Intraoperative Cardiac Ultrasound Examination Using Vector Flow Imaging. (October 2013)
- Record Type:
- Journal Article
- Title:
- Intraoperative Cardiac Ultrasound Examination Using Vector Flow Imaging. (October 2013)
- Main Title:
- Intraoperative Cardiac Ultrasound Examination Using Vector Flow Imaging
- Authors:
- Hansen, Kristoffer Lindskov
Pedersen, Mads Møller
Møller-Sørensen, Hasse
Kjaergaard, Jesper
Nilsson, Jens Christian
Lund, Jens Teglgaard
Jensen, Jørgen Arendt
Nielsen, Michael Bachmann - Abstract:
- Conventional ultrasound (US) methods for blood velocity estimation only provide one-dimensional and angle-dependent velocity estimates; thus, the complexity of cardiac flow has been difficult to measure. To circumvent these limitations, the Transverse Oscillation (TO) vector flow method has been proposed. The vector flow method implemented on a commercial scanner provided real-time, angle-independent estimates of cardiac blood flow. Epicardiac and epiaortic, intraoperative US examinations were performed on three patients with stenosed coronary arteries scheduled for bypass surgery. Repeating cyclic beat-to-beat flow patterns were seen in the ascending aorta and pulmonary artery of each patient, but these patterns varied between patients. Early systolic retrograde flow filling the aortic sinuses was seen in the ascending aorta as well as early systolic retrograde flow in the pulmonary artery. In diastole, stable vortices in aortic sinuses of the ascending aorta created central antegrade flow. A stable vortex in the right atrium was seen during the entire heart cycle. The measurements were compared with estimates obtained intraoperatively with conventional spectral Doppler US using a transesophageal and an epiaortic approach. Mean differences in peak systole velocity of 11% and 26% were observed when TO was compared with transesophageal echocardiography and epiaortic US, respectively. In one patient, the cardiac output derived from vector velocities was compared with pulmonaryConventional ultrasound (US) methods for blood velocity estimation only provide one-dimensional and angle-dependent velocity estimates; thus, the complexity of cardiac flow has been difficult to measure. To circumvent these limitations, the Transverse Oscillation (TO) vector flow method has been proposed. The vector flow method implemented on a commercial scanner provided real-time, angle-independent estimates of cardiac blood flow. Epicardiac and epiaortic, intraoperative US examinations were performed on three patients with stenosed coronary arteries scheduled for bypass surgery. Repeating cyclic beat-to-beat flow patterns were seen in the ascending aorta and pulmonary artery of each patient, but these patterns varied between patients. Early systolic retrograde flow filling the aortic sinuses was seen in the ascending aorta as well as early systolic retrograde flow in the pulmonary artery. In diastole, stable vortices in aortic sinuses of the ascending aorta created central antegrade flow. A stable vortex in the right atrium was seen during the entire heart cycle. The measurements were compared with estimates obtained intraoperatively with conventional spectral Doppler US using a transesophageal and an epiaortic approach. Mean differences in peak systole velocity of 11% and 26% were observed when TO was compared with transesophageal echocardiography and epiaortic US, respectively. In one patient, the cardiac output derived from vector velocities was compared with pulmonary artery catheter thermodilution technique and showed a difference of 16%. Vector flow provides real-time, angle-independent vector velocities of cardiac blood flow. The technique can potentially reveal new information of cardiovascular physiology and give insight into blood flow dynamics. … (more)
- Is Part Of:
- Ultrasonic imaging. Volume 35:Number 4(2013)
- Journal:
- Ultrasonic imaging
- Issue:
- Volume 35:Number 4(2013)
- Issue Display:
- Volume 35, Issue 4 (2013)
- Year:
- 2013
- Volume:
- 35
- Issue:
- 4
- Issue Sort Value:
- 2013-0035-0004-0000
- Page Start:
- 318
- Page End:
- 332
- Publication Date:
- 2013-10
- Subjects:
- ultrasound -- vector flow imaging -- cardiac imaging -- blood flow -- Transverse Oscillation
Diagnostic ultrasonic imaging -- Methodology -- Periodicals
Ultrasonic testing -- Periodicals
Ultrasonic imaging -- Periodicals
Ultrasonography -- Periodicals
Échographie -- Méthodologie -- Périodiques
Essais par ultrasons -- Périodiques
Imagerie ultrasonore -- Périodiques
616.07543 - Journal URLs:
- http://uix.sagepub.com/ ↗
http://www.sciencedirect.com/science/journal/01617346 ↗
http://www.sagepublications.com/ ↗
http://www.idealibrary.com ↗ - DOI:
- 10.1177/0161734613505552 ↗
- Languages:
- English
- ISSNs:
- 0161-7346
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 26020.xml