Effective optimization strategy for large optimization volume object, remaining volume at risk (RVR): α-value selection and usage from generalized equivalent uniform dose (gEUD) curve deviation perspective. (23rd February 2023)
- Record Type:
- Journal Article
- Title:
- Effective optimization strategy for large optimization volume object, remaining volume at risk (RVR): α-value selection and usage from generalized equivalent uniform dose (gEUD) curve deviation perspective. (23rd February 2023)
- Main Title:
- Effective optimization strategy for large optimization volume object, remaining volume at risk (RVR): α-value selection and usage from generalized equivalent uniform dose (gEUD) curve deviation perspective
- Authors:
- Anetai, Yusuke
Takegawa, Hideki
Koike, Yuhei
Nakamura, Satoaki
Tanigawa, Noboru - Abstract:
- Abstract: Objective. A large optimization volume for intensity-modulated radiation therapy (IMRT), such as the remaining volume at risk (RVR), is traditionally unsuitable for dose-volume constraint control and requires planner-specific empirical considerations owing to the patient-specific shape. To enable less empirical optimization, the generalized equivalent uniform dose (gEUD) optimization is effective; however, the utilization of parameter a -values remains elusive. Our study clarifies the a -value characteristics for optimization and to enable effective a -value use. Approach. The gEUD can be obtained as a function of its a -value, which is the weighted generalized mean; its curve has a continuous, differentiable, and sigmoid shape, deforming in its optimization state with retained curve characteristics. Using differential geometry, the gEUD curve changes in optimization is considered a geodesic deviation intervened by the forces between deforming and retaining the curve. The curvature and gradient of the curve are radically related to optimization. The vertex point ( a = a k ) was set and the a -value roles were classified into the following three parts of the curve with respect to the a -value: (i) high gradient and middle curvature, (ii) middle gradient and high curvature, and (iii) low gradient and low curvature. Then, a strategy for multiple a -values was then identified using RVR optimization. Main results. Eleven head and neck patients who underwent staticAbstract: Objective. A large optimization volume for intensity-modulated radiation therapy (IMRT), such as the remaining volume at risk (RVR), is traditionally unsuitable for dose-volume constraint control and requires planner-specific empirical considerations owing to the patient-specific shape. To enable less empirical optimization, the generalized equivalent uniform dose (gEUD) optimization is effective; however, the utilization of parameter a -values remains elusive. Our study clarifies the a -value characteristics for optimization and to enable effective a -value use. Approach. The gEUD can be obtained as a function of its a -value, which is the weighted generalized mean; its curve has a continuous, differentiable, and sigmoid shape, deforming in its optimization state with retained curve characteristics. Using differential geometry, the gEUD curve changes in optimization is considered a geodesic deviation intervened by the forces between deforming and retaining the curve. The curvature and gradient of the curve are radically related to optimization. The vertex point ( a = a k ) was set and the a -value roles were classified into the following three parts of the curve with respect to the a -value: (i) high gradient and middle curvature, (ii) middle gradient and high curvature, and (iii) low gradient and low curvature. Then, a strategy for multiple a -values was then identified using RVR optimization. Main results. Eleven head and neck patients who underwent static seven-field IMRT were used to verify the a -value characteristics and curvature effect for optimization. The lower a -value (i) ( a = 1–3) optimization was effective for the whole dose-volume range; in contrast, the effect of higher a -value (iii) ( a = 12–20) optimization addressed strongly the high-dose range of the dose volume. The middle a -value (ii) (around a = a k ) showed intermediate but effective high-to-low dose reduction. These a -value characteristics were observed as superimpositions in the optimization. Thus, multiple gEUD-based optimization was significantly superior to the exponential constraints normally applied to the RVR that surrounds the PTV, normal tissue objective (NTO), resulting in up to 25.9% and 8.1% improvement in dose-volume indices D2% and V10Gy, respectively. Significance. This study revealed an appropriate a -value for gEUD optimization, leading to favorable dose-volume optimization for the RVR region using fixed multiple a -value conditions, despite the very large and patient-specific shape of the region. … (more)
- Is Part Of:
- Physics in medicine & biology. Volume 68:Number 5(2023)
- Journal:
- Physics in medicine & biology
- Issue:
- Volume 68:Number 5(2023)
- Issue Display:
- Volume 68, Issue 5 (2023)
- Year:
- 2023
- Volume:
- 68
- Issue:
- 5
- Issue Sort Value:
- 2023-0068-0005-0000
- Page Start:
- Page End:
- Publication Date:
- 2023-02-23
- Subjects:
- generalized equivalent uniform dose -- optimization force -- RVR optimization -- a-value of gEUD -- intensity modulated radiation therapy -- planning of IMRT -- differential geometry
Biophysics -- Periodicals
Medical physics -- Periodicals
610.153 - Journal URLs:
- http://ioppublishing.org/ ↗
http://iopscience.iop.org/0031-9155 ↗ - DOI:
- 10.1088/1361-6560/acb989 ↗
- Languages:
- English
- ISSNs:
- 0031-9155
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 26027.xml