Development and Detection Experiment of Scanning Stage for High-throughput Gene Sequencer. Issue 1 (1st March 2023)
- Record Type:
- Journal Article
- Title:
- Development and Detection Experiment of Scanning Stage for High-throughput Gene Sequencer. Issue 1 (1st March 2023)
- Main Title:
- Development and Detection Experiment of Scanning Stage for High-throughput Gene Sequencer
- Authors:
- Zhao, Yanyan
Cao, Yue
Tan, Wenjun
Yang, Tianshi
Chen, Hao - Abstract:
- Abstract: In order to meet the requirements of large stroke, high precision, and high acceleration step scanning imaging of the worktable of a high-throughput gene sequencer, a mechanical ultra-precision positioning platform is designed. The XY translation table has a significant impact on the fluxes and accuracy of gene sequencing detection. Using the finite element method to analyze the structural modal and obtain the first-order natural frequency; Then using the vibration test system and laser interferometer to test the first-order natural frequency and the repeat positioning accuracy of the XY translation table. The test results show that the first-order natural frequencies of the platform in X, y and Z directions are 175Hz, 111Hz and 191Hz respectively, which is much higher than the upper-frequency limit of 16.7Hz step scanning servo bandwidth. The two-way repeat positioning accuracy of XY translation table are ± 0.462 µ m and ± 0.429 µ m, meet ± 0.6 µm. So the scanning stage can meet the index requirements of a high-throughput gene sequencers under the specified working conditions, and the measured test data combined with the modal analysis model can provide a research basis for the optimal design of the subsequent platform.
- Is Part Of:
- Journal of physics. Volume 2449:Issue 1(2023)
- Journal:
- Journal of physics
- Issue:
- Volume 2449:Issue 1(2023)
- Issue Display:
- Volume 2449, Issue 1 (2023)
- Year:
- 2023
- Volume:
- 2449
- Issue:
- 1
- Issue Sort Value:
- 2023-2449-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2023-03-01
- Subjects:
- Gene Sequencer -- Ultra Precision Positioning Platform -- Natural Frequency -- Repeat Positioning Accuracy -- Detection Experiment
Physics -- Congresses
530.5 - Journal URLs:
- http://www.iop.org/EJ/journal/1742-6596 ↗
http://ioppublishing.org/ ↗ - DOI:
- 10.1088/1742-6596/2449/1/012045 ↗
- Languages:
- English
- ISSNs:
- 1742-6588
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5036.223000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 26037.xml