159 The Need Of Six Monthly Follow Up X-Rays Post Total Knee Replacement(TKR). (12th October 2021)
- Record Type:
- Journal Article
- Title:
- 159 The Need Of Six Monthly Follow Up X-Rays Post Total Knee Replacement(TKR). (12th October 2021)
- Main Title:
- 159 The Need Of Six Monthly Follow Up X-Rays Post Total Knee Replacement(TKR)
- Authors:
- Baig, N
Ferrari, M
Lukaszewicz, A - Abstract:
- Abstract: Background: There is a longstanding culture of repeat x-rays after total knee replacement (TKR) as part of follow up, often combined with a clinic review. This is to check that the prosthesis is in a satisfactory position. There are inherently a number of issues with this historic approach including exposure of patients to further radiation who may be asymptomatic, time delays in busy clinics or x-ray departments and costs. Objectives: The aim of this audit was to assess whether follow up plain films after TKR are methodically undertaken and of benefit to confirm satisfactory appearance if immediate post -operative x-rays were unremarkable. The findings of a six month follow up x-ray was specifically evaluated. The secondary aim was to establish the timing of further follow up x-rays within the department. Method: 200 patients were included within the analysis, they all received a TKR at a major trauma centre, over a one-year period between December 2017 and December 2018. Results: It was found that 100% of those patients having a post-operative film had a satisfactory appearance. 78% of patients had at least one further follow op x-ray of which 99.4% were satisfactory. Up to five follow up x-rays were taken with 53.5% of patients having a follow up x-ray at 6 months. Conclusions: From the above results there is minimal, if any, evidence within the data set to support routine, additional follow up imaging if initial post-operative films are satisfactory, and theAbstract: Background: There is a longstanding culture of repeat x-rays after total knee replacement (TKR) as part of follow up, often combined with a clinic review. This is to check that the prosthesis is in a satisfactory position. There are inherently a number of issues with this historic approach including exposure of patients to further radiation who may be asymptomatic, time delays in busy clinics or x-ray departments and costs. Objectives: The aim of this audit was to assess whether follow up plain films after TKR are methodically undertaken and of benefit to confirm satisfactory appearance if immediate post -operative x-rays were unremarkable. The findings of a six month follow up x-ray was specifically evaluated. The secondary aim was to establish the timing of further follow up x-rays within the department. Method: 200 patients were included within the analysis, they all received a TKR at a major trauma centre, over a one-year period between December 2017 and December 2018. Results: It was found that 100% of those patients having a post-operative film had a satisfactory appearance. 78% of patients had at least one further follow op x-ray of which 99.4% were satisfactory. Up to five follow up x-rays were taken with 53.5% of patients having a follow up x-ray at 6 months. Conclusions: From the above results there is minimal, if any, evidence within the data set to support routine, additional follow up imaging if initial post-operative films are satisfactory, and the patient is asymptomatic. … (more)
- Is Part Of:
- British journal of surgery. Volume 108:Supplement 6(2021)
- Journal:
- British journal of surgery
- Issue:
- Volume 108:Supplement 6(2021)
- Issue Display:
- Volume 108, Issue 6 (2021)
- Year:
- 2021
- Volume:
- 108
- Issue:
- 6
- Issue Sort Value:
- 2021-0108-0006-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-10-12
- Subjects:
- Surgery -- Periodicals
617.005 - Journal URLs:
- http://www.bjs.co.uk/bjsCda/cda/microHome.do ↗
https://academic.oup.com/bjs# ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1093/bjs/znab259.972 ↗
- Languages:
- English
- ISSNs:
- 0007-1323
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2325.000000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 26032.xml