Consensus recommendations for a standardized Brain Tumor Imaging Protocol in clinical trials. Issue 9 (6th August 2015)
- Record Type:
- Journal Article
- Title:
- Consensus recommendations for a standardized Brain Tumor Imaging Protocol in clinical trials. Issue 9 (6th August 2015)
- Main Title:
- Consensus recommendations for a standardized Brain Tumor Imaging Protocol in clinical trials
- Authors:
- Ellingson, Benjamin M.
Bendszus, Martin
Boxerman, Jerrold
Barboriak, Daniel
Erickson, Bradley J.
Smits, Marion
Nelson, Sarah J.
Gerstner, Elizabeth
Alexander, Brian
Goldmacher, Gregory
Wick, Wolfgang
Vogelbaum, Michael
Weller, Michael
Galanis, Evanthia
Kalpathy-Cramer, Jayashree
Shankar, Lalitha
Jacobs, Paula
Pope, Whitney B.
Yang, Dewen
Chung, Caroline
Knopp, Michael V.
Cha, Soonme
van den Bent, Martin J.
Chang, Susan
Al Yung, W.K.
Cloughesy, Timothy F.
Wen, Patrick Y.
Gilbert, Mark R.
Whitney, Andrew
Sandak, David
Musella, Al
Haynes, Chas
Wallace, Max
Arons, David F.
Kingston, Ann
Sul, Joohee
Krainak, Daniel
… (more) - Abstract:
- Abstract: A recent joint meeting was held on January 30, 2014, with the US Food and Drug Administration (FDA), National Cancer Institute (NCI), clinical scientists, imaging experts, pharmaceutical and biotech companies, clinical trials cooperative groups, and patient advocate groups to discuss imaging endpoints for clinical trials in glioblastoma. This workshop developed a set of priorities and action items including the creation of a standardized MRI protocol for multicenter studies. The current document outlines consensus recommendations for a standardized Brain Tumor Imaging Protocol (BTIP), along with the scientific and practical justifications for these recommendations, resulting from a series of discussions between various experts involved in aspects of neuro-oncology neuroimaging for clinical trials. The minimum recommended sequences include: (i) parameter-matched precontrast and postcontrast inversion recovery-prepared, isotropic 3D T1-weighted gradient-recalled echo; (ii) axial 2D T2-weighted turbo spin-echo acquired after contrast injection and before postcontrast 3D T1-weighted images to control timing of images after contrast administration; (iii) precontrast, axial 2D T2-weighted fluid-attenuated inversion recovery; and (iv) precontrast, axial 2D, 3-directional diffusion-weighted images. Recommended ranges of sequence parameters are provided for both 1.5 T and 3 T MR systems.
- Is Part Of:
- Neuro-oncology. Volume 17:Issue 9(2015:Sep.)
- Journal:
- Neuro-oncology
- Issue:
- Volume 17:Issue 9(2015:Sep.)
- Issue Display:
- Volume 17, Issue 9 (2015)
- Year:
- 2015
- Volume:
- 17
- Issue:
- 9
- Issue Sort Value:
- 2015-0017-0009-0000
- Page Start:
- 1188
- Page End:
- 1198
- Publication Date:
- 2015-08-06
- Subjects:
- Brain Tumor Imaging Protocol -- clinical trials -- glioblastoma -- MRI
Brain Neoplasms -- Periodicals
Brain -- Tumors -- Periodicals
Brain -- Cancer -- Periodicals
Nervous system -- Cancer -- Periodicals
616.99481 - Journal URLs:
- http://neuro-oncology.dukejournals.org/ ↗
http://neuro-oncology.oxfordjournals.org/ ↗
http://www.oxfordjournals.org/content?genre=journal&issn=1522-8517 ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/neuonc/nov095 ↗
- Languages:
- English
- ISSNs:
- 1522-8517
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6081.288000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 26021.xml