measured using interferometry and corneal topography. Methods: We investigated 34 eyes of 34 patients with dry eye (mean age 39.2±8.3 years) and 16 eyes of 16 non–dry eye subjects (33.5±6.5 years). Tear film stability was measured using fluorescein BUT, noninvasive BUT (NIBUT)-DR1 with an interferometer, and noninvasive keratographic BUT (NIKBUT)-first and average using corneal topography. Correlations between fluorescein BUT and noninvasive BUT parameters were determined statistically. The noninvasive BUTs were compared between the dry eye and non–dry eye groups. The agreement between fluorescein and noninvasive BUTs was described using Bland–Altman analysis. Results: Fluorescein BUT was significantly correlated with NIBUT-DR1, NIKBUT-first, and NIKBUT-average. The Bland–Altman analysis revealed bias and 95% limits of agreement between fluorescein BUT and noninvasive BUTs as follows: NIBUT-DR1: 2.07 s, −5.33 to 9.46 s; NIKBUT-first: 3.39 s, −5.46 to 12.24 s; NIKBUT-average: 6.61 s, −1.58 to 14.79 s. The noninvasive BUTs were significantly different between the two groups. When NIBUT-DR1, NIKBUT-first, and NIKBUT-average with Bland–Altman correction were used as an index for dry eye, the cut-off values were 7.1, 8.4, and 11.6 s, respectively. The sensitivities were 0.735, 0.818, and 0.727 and specificities were 0.500, 0.437, and 0.562, respectively. Conclusion: Fluorescein BUT and noninvasive BUTs were significantly correlated, and noninvasive BUTs had higher values than fluorescein BUT. Considering the differences between fluorescein BUT and noninvasive BUTs, noninvasive methods can be used as effective tool for diagnosing dry eye. … (more)
- Is Part Of:
- Eye & contact lens. Volume 49:Issue 3(2023)
- Journal:
- Eye & contact lens
- Issue:
- Volume 49:Issue 3(2023)
- Issue Display:
- Volume 49, Issue 3 (2023)
- Year:
- 2023
- Volume:
- 49
- Issue:
- 3
- Issue Sort Value:
- 2023-0049-0003-0000
- Page Start:
- 104
- Page End:
- 109
- Publication Date:
- 2023-03-20
- Subjects:
- Dry eye -- Noninvasive tear break-up time -- Tear break-up time
Contact lenses -- Periodicals
Intraocular lenses -- Periodicals
Orthokeratology -- Periodicals
Anterior segment (Eye) -- Diseases -- Periodicals
617.7523 - Journal URLs:
- http://journals.lww.com/claojournal/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/ICL.0000000000000966 ↗
- Languages:
- English
- ISSNs:
- 1542-2321
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3854.587000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 26050.xml